Vulnerabilidades de Edimax
CVEs publicadas que afetam produtos de Edimax: 113 registro(s), com severidade, exploração e correções.
EW-7438RPn 24BR-6208AC 16EW-7478APC 14BR-6675nD 12BR-6478AC 11BR-6428NS 7Br-6208ac Firmware 6Gs-5008pl Firmware 5Ew-7438rpn Mini Firmware 5BR-6478AC V2 5BR-6428nC 4Br-6478ac V3 Firmware 3BR-6478AC V3 3BR-6214K 2Br-6288acl Firmware 1BR-6288ACL 1Br-6258n Firmware 1BR-6228NC 1BR-6258n 1IC-7100 IP Camera 1Ic-7100 Firmware 1
CVE-2026-9346
Alta · 8.8
CWE-119 23/05/2026
Edimax EW-7438RPn webs formWirelessTbl buffer overflow
A flaw has been found in Edimax EW-7438RPn up to 1.31. This impacts the function formWirelessTbl of the file /goform/formWirelessTbl of the component webs. Executing a manipulation of the argument submit-url can lead to buffer overflow. The attack may be performed from remote. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-9345
Alta · 8.8
CWE-119 23/05/2026
Edimax EW-7438RPn webs formWizSurvey buffer overflow
A vulnerability was detected in Edimax EW-7438RPn up to 1.31. This affects the function formWizSurvey of the file /goform/formWizSurvey of the component webs. Performing a manipulation of the argument ssid/manualssid/ip/mask/gateway results in buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-9344
Alta · 8.8
CWE-119 23/05/2026
Edimax EW-7438RPn webs formWpsStart stack-based overflow
A security vulnerability has been detected in Edimax EW-7438RPn up to 1.31. The impacted element is an unknown function of the file /goform/formWpsStart of the component webs. Such manipulation of the argument pinCode/wlan-url leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-9343
Média · 6.3
CWE-77 23/05/2026
Edimax EW-7438RPn webs formWpsStart os command injection
A weakness has been identified in Edimax EW-7438RPn up to 1.31. The affected element is the function formWpsStart of the file /goform/formWpsStart of the component webs. This manipulation of the argument pinCode causes os command injection. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-9297
Média · 6.3
CWE-74 23/05/2026
Edimax BR-6428NS POST Request formWlbasic command injection
A security vulnerability has been detected in Edimax BR-6428NS 1.10. Affected is the function formWlbasic of the file /goform/formWlbasic of the component POST Request Handler. The manipulation of the argument repeaterSSID leads to command injection. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-9296
Média · 6.3
CWE-74 23/05/2026
Edimax BR-6428NS POST Request formWlanM system command injection
A weakness has been identified in Edimax BR-6428NS 1.10. This impacts the function system of the file /goform/formWlanM of the component POST Request Handler. Executing a manipulation of the argument ateFunc/ateGain/ateTxCount/ateChan/ateRate/ateMacID/e2pTxPower1/e2pTxPower2/e2pTxPower3/e2pTxPower4/e2pTxPower5/e2pTxPower6/e2pTxPower7/e2pTx2Power1/e2pTx2Power2/e2pTx2Power3/e2pTx2Power4/e2pTx2Power5/e2pTx2Power6/e2pTx2Power7/ateTxFreqOffset/ateMode/ateBW/ateAntenna/e2pTxFreqOffset/e2pTxPwDeltaB/e2pTxPwDeltaG/e2pTxPwDeltaMix/e2pTxPwDeltaN/readE2P can lead to command injection. The attack can be launched remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-9295
Alta · 8.8
CWE-119 23/05/2026
Edimax BR-6428NS POST Request formWirelessTbl buffer overflow
A security flaw has been discovered in Edimax BR-6428NS 1.10. This affects the function formWirelessTbl of the file /goform/formWirelessTbl of the component POST Request Handler. Performing a manipulation of the argument vapurl results in buffer overflow. The attack can be initiated remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-9294
Alta · 8.8
CWE-119 23/05/2026
Edimax BR-6428NS POST Request formWanTcpipSetup buffer overflow
A vulnerability was identified in Edimax BR-6428NS 1.10. The impacted element is the function formWanTcpipSetup of the file /goform/formWanTcpipSetup of the component POST Request Handler. Such manipulation of the argument pppUserName leads to buffer overflow. It is possible to launch the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-8777
Média · 6.3
CWE-74 17/05/2026
Edimax BR-6428NS POST Request formStaDrvSetup command injection
A vulnerability was found in Edimax BR-6428NS 1.10. This issue affects the function formStaDrvSetup of the file /goform/formStaDrvSetup of the component POST Request Handler. Performing a manipulation of the argument stadrv_ssid results in command injection. The attack can be initiated remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-8776
Alta · 8.8
CWE-119 17/05/2026
Edimax BR-6428NS POST Request formPPTPSetup buffer overflow
A vulnerability has been found in Edimax BR-6428NS 1.10. This vulnerability affects the function formPPTPSetup of the file /goform/formPPTPSetup of the component POST Request Handler. Such manipulation of the argument pptpUserName leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-8775
Alta · 8.8
CWE-119 17/05/2026
Edimax BR-6428NS POST Request formL2TPSetup buffer overflow
A flaw has been found in Edimax BR-6428NS 1.10. This affects the function formL2TPSetup of the file /goform/formL2TPSetup of the component POST Request Handler. This manipulation of the argument L2TPUserName causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-8774
Média · 6.3
CWE-74 17/05/2026
Edimax BR-6228NC POST Request mp command injection
A vulnerability was detected in Edimax BR-6228NC 1.22. Affected by this issue is the function mp of the file /goform/mp of the component POST Request Handler. The manipulation of the argument command results in command injection. The attack may be performed from remote. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-7685
Alta · 8.8
CWE-119 03/05/2026
Edimax BR-6208AC setWAN buffer overflow
A vulnerability was detected in Edimax BR-6208AC up to 1.02. Affected is an unknown function of the file /goform/setWAN. Performing a manipulation of the argument pptpDfGateway results in buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-7684
