CVEs publicadas que afetam produtos de Schneider Electric: 47 registro(s), com severidade, exploração e correções.

Somente exploradas (KEV) →

CVE-2026-2404 Média · 5.3 CWE-116 14/04/2026
Improper Encoding or Escaping of Output em Schneider Electric Powerchute Serial Shutdown
CWE-116 Improper Encoding or Escaping of Output vulnerability exists that could cause log injection and forged log when an attacker alters the POST /j_security check request payload.
CVE-2026-2403 Média · 4.3 CWE-1284 14/04/2026
CWE-1284 Improper Validation of Specified Quantity in Input vulnerability exists that…
CWE-1284 Improper Validation of Specified Quantity in Input vulnerability exists that could cause Event and Data Log truncation impacting log integrity when a Web Admin user alters the POST /logsettings request payload.
CVE-2026-2402 Média · 5.3 CWE-307 14/04/2026
Improper Restriction of Excessive Authentication Attempts em Schneider Electric Powerchute Serial Shutdown
CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on a sequence of requests to multiple endpoints.
CVE-2026-2401 Média · 5.0 CWE-532 14/04/2026
Insertion of Sensitive Information into Log File em Schneider Electric Powerchute Serial Shutdown
CWE-532 Insertion of Sensitive Information into Log File vulnerability exists that could cause confidential information to be exposed when a Web Admin user executes a malicious file provided by an attacker.
CVE-2026-2400 Média · 4.3 CWE-93 14/04/2026
CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection') vulnerability exists…
CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection') vulnerability exists that could cause application user credentials to reset when a Web Admin user alters the POST /setPCBEDesc request payload.
CVE-2026-2399 Média · 6.1 CWE-22 14/04/2026
Path Traversal em Schneider Electric Powerchute Serial Shutdown
CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause critical files overwritten with text data when a Web Admin user alters the POST /REST/upssleep request payload.
CVE-2026-2273 Alta · 8.2 CWE-94 10/03/2026
Code Injection em Schneider Electric Ecostruxure Automation Expert
CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the workstation and a potential loss of Confidentiality, Integrity and Availability of the subsequent system when an authenticated user opens a malicious project file.
CVE-2026-1286 Média · 6.5 CWE-502 10/03/2026
Deserialization of Untrusted Data em Schneider Electric Ecostruxure Foxboro Dcs Control Software
CWE-502: Deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on workstation when an admin authenticated user opens a malicious project file.
CVE-2025-13957 Alta · 7.5 CWE-798 10/03/2026
Use of Hard-coded Credentials em Schneider Electric EcoStruxure™ IT Data Center Expert (Formerly known as StruxureWare Data Center Expert)
CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator credentials and PostgreSQL database credentials are known. SOCKS Proxy is disabled by default.
CVE-2025-13902 Média · 5.4 CWE-79 10/03/2026
Cross-site Scripting (XSS) em Schneider Electric Modicon M258 Firmware
CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload.
CVE-2025-13901 Média · 5.3 CWE-404 10/03/2026
Improper Resource Shutdown or Release em