CVE-2026-70386 — OnePlus OxygenOS improper neutralization of special elements vulnerability

Improper neutralization of special elements used in an OS command ('OS command injection') and Missing Authorization vulnerability in OnePlus OxygenOS on Android. Any locally installed Android application, with no permissions declared and no user interaction beyond launching it, can execute arbitrary shell commands as uid 0 in the u:r:dumpstate:s0 SELinux domain. Two defects combine: (a) OnePlus's atlasservice binder interface accepts setEvent(String8 name, String8 value) from any caller without authorization, and (b) one event handler (OplusAtlasLogWriter::handleEvent, matching event name atlas_event_multimedia_audio_dumpsys) copies the caller-supplied value into the system property oplus.audio.dumpinfo.type and starts the root init service audiodumpinfo, which passes that property value unsanitized to system(). This issue affects OxygenOS: from 16.1.0 before 16.1.10.500, from 16.0.0 before 16.0.5.1200, and from 15.0.0 before 15.0.0.2000.

Descrição oficial em inglês (tradução ainda não revisada).

Publicada em 21/10/2026 · Atualizada em 22/10/2026 · Fontes: NIST National Vulnerability Database, CVE Program (cve.org) e CISA ADP, GitHub Security Advisories · CNA: ENISA

Quem explora e qual a prioridade

Nota de 0 a 100 que combina exploração confirmada, uso por ransomware e grupos APT, exploits públicos, EPSS e severidade.

Nenhum sinal de exploração nas fontes consultadas até agora.
Como a nota foi calculada
  • EPSS 1.2% (probabilidade de exploração em 30 dias)+10
  • Severidade técnica (high)+6

A nota ordena a fila de correção; não substitui o contexto dos seus ativos (exposição à internet, criticidade, compensações).

Triagem

Está sendo explorada, qual a probabilidade de exploração, o que afeta e qual a severidade segundo as fontes.

Exploração
Não confirmada
Fora da CISA KEV — ausência de registro, não prova de que não é explorada.
EPSS FIRST
1,22%
à frente de 68% das CVEs pontuadas · 26/10/2026
Afeta
OnePlus
OxygenOS
CVSS base
8.5
Alta · 2 fonte(s)

Remediação

Correções e mitigações documentadas pelas fontes — com link para o aviso original.

Nenhuma correção documentada pelas fontes consultadas. Isso não significa que não exista: verifique o aviso do fabricante.

Primeiras 24 horas

Ordenado a partir dos próprios campos do registro — exposição primeiro, porque não se corrige o que não se encontrou. Ponto de partida, gerado por regras.

  1. Identifique ativos expostos que executam as combinações de fabricante/produto/versão afetadas (OnePlus OxygenOS).
  2. Nenhuma correção documentada nas fontes: reduza a exposição e monitore o aviso do fabricante.
  3. Procure nos logs disponíveis sinais de tentativa de exploração compatíveis com a classe da falha (injeção), erros e anomalias de autenticação.

Escopo afetado

Fabricante, produto e versões como as fontes os descrevem.

FabricanteProdutoVersõesStatusFonte
OnePlus OxygenOS ≥ 16.0.0 e < 16.0.5.1200≥ 15.0.0 e < 15.0.0.2000 Vulnerável CVE Program (cve.org) e CISA ADP

Características do ataque

O vetor CVSS decodificado. Descreve o ataque, não a sua exposição a ele.

Vetor de ataque
Local
Complexidade
Baixa
Requisitos de ataque
Nenhum
Privilégios exigidos
Baixos
Interação do usuário
Nenhuma
Escopo
X
Confidencialidade (sistema vulnerável)
Alto
Integridade (sistema vulnerável)
Alto
Disponibilidade (sistema vulnerável)
Alto
Confidencialidade (subsequente)
Nenhum
Integridade (subsequente)
Nenhum
Disponibilidade (subsequente)
Nenhum

Todas as pontuações coletadas

As fontes pontuam de forma independente e podem discordar; cada linha diz quem pontuou e em qual versão.

NotaVersãoSeveridadeExplor.ImpactoPontuado por
8.5 CVSS 4.0 Alta — — a6d3dc9e-0591-4a13-bce7-0f5b31ff6158 via NIST National Vulnerability Database
8.5 CVSS 4.0 Alta — — ENISA via CVE Program (cve.org) e CISA ADP
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X (nota exibida no topo: a6d3dc9e-0591-4a13-bce7-0f5b31ff6158)

Fraqueza MITRE

Classe de fraqueza segundo o catálogo CWE do MITRE.

CWE-78 · OS Command Injection

Outras CVEs com esta fraqueza →

EPSS ao longo do tempo FIRST

21/10/2026 → 26/10/2026 · 6 leitura(s) · máximo 1.22%

Detecção

Derivado do vetor CVSS e da classe da fraqueza. Pontos de partida, não regras testadas.

  • Vetor local/físico: concentre-se em telemetria de endpoint (EDR) dos hosts afetados.
  • Procure parâmetros com metacaracteres de comando/consulta e processos filhos inesperados do serviço.
telemetria de endpoint (EDR)logs da aplicação

Linha do tempo

O que aconteceu com esta CVE, do mais recente ao mais antigo.

  • 2026
  • Status na fonte alterado · Received → Deferred
    22/10/2026 · NIST National Vulnerability Database
  • Produtos afetados removidos · 1
    22/10/2026 · CVE Program (cve.org) e CISA ADP
  • Produtos afetados adicionados · oneplus/oxygenos
    21/10/2026 · CVE Program (cve.org) e CISA ADP
  • Ficha publicada
    21/10/2026
  • CVSS alterado · 8.5
    21/10/2026 · NIST National Vulnerability Database
  • Status na fonte alterado · → Received
    21/10/2026 · NIST National Vulnerability Database
  • Registro criado nesta base
    21/10/2026 · Alertas do Telegram
  • CVE publicada
    21/10/2026 · ENISA

Atividade das fontes

Leituras que se repetem foram contadas em vez de listadas.

  • 2× Referências adicionadas · 21/10/2026 – 22/10/2026
  • 1× Descrição oficial atualizada · 21/10/2026 – 21/10/2026

Referências

4 no registro

Em outras páginas do site

OnePlus
todas as CVEs deste fabricante
Injeção
mesma classe
CWE-78
outras páginas com esta fraqueza

CVEs relacionadas (mesmos produtos)

  • Alta CVE-2026-70387 OnePlus OxygenOS exposed dangerous method vulnerability 6 d
  • Alta CVE-2025-10184 OnePlus OxygenOS Telephony provider permission bypass 23/09/2025

Não consta em nenhuma fonte consultada

Listado em vez de deixado em branco: um campo vazio e um não medido parecem iguais na tela, e só um deles é motivo para procurar em outro lugar.

  • Nenhuma versão corrigida, patch ou mitigação documentada.
  • Sem avaliação SSVC da CISA.
  • Nenhum IOC confirmado (IPs, domínios, hashes ou artefatos de malware) fornecido.
  • Nenhum inventário de ativos, controle compensatório ou evidência de implantação de patch da sua organização.
  • Nenhuma captura de tráfego de exploração, amostra de log ou caso de incidente.

Respondido a partir deste registro

Texto montado apenas com os campos acima — sem afirmações adicionais.

O que os defensores devem saber primeiro?

CVE-2026-70386 é "OnePlus OxygenOS improper neutralization of special elements vulnerability", de severidade Alta. Afeta OxygenOS (OnePlus); as versões estão na tabela de escopo. Não está na CISA KEV, o que não exclui exploração. CVSS 8.5 descreve a severidade técnica. EPSS 1.22% estima a probabilidade de exploração em 30 dias; nenhum dos dois substitui o contexto dos seus ativos. Verifique primeiro se ativos expostos ou críticos executam as versões afetadas, aplique as correções ou mitigações do fabricante e preserve logs para análise.

Comentários

Discussão técnica moderada. Leia as regras da comunidade.

Nenhum comentário ainda.

Entre ou crie uma conta para comentar e sugerir correções.