CVE-2026-50201 — Steeltoe's sensitive actuators (heapdump/env) only require Restricted permission
Steeltoe is an open source project that provides a collection of libraries that helps users build cloud-native applications. In Steeltoe.Management.Endpoint prior to version 4.2.0 and Steeltoe.Management.EndpointCore prior to version 3.4.0, all Steeltoe actuator endpoints default to `EndpointPermissions.Restricted`, which is mappeds to Cloud Foundry's `read_basic_data` permission (granted to Space Auditors and similar low-trust roles). Sensitive actuators including heap dump, environment, and thread dump do not raise this to `EndpointPermissions.Full`, so CF's `read_sensitive_data` permission flag is not enforced for those endpoints. Spring Boot's equivalent Cloud Foundry integration gates these endpoints with `read_sensitive_data` by default. Steeltoe.Management.Endpoint 4.2.0 and Steeltoe.Management.EndpointCore 3.4.0 patch the issue. If an immediate upgrade is not possible, explicitly set `RequiredPermissions = EndpointPermissions.Full` in the options for `HeapDumpEndpointOptions`, `EnvironmentEndpointOptions`, and `ThreadDumpEndpointOptions`; and/or if heap dump, thread dump, or environment are not needed in production, register only the required actuators individually instead of using `AddAllActuators()`.
Descrição oficial em inglês (tradução ainda não revisada).
Quem explora e qual a prioridade
Nota de 0 a 100 que combina exploração confirmada, uso por ransomware e grupos APT, exploits públicos, EPSS e severidade.
Como a nota foi calculada
- EPSS 0.4% (probabilidade de exploração em 30 dias)+5
- Severidade técnica (medium)+3
A nota ordena a fila de correção; não substitui o contexto dos seus ativos (exposição à internet, criticidade, compensações).
Triagem
Está sendo explorada, qual a probabilidade de exploração, o que afeta e qual a severidade segundo as fontes.
Avaliação SSVC da CISA CISA
Três pontos de decisão que a CISA publica para as CVEs que avalia (SSVC 2.0.3). Uma decisão de priorização, não uma nota de severidade.
Remediação
Correções e mitigações documentadas pelas fontes — com link para o aviso original.
Nenhuma correção documentada pelas fontes consultadas. Isso não significa que não exista: verifique o aviso do fabricante.
Primeiras 24 horas
Ordenado a partir dos próprios campos do registro — exposição primeiro, porque não se corrige o que não se encontrou. Ponto de partida, gerado por regras.
- Identifique ativos expostos que executam as combinações de fabricante/produto/versão afetadas (SteeltoeOSS Steeltoe.Management.Endpoint, SteeltoeOSS Steeltoe.Management.EndpointBase).
- Nenhuma correção documentada nas fontes: reduza a exposição e monitore o aviso do fabricante.
- Procure nos logs disponíveis sinais de tentativa de exploração compatíveis com a classe da falha (escalonamento de privilégio), erros e anomalias de autenticação.
Escopo afetado
Fabricante, produto e versões como as fontes os descrevem.
| Fabricante | Produto | Versões | Status | Fonte |
|---|---|---|---|---|
| SteeltoeOSS | Steeltoe.Management.Endpoint | versão < 4.2.0 | Vulnerável | CVE Program (cve.org) e CISA ADP |
| SteeltoeOSS | Steeltoe.Management.EndpointBase | versão < 3.4.0 | Vulnerável | CVE Program (cve.org) e CISA ADP |
Características do ataque
O vetor CVSS decodificado. Descreve o ataque, não a sua exposição a ele.
Todas as pontuações coletadas
As fontes pontuam de forma independente e podem discordar; cada linha diz quem pontuou e em qual versão.
| Nota | Versão | Severidade | Explor. | Impacto | Pontuado por |
|---|---|---|---|---|---|
| 6.5 | CVSS 3.1 | Média | 2.8 | 3.6 | security-advisories@github.com via NIST National Vulnerability Database |
| 6.5 | CVSS 3.1 | Média | — | — | GitHub_M via CVE Program (cve.org) e CISA ADP |
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N (nota exibida no topo: security-advisories@github.com) Fraqueza MITRE
Classe de fraqueza segundo o catálogo CWE do MITRE.
EPSS ao longo do tempo FIRST
13/10/2026 → 14/10/2026 · 2 leitura(s) · máximo 0.40%
Detecção
Derivado do vetor CVSS e da classe da fraqueza. Pontos de partida, não regras testadas.
- Priorize telemetria de borda para o componente exposto na rede (proxy, WAF, IDS/IPS).
Linha do tempo
O que aconteceu com esta CVE, do mais recente ao mais antigo.
- 2026
- Produtos afetados adicionados · steeltoeoss/steeltoe.management.endpoint, steeltoeoss/steeltoe.management.endpointbase
- Avaliação SSVC atualizada
- Ficha publicada
- CVSS alterado · 6.5
- Status na fonte alterado · → Deferred
- Registro criado nesta base
- CVE publicada
Atividade das fontes
Leituras que se repetem foram contadas em vez de listadas.
- 1× Descrição oficial atualizada · 13/10/2026 – 13/10/2026
Referências
3 no registro
Em outras páginas do site
CVEs relacionadas (mesmos produtos)
- Alta CVE-2026-50200 Steeltoe's env sanitizer misses connection strings — leaks embedded DB passwords 17/06/2026
- Alta CVE-2026-50194 Steeltoe vulnerable to management-port isolation bypass via spoofed Host header 17/06/2026
Não consta em nenhuma fonte consultada
Listado em vez de deixado em branco: um campo vazio e um não medido parecem iguais na tela, e só um deles é motivo para procurar em outro lugar.
- Nenhuma versão corrigida, patch ou mitigação documentada.
- Nenhum IOC confirmado (IPs, domínios, hashes ou artefatos de malware) fornecido.
- Nenhum inventário de ativos, controle compensatório ou evidência de implantação de patch da sua organização.
- Nenhuma captura de tráfego de exploração, amostra de log ou caso de incidente.
Respondido a partir deste registro
Texto montado apenas com os campos acima — sem afirmações adicionais.
O que os defensores devem saber primeiro?
CVE-2026-50201 é "Steeltoe's sensitive actuators (heapdump/env) only require Restricted permission", de severidade Média. Afeta Steeltoe.Management.Endpoint (SteeltoeOSS); as versões estão na tabela de escopo. Não está na CISA KEV, o que não exclui exploração. CVSS 6.5 descreve a severidade técnica. EPSS 0.40% estima a probabilidade de exploração em 30 dias; nenhum dos dois substitui o contexto dos seus ativos. Verifique primeiro se ativos expostos ou críticos executam as versões afetadas, aplique as correções ou mitigações do fabricante e preserve logs para análise.
Comentários
Discussão técnica moderada. Leia as regras da comunidade.
Nenhum comentário ainda.
Entre ou crie uma conta para comentar e sugerir correções.