CVE Intelligence

Vulnerabilidades do Tenda AC7

🔔 Criar alerta RSS Verificador de versão

CVEs publicadas que afetam Tenda AC7: 8 registro(s), com versões afetadas e correções.

CVE-2026-4974 Alta · 8.8 CWE-787 27/03/2026
Tenda AC7 POST Request SetSysTimeCfg fromSetSysTime memory corruption
A flaw has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg of the component POST Request Handler. Executing a manipulation of the argument Time can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used.
CVE-2025-11586 Crítica · 9.8 CWE-119 10/10/2025
Tenda AC7 setNotUpgrade stack-based overflow
A vulnerability was determined in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/setNotUpgrade. This manipulation of the argument newVersion causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.
CVE-2025-11528 Alta · 8.8 CWE-119 09/10/2025
Tenda AC7 saveAutoQos stack-based overflow
A vulnerability was identified in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/saveAutoQos. The manipulation of the argument enable leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
CVE-2025-11527 Alta · 8.8 CWE-119 09/10/2025
Tenda AC7 fast_setting_pppoe_set stack-based overflow
A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing a manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.
CVE-2025-11526 Alta · 8.8 CWE-119 09/10/2025
Tenda AC7 WifiMacFilterSet stack-based overflow
A vulnerability was found in Tenda AC7 15.03.06.44. The affected element is an unknown function of the file /goform/WifiMacFilterSet. Performing a manipulation of the argument wifi_chkHz results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used.
CVE-2025-11525 Alta · 8.8 CWE-119 08/10/2025
Tenda AC7 SetUpnpCfg stack-based overflow
A vulnerability has been found in Tenda AC7 15.03.06.44. Impacted is an unknown function of the file /goform/SetUpnpCfg. Such manipulation of the argument upnpEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-11524 Alta · 8.8 CWE-119 08/10/2025
Tenda AC7 SetDDNSCfg stack-based overflow
A flaw has been found in Tenda AC7 15.03.06.44. This issue affects some unknown processing of the file /goform/SetDDNSCfg. This manipulation of the argument ddnsEn causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been published and may be used.
CVE-2025-11523 Alta · 8.8 CWE-77 08/10/2025
Tenda AC7 AdvSetLanip command injection
A vulnerability was detected in Tenda AC7 15.03.06.44. This vulnerability affects unknown code of the file /goform/AdvSetLanip. The manipulation of the argument lanIp results in command injection. It is possible to launch the attack remotely. The exploit is now public and may be used.