Vulnerabilidades de CareCam
CVEs publicadas que afetam produtos de CareCam: 8 registro(s), com severidade, exploração e correções.
CVE-2026-85497
Crítica · 9.8
CWE-916 18/09/2026
CareCam CM2507 Use of Password Hash With Insufficient Computational Effort
CareCam CM2507 IP cameras store the device's root-account password using a fixed legacy password hash that provides insufficient resistance to offline cracking. An attacker who obtains the firmware image or password database could recover the associated credential, which may also be reusable across other devices running the same firmware.
CVE-2026-85478
Baixa · 3.5
CWE-306 18/09/2026
CareCam CM2507 Missing Authentication for Critical Function
A CM2507 IP camera running firmware version HMT.CM2507 v251211.1507 exposes an interactive bootloader through a physical debug interface without requiring authentication. An attacker with physical access could interrupt the normal boot process and access functionality that permits inspection or modification of boot configuration, firmware data, and software loaded by the device.
CVE-2026-81321
Crítica · 9.8
CWE-312 18/09/2026
CareCam CM2507 Cleartext Storage of Sensitive Information
CM2507 IP cameras store configured wireless network credentials in cleartext within the device filesystem. An attacker who obtains filesystem access through physical access, a debugging interface, or another vulnerability could recover the configured network identifier and pre-shared key.
CVE-2026-88259
Alta · 7.5
CWE-306 18/09/2026
CareCam CM2507 Missing Authentication for Critical Function
CareCam CM2507 IP cameras do not require authentication for access to its network video streaming service. An unauthenticated attacker with network access to the affected device could retrieve live camera video.
CVE-2026-84400
Baixa · 3.1
CWE-306 18/09/2026
CareCam CM2507 Missing Authentication for Critical Function
CareCam CM2507 IP cameras contain an insufficiently protected network maintenance mechanism that can activate a remote debugging service. An attacker on the same local network who satisfies certain device state conditions could make the service remotely accessible, increasing the risk of unauthorized administrative access.
CVE-2026-84398
Alta · 7.5
CWE-258 18/09/2026
CareCam CM2507 Empty Password in Configuration File
CM2507 IP cameras accept an empty password for a privileged account exposed through its ONVIF management service. An attacker with network access to the affected device could access privileged management functions and obtain device, user, media-profile, and stream configuration information.
CVE-2026-81305
Média · 6.8
CWE-829 18/09/2026
CareCam CM2507 Inclusion of Functionality from Untrusted Control Sphere
CM2507 IP cameras automatically execute a predetermined script from removable media without verifying its authenticity or integrity. An attacker with physical access to the device could supply a malicious script and execute arbitrary code in the security context of the affected device.
CVE-2026-85083
Média · 6.8
CWE-798 11/09/2026
CareCam Pro IP Cameras Use of Hard-coded Credentials
The ANJIA AJL33PC0801 IP camera uses a hard-coded credential for bootloader authentication. An attacker with physical access to the device may leverage this weakness to gain privileged bootloader access, allowing unauthorized modification of firmware and system configuration and potentially resulting in complete device compromise.