Alta · 8.8
CWE-119 03/05/2026
Edimax BR-6428nC setWAN buffer overflow
A security vulnerability has been detected in Edimax BR-6428nC up to 1.16. This impacts an unknown function of the file /goform/setWAN. Such manipulation of the argument pptpDfGateway leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-7683
Média · 6.3
CWE-74 03/05/2026
Edimax BR-6428nC Web setWAN command injection
A weakness has been identified in Edimax BR-6428nC up to 1.16. This affects an unknown function of the file /goform/setWAN of the component Web Interface. This manipulation of the argument pppUserName/pptpUserName causes command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-7682
Média · 6.3
CWE-74 03/05/2026
Edimax BR-6208AC L2TP Mode setWAN command injection
A security flaw has been discovered in Edimax BR-6208AC 1.02. The impacted element is the function setWAN of the file /goform/setWAN of the component L2TP Mode. The manipulation of the argument L2TPUserName results in command injection. It is possible to launch the attack remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-32842
Média · 6.5
CWE-312 17/03/2026
Edimax GS-5008PL <= 1.00.54 Admin Credentials Stored in Cleartext
Edimax GS-5008PL firmware version 1.00.54 and prior contain an insecure credential storage vulnerability that allows attackers to obtain administrator credentials by accessing configuration backup files. Attackers can download the config.bin file through fupload.cgi to extract plaintext username and password fields for unauthorized administrative access.
CVE-2026-32841
Alta · 8.1
CWE-1108 17/03/2026
Edimax GS-5008PL <= 1.00.54 Global Authentication State Across All Clients
Edimax GS-5008PL firmware versions 1.00.54 and prior contain an authentication bypass vulnerability that allows unauthenticated attackers to access the management interface. Attackers can exploit the global authentication flag mechanism to gain administrative access without credentials after any user authenticates, enabling unauthorized password changes, firmware uploads, and configuration modifications.
CVE-2026-32840
Média · 5.4
CWE-79 17/03/2026
Edimax GS-5008PL <= 1.00.54 Stored XSS via Device Name
Edimax GS-5008PL firmware version 1.00.54 and prior contain a stored cross-site scripting vulnerability in the system_name_set.cgi script that allows attackers to inject arbitrary script code by manipulating the sysName parameter. Attackers can send a crafted POST request with malicious script payload that executes when management pages including system_data.js are viewed by administrators.
CVE-2026-32839
Média · 6.5
CWE-352 17/03/2026
Edimax GS-5008PL <= 1.00.54 CSRF via Management CGI Endpoints
Edimax GS-5008PL firmware version 1.00.54 and prior contain a cross-site request forgery vulnerability that allows remote attackers to perform unauthorized administrative actions by inducing logged-in administrators to visit malicious pages. Attackers can exploit the lack of anti-CSRF tokens and request validation to change passwords, upload firmware, reboot the device, perform factory resets, or modify network configurations.
CVE-2026-32838
Média · 5.9
CWE-319 17/03/2026
Edimax GS-5008PL <= 1.00.54 Transmits Credentials Over Cleartext HTTP
Edimax GS-5008PL firmware version 1.00.54 and prior use cleartext HTTP for the web management interface without implementing TLS or SSL encryption. Attackers on the same network can intercept management traffic to capture administrator credentials and sensitive configuration data.
CVE-2026-1972
Alta · 7.5
CWE-1392 05/02/2026
Edimax BR-6208AC auth_check_userpass2 default credentials
A vulnerability was found in Edimax BR-6208AC 2_1.02. The affected element is the function auth_check_userpass2. Performing a manipulation of the argument Username/Password results in use of default credentials. The attack may be initiated remotely. The exploit has been made public and could be used. The vendor confirms that the affected product is end-of-life. They confirm that they "will issue a consolidated Security Advisory on our official support website." This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2026-1971
Média · 4.8
CWE-79 05/02/2026
Edimax BR-6288ACL wiz_WISP24gmanual.asp wiz_WISP24gmanual cross site scripting
A vulnerability has been found in Edimax BR-6288ACL up to 1.12. Impacted is the function wiz_WISP24gmanual of the file wiz_WISP24gmanual.asp. Such manipulation of the argument manualssid leads to cross site scripting. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor confirms that the affected product is end-of-life. They confirm that they "will issue a consolidated Security Advisory on our official support website." This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2026-1970
Média · 6.1
CWE-601 05/02/2026
Edimax BR-6258n formStaDrvSetup redirect
A flaw has been found in Edimax BR-6258n up to 1.18. This issue affects the function formStaDrvSetup of the file /goform/formStaDrvSetup. This manipulation of the argument submit-url causes open redirect. The attack can be initiated remotely. The exploit has been published and may be used. The vendor confirms that the affected product is end-of-life. They confirm that they "will issue a consolidated Security Advisory on our official support website." This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2020-37150
Alta · 7.5
CWE-201 05/02/2026
Edimax Technology EW-7438RPn-v3 Mini 1.27 - Unauthorized Access: Wi-Fi Password Disclosure
Edimax EW-7438RPn-v3 Mini 1.27 allows unauthenticated attackers to access the /wizard_reboot.asp page in unsetup mode, which discloses the Wi-Fi SSID and security key. Attackers can retrieve the wireless password by sending a GET request to this endpoint, exposing sensitive information without authentication.