CVE-2026-100613 — capgo.app Authorization Bypass via Stale Channel Permission Overrides
capgo.app is an over-the-air (OTA) update platform for Capacitor apps. In all versions up to and including the current release (no patch available at time of publication), the `transfer_app()` database function transfers an app, its channels, versions and related records to a destination organization without deleting or revalidating existing rows in `channel_permission_overrides`. As a result, a user who legitimately held a channel permission override while a member of the source organization retains that override after the transfer, even though they have no membership and no RBAC binding in the destination organization. Using their own authenticated JWT against the PostgREST API, such a former member can modify the destination-owned channel to point at a different bundle, causing the /updates endpoint to serve an attacker-selected application version to devices. The previously proposed fix for GHSA-626c-p6fq-3whq (PR #3093), which validates organization membership when an override is created or updated, does not remove overrides that became stale as a result of an app transfer.
Descrição oficial em inglês (tradução ainda não revisada).
Quem explora e qual a prioridade
Nota de 0 a 100 que combina exploração confirmada, uso por ransomware e grupos APT, exploits públicos, EPSS e severidade.
Como a nota foi calculada
- EPSS 0.2% (probabilidade de exploração em 30 dias)+1
- Severidade técnica (medium)+3
- CISA SSVC: exploração "poc"+5
A nota ordena a fila de correção; não substitui o contexto dos seus ativos (exposição à internet, criticidade, compensações).
Triagem
Está sendo explorada, qual a probabilidade de exploração, o que afeta e qual a severidade segundo as fontes.
Avaliação SSVC da CISA CISA
Três pontos de decisão que a CISA publica para as CVEs que avalia (SSVC 2.0.3). Uma decisão de priorização, não uma nota de severidade.
Remediação
Correções e mitigações documentadas pelas fontes — com link para o aviso original.
Nenhuma correção documentada pelas fontes consultadas. Isso não significa que não exista: verifique o aviso do fabricante.
Primeiras 24 horas
Ordenado a partir dos próprios campos do registro — exposição primeiro, porque não se corrige o que não se encontrou. Ponto de partida, gerado por regras.
- Identifique ativos expostos que executam as combinações de fabricante/produto/versão afetadas (Capgo Capgo.app).
- Nenhuma correção documentada nas fontes: reduza a exposição e monitore o aviso do fabricante.
- Procure nos logs disponíveis sinais de tentativa de exploração compatíveis com a classe da falha (controle de acesso), erros e anomalias de autenticação.
Escopo afetado
Fabricante, produto e versões como as fontes os descrevem.
Características do ataque
O vetor CVSS decodificado. Descreve o ataque, não a sua exposição a ele.
Todas as pontuações coletadas
As fontes pontuam de forma independente e podem discordar; cada linha diz quem pontuou e em qual versão.
| Nota | Versão | Severidade | Explor. | Impacto | Pontuado por |
|---|---|---|---|---|---|
| 6.0 | CVSS 4.0 | Média | — | — | disclosure@vulncheck.com via NIST National Vulnerability Database |
| 6.0 | CVSS 4.0 | Média | — | — | VulnCheck via CVE Program (cve.org) e CISA ADP |
| 5.3 | CVSS 3.1 | Média | 1.6 | 3.6 | disclosure@vulncheck.com via NIST National Vulnerability Database |
| 5.3 | CVSS 3.1 | Média | — | — | VulnCheck via CVE Program (cve.org) e CISA ADP |
CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:N (nota exibida no topo: disclosure@vulncheck.com) Fraqueza MITRE
Classe de fraqueza segundo o catálogo CWE do MITRE.
Detecção
Derivado do vetor CVSS e da classe da fraqueza. Pontos de partida, não regras testadas.
- Priorize telemetria de borda para o componente exposto na rede (proxy, WAF, IDS/IPS).
- Audite ações administrativas e acessos a recursos fora do padrão do usuário.
Linha do tempo
O que aconteceu com esta CVE, do mais recente ao mais antigo.
- 2026
- Produtos afetados adicionados · cap-go/capgo.app
- Avaliação SSVC atualizada
- Ficha publicada
- CVSS alterado · 5.3
- Status na fonte alterado · → Deferred
- Registro criado nesta base
- CVE publicada
Atividade das fontes
Leituras que se repetem foram contadas em vez de listadas.
- 1× Descrição oficial atualizada · 15/10/2026 – 15/10/2026
Referências
2 no registro
Em outras páginas do site
CVEs relacionadas (mesmos produtos)
- Média CVE-2026-100629 Capgo backend before 12.127.5 Privilege Escalation via role_bindings PATCH 20 d
- Média CVE-2026-100621 capgo.app Content-Lock Bypass via r2-direct Bundle Mutation 20 d
- Alta CVE-2026-100622 capgo.app through 12.129.0 Cache Restoration of Deleted Bundles 20 d
- Alta CVE-2026-100623 Capgo Authentication Bypass via Direct PostgREST org_users Table Write 20 d
- Média CVE-2026-100624 Capgo.app before 12.264.5 Upload Expiry Bypass via build upload 20 d
- Média CVE-2026-100626 capgo through 12.128.2 IDOR via PUT /app icon endpoint 20 d
Não consta em nenhuma fonte consultada
Listado em vez de deixado em branco: um campo vazio e um não medido parecem iguais na tela, e só um deles é motivo para procurar em outro lugar.
- Nenhuma versão corrigida, patch ou mitigação documentada.
- Nenhum IOC confirmado (IPs, domínios, hashes ou artefatos de malware) fornecido.
- Nenhum inventário de ativos, controle compensatório ou evidência de implantação de patch da sua organização.
- Nenhuma captura de tráfego de exploração, amostra de log ou caso de incidente.
Respondido a partir deste registro
Texto montado apenas com os campos acima — sem afirmações adicionais.
O que os defensores devem saber primeiro?
CVE-2026-100613 é "capgo.app Authorization Bypass via Stale Channel Permission Overrides", de severidade Média. Afeta Capgo.app (Capgo); as versões estão na tabela de escopo. Não está na CISA KEV, o que não exclui exploração. CVSS 5.3 descreve a severidade técnica. EPSS 0.21% estima a probabilidade de exploração em 30 dias; nenhum dos dois substitui o contexto dos seus ativos. Verifique primeiro se ativos expostos ou críticos executam as versões afetadas, aplique as correções ou mitigações do fabricante e preserve logs para análise.
Comentários
Discussão técnica moderada. Leia as regras da comunidade.
Nenhum comentário ainda.
Entre ou crie uma conta para comentar e sugerir correções.