CVE Intelligence

Vulnerabilidades do Siemens SIMATIC S7-1500 Software Controller Linux V2

🔔 Criar alerta RSS Verificador de versão

CVEs publicadas que afetam Siemens SIMATIC S7-1500 Software Controller Linux V2: 12 registro(s), com versões afetadas e correções.

CVE-2026-63357 Média · 6.1 CWE-79 13/10/2026
Affected devices do not properly sanitize calculated signal data contained in imported calculated...
Affected devices do not properly sanitize calculated signal data contained in imported calculated signal files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.
CVE-2026-63356 Média · 6.1 CWE-79 13/10/2026
Cross-site Scripting (XSS) em Siemens SIMATIC Drive Controller CPU 1504D TF
Affected devices do not properly sanitize calculated signal names contained in imported CSV trace files before including them in error messages on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Attacker-controlled JavaScript could be executed in the user’s browser session when the resulting error message is displayed.
CVE-2026-63355 Média · 6.1 CWE-79 13/10/2026
Cross-site Scripting (XSS) em Siemens SIMATIC Drive Controller CPU 1504D TF
Affected devices do not properly sanitize signal names contained in imported CSV trace files before rendering them in selection menus on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Attacker-controlled JavaScript could be executed in the user’s browser session when the user subsequently interacts with an affected selection menu.
CVE-2026-63354 Crítica · 9.6 CWE-79 13/10/2026
Cross-site Scripting (XSS) em Siemens SIMATIC Drive Controller CPU 1504D TF
Affected devices do not properly validate and sanitize visual marker data contained in imported CSV trace files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.
CVE-2026-63353 Crítica · 9.6 CWE-79 13/10/2026
Affected devices do not properly sanitize comment fields contained in imported trace files before...
Affected devices do not properly sanitize comment fields contained in imported trace files before rendering them on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.
CVE-2026-63352 Média · 6.1 CWE-79 13/10/2026
Affected devices do not properly sanitize calculated signal data contained in imported CSV trace...
Affected devices do not properly sanitize calculated signal data contained in imported CSV trace files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.
CVE-2026-63351 Média · 6.1 CWE-79 13/10/2026
Cross-site Scripting (XSS) em Siemens SIMATIC Drive Controller CPU 1504D TF
Affected devices do not properly validate and sanitize visual properties of calculated signals contained in imported CSV trace files before rendering them on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.
CVE-2026-63350 Crítica · 9.6 CWE-95 13/10/2026
Eval Injection em Siemens SIMATIC Drive Controller CPU 1504D TF
Affected devices do not properly restrict executable content contained in imported trace files. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.
CVE-2026-25789 Alta · 7.1 CWE-79 12/05/2026
Cross-site Scripting (XSS) em Siemens SIMATIC Drive Controller CPU 1504D TF
Affected devices do not properly validate and sanitize filenames on the Firmware Update page. This could allow a remote attacker to social engineer the user into selecting the modified firmware file to be uploaded. This would result in malitcious JavaScript execution in the context of the authenticated user's session without requiring the file to be uploaded, potentially leading to session hijacking or credential theft.
CVE-2026-25787 Crítica · 9.1 CWE-79 12/05/2026
Cross-site Scripting (XSS) em Siemens SIMATIC Drive Controller CPU 1504D TF
Affected devices do not properly validate and sanitize Technology Object (TO) name rendered on the "Motion Control Diagnostics" page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the page. If a benign user with appropriate rights accesses the "Motion Control Diagnostics" parameters page, the malicious code would be executed in the scope of their web session.
CVE-2026-25786 Crítica · 9.1 CWE-79 12/05/2026
Cross-site Scripting (XSS) em Siemens SIMATIC Drive Controller CPU 1504D TF
Affected devices do not properly validate and sanitize PLC/station name rendered on the "communication" parameters page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the page. If a benign user with appropriate rights accesses the "communication" parameters page, the malicious code would be executed in the scope of their web session.
CVE-2025-40943 Crítica · 9.6 CWE-95 10/03/2026
Eval Injection em Siemens SIMATIC Drive Controller CPU 1504D TF
Affected devices do not properly sanitize contents of trace files. This could allow an attacker to inject code through social engineering an authorized user, who has the function right "Read diagnostics", to import a specially crafted trace file. The malicious trace file is insufficiently sanitized and malicious code could be executed in the clients browser session and trigger PLC operations via the webserver that the legitimate user is authorized to perform.