CVE Intelligence
Alta

CVE-2026-82750 — Unbounded EIP-7702 authorization list in mpp Tempo fee-payer sponsorship inflates gas cost and sponsors account delegation

Improper Validation of Specified Quantity in Input in ZenHive mpp allows an unauthenticated remote client to inflate the fee-payer's gas cost per sponsored payment by a large multiplier and to have the sponsor pay for EIP-7702 account delegations of the client's choosing. When the server sponsors Tempo payments, MPP.Methods.Tempo.FeePayerPolicy.measure/3 in lib/mpp/methods/tempo/fee_payer_policy.ex bounds the gas fields, the fee budget, the validity window and the access list of the client-signed 0x76 envelope, but never reads its aa_authorization_list field. Every signed delegation in that list is charged as intrinsic gas before the payment call runs, so a client attaching delegations from throwaway authority keys makes the sponsor pay for them within the default gas_limit ceiling. At the reporter's default of seven entries the sponsored cost rises from about 46,575 gas to about 1,884,087 gas. Because each entry is applied as a persistent set-code delegation, a client can also upgrade its own accounts to delegated code at the sponsor's expense. This issue affects mpp: from 0.2.0 before 0.16.1.

Descrição oficial em inglês (tradução ainda não revisada).

Publicada em 06/09/2026 · Atualizada em 15/10/2026 · Fontes: NIST National Vulnerability Database, CVE Program (cve.org) e CISA ADP · CNA: EEF

Quem explora e qual a prioridade

Nota de 0 a 100 que combina exploração confirmada, uso por ransomware e grupos APT, exploits públicos, EPSS e severidade.

Nenhum sinal de exploração nas fontes consultadas até agora.
Como a nota foi calculada
  • Severidade técnica (high)+6

A nota ordena a fila de correção; não substitui o contexto dos seus ativos (exposição à internet, criticidade, compensações).

Triagem

Está sendo explorada, qual a probabilidade de exploração, o que afeta e qual a severidade segundo as fontes.

Exploração
Não confirmada
Fora da CISA KEV — ausência de registro, não prova de que não é explorada.
EPSS FIRST
—
Sem pontuação EPSS.
Afeta
Zenhive
Mpp
CVSS base
8.3
Alta · 2 fonte(s)

Avaliação SSVC da CISA CISA

Três pontos de decisão que a CISA publica para as CVEs que avalia (SSVC 2.0.3). Uma decisão de priorização, não uma nota de severidade.

Exploração
Nenhuma
nenhuma · prova de conceito · ativa
Automatizável
Não
se um atacante consegue automatizar as etapas da cadeia de ataque
Impacto técnico
Parcial
parcial · controle total do componente vulnerável

Remediação

Correções e mitigações documentadas pelas fontes — com link para o aviso original.

Nenhuma correção documentada pelas fontes consultadas. Isso não significa que não exista: verifique o aviso do fabricante.

Primeiras 24 horas

Ordenado a partir dos próprios campos do registro — exposição primeiro, porque não se corrige o que não se encontrou. Ponto de partida, gerado por regras.

  1. Identifique ativos expostos que executam as combinações de fabricante/produto/versão afetadas (Zenhive Mpp).
  2. O ataque é pela rede e não exige privilégios: restrinja a exposição (ACLs, VPN, WAF) até corrigir.
  3. Nenhuma correção documentada nas fontes: reduza a exposição e monitore o aviso do fabricante.
  4. Procure nos logs disponíveis sinais de tentativa de exploração, erros e anomalias de autenticação.

Escopo afetado

Fabricante, produto e versões como as fontes os descrevem.

FabricanteProdutoVersõesStatusFonte
Zenhive Mpp ≥ 0.2.0 e < 0.16.1≥ d29d54e507918db00a5b65d90136b73166c017d7 e < 0482572b47e1ffe1537ab80ab613d47b92833c2d Vulnerável CVE Program (cve.org) e CISA ADP

Características do ataque

O vetor CVSS decodificado. Descreve o ataque, não a sua exposição a ele.

Vetor de ataque
Rede
Complexidade
Baixa
Requisitos de ataque
Presentes
Privilégios exigidos
Nenhum
Interação do usuário
Nenhuma
Escopo
X
Confidencialidade (sistema vulnerável)
Nenhum
Integridade (sistema vulnerável)
Alto
Disponibilidade (sistema vulnerável)
Baixo
Confidencialidade (subsequente)
Nenhum
Integridade (subsequente)
Nenhum
Disponibilidade (subsequente)
Nenhum

Todas as pontuações coletadas

As fontes pontuam de forma independente e podem discordar; cada linha diz quem pontuou e em qual versão.

NotaVersãoSeveridadeExplor.ImpactoPontuado por
8.3 CVSS 4.0 Alta — — 6b3ad84c-e1a6-4bf7-a703-f496b71e49db via NIST National Vulnerability Database
8.3 CVSS 4.0 Alta — — EEF via CVE Program (cve.org) e CISA ADP
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X (nota exibida no topo: 6b3ad84c-e1a6-4bf7-a703-f496b71e49db)

Fraqueza MITRE

Classe de fraqueza segundo o catálogo CWE do MITRE.

CWE-1284

Outras CVEs com esta fraqueza →

Detecção

Derivado do vetor CVSS e da classe da fraqueza. Pontos de partida, não regras testadas.

  • Priorize telemetria de borda para o componente exposto na rede (proxy, WAF, IDS/IPS).
logs web/proxy/WAFIDS/IPS de rede

Linha do tempo

O que aconteceu com esta CVE, do mais recente ao mais antigo.

  • 2026
  • Produtos afetados adicionados · zenhive/mpp
    15/10/2026 · CVE Program (cve.org) e CISA ADP
  • Avaliação SSVC atualizada
    15/10/2026 · CVE Program (cve.org) e CISA ADP
  • Ficha publicada
    15/10/2026
  • CVSS alterado · 8.3
    15/10/2026 · NIST National Vulnerability Database
  • Status na fonte alterado · → Deferred
    15/10/2026 · NIST National Vulnerability Database
  • Registro criado nesta base
    15/10/2026 · NIST National Vulnerability Database
  • CVE publicada
    06/09/2026 · EEF

Atividade das fontes

Leituras que se repetem foram contadas em vez de listadas.

  • 1× Descrição oficial atualizada · 15/10/2026 – 15/10/2026

Referências

4 no registro

Em outras páginas do site

Zenhive
todas as CVEs deste fabricante
CWE-1284
outras páginas com esta fraqueza

CVEs relacionadas (mesmos produtos)

  • Alta CVE-2026-82751 Unbounded key authorization in mpp Tempo fee-payer sponsorship inflates gas cost and sponsors access-key provisioning 06/09/2026
  • Alta CVE-2026-73136 Static memo configuration in mpp Tempo disables per-challenge attribution binding, enabling third-party replay 19/08/2026
  • Alta CVE-2026-73541 Tempo fee sponsorship in mpp bounds each transaction but not aggregate exposure, allowing concurrent sponsor-wallet drain 19/08/2026
  • Baixa CVE-2026-73829 Non-atomic hash-credential dedup in mpp Tempo allows replay of a confirmed payment under a concurrent race 19/08/2026
  • Alta CVE-2026-67581 On-chain transfer proof is not single-use in mpp EVM payment method, enabling cross-challenge replay 19/08/2026
  • Alta CVE-2026-59695 Unbounded max_fee_per_gas in mpp Tempo fee-payer enables single-request wallet drain 17/07/2026

Não consta em nenhuma fonte consultada

Listado em vez de deixado em branco: um campo vazio e um não medido parecem iguais na tela, e só um deles é motivo para procurar em outro lugar.

  • Sem pontuação EPSS da FIRST.
  • Nenhuma versão corrigida, patch ou mitigação documentada.
  • Nenhum IOC confirmado (IPs, domínios, hashes ou artefatos de malware) fornecido.
  • Nenhum inventário de ativos, controle compensatório ou evidência de implantação de patch da sua organização.
  • Nenhuma captura de tráfego de exploração, amostra de log ou caso de incidente.

Respondido a partir deste registro

Texto montado apenas com os campos acima — sem afirmações adicionais.

O que os defensores devem saber primeiro?

CVE-2026-82750 é "Unbounded EIP-7702 authorization list in mpp Tempo fee-payer sponsorship inflates gas cost and sponsors account delegation", de severidade Alta. Afeta Mpp (Zenhive); as versões estão na tabela de escopo. Não está na CISA KEV, o que não exclui exploração. CVSS 8.3 descreve a severidade técnica. Verifique primeiro se ativos expostos ou críticos executam as versões afetadas, aplique as correções ou mitigações do fabricante e preserve logs para análise.

Comentários

Discussão técnica moderada. Leia as regras da comunidade.

Nenhum comentário ainda.

Entre ou crie uma conta para comentar e sugerir correções.