CVE Intelligence

Vulnerabilidades do Siemens Simcenter Femap

🔔 Criar alerta RSS Verificador de versão

CVEs publicadas que afetam Siemens Simcenter Femap: 15 registro(s), com versões afetadas e correções.
cpe:2.3:a:siemens:simcenter_femap

CVE-2026-59701 Alta · 7.8 CWE-125 11/08/2026
Out-of-bounds Read em Siemens Simcenter Femap
A vulnerability has been identified in Simcenter Femap (All versions < V2606.0001). The affected applications contains an out of bounds read vulnerability while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
CVE-2026-59700 Alta · 7.8 CWE-125 11/08/2026
Out-of-bounds Read em Siemens Simcenter Femap
A vulnerability has been identified in Simcenter Femap (All versions < V2606.0001). The affected applications contains an out of bounds read vulnerability while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
CVE-2026-59086 Alta · 7.8 CWE-121 11/08/2026
Stack-based Buffer Overflow em Siemens Simcenter Femap
A vulnerability has been identified in Simcenter Femap (All versions < V2606), Simcenter Nastran (All versions < V2606). The affected applications contain a stack overflow vulnerability while parsing specially strings as argument for one of the application binaries. This could allow an attacker to execute code in the context of the current process.
CVE-2025-12659 Alta · 7.8 CWE-122 12/05/2026
Heap-based buffer overflow in Siemens Simcenter Femap
Siemens Simcenter Femap contains a memory corruption vulnerability while parsing specially crafted IPT files. This could allow an attacker to execute code in the context of the current process.
CVE-2025-40745 Baixa · 3.7 CWE-295 14/04/2026
A vulnerability has been identified in Siemens Software Center (All versions < V3.5.8.2),...
A vulnerability has been identified in Siemens Software Center (All versions < V3.5.8.2), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Simcenter STAR-CCM+ (All versions < V2602), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Tecnomatix Plant Simulation (All versions < V2504.0008). Affected applications do not properly validate client certificates to connect to Analytics Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks.
CVE-2026-23720 Alta · 7.3 CWE-125 10/02/2026
Out-of-bounds Read em Siemens Simcenter Femap
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process.
CVE-2026-23719 Alta · 7.3 CWE-122 10/02/2026
Heap-based Buffer Overflow em Siemens Simcenter Femap
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process.
CVE-2026-23718 Alta · 7.3 CWE-125 10/02/2026
Out-of-bounds Read em Siemens Simcenter Femap
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process.
CVE-2026-23717 Alta · 7.3 CWE-125 10/02/2026
Out-of-bounds Read em Siemens Simcenter Femap
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process.
CVE-2026-23716 Alta · 7.3 CWE-125 10/02/2026
Out-of-bounds Read em Siemens Simcenter Femap
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process.
CVE-2026-23715 Alta · 7.3 CWE-787 10/02/2026
Out-of-bounds Write em Siemens Simcenter Femap
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds write vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process.
CVE-2025-40829 Alta · 7.8 CWE-908 12/12/2025
Use of Uninitialized Resource em Siemens Simcenter Femap
A vulnerability has been identified in Simcenter Femap (All versions < V2512). The affected applications contains an uninitialized memory vulnerability while parsing specially crafted SLDPRT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-27146)
CVE-2025-40801 Alta · 8.1 CWE-295 09/12/2025
Improper Certificate Validation em Siemens COMOS V10.6
A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), JT Bi-Directional Translator for STEP (All versions), NX V2412 (All versions < V2412.8900 with Cloud Entitlement (bundled as NX X)), NX V2506 (All versions < V2506.6000 with Cloud Entitlement (bundled as NX X)), Simcenter 3D (All versions < V2506.6000 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Femap (All versions < V2506.0002 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Studio (All versions < V2506.0001), Simcenter System Architect (All versions < V2506.0001), Tecnomatix Plant Simulation (All versions < V2504.0007). The SALT SDK is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.
CVE-2025-40800 Alta · 7.4 CWE-295 09/12/2025
Improper Certificate Validation em Siemens COMOS V10.6
A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), NX V2412 (All versions < V2412.8700), NX V2506 (All versions < V2506.6000), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Solid Edge SE2025 (All versions < V225.0 Update 10), Solid Edge SE2026 (All versions < V226.0 Update 1). The IAM client in affected products is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.
CVE-2025-40936 Alta · 7.8 CWE-125 17/11/2025
A vulnerability has been identified in PS/IGES Parasolid Translator Component (All versions < V29...
A vulnerability has been identified in PS/IGES Parasolid Translator Component (All versions < V29.0.258), Simcenter Femap (All versions < V2512.0003), Solid Edge (All versions < V226.00 Update 03). The affected applications contains an out of bounds read vulnerability while parsing specially crafted IGS files. This could allow an attacker to crash the application or execute code in the context of the current process. (ZDI-CAN-26755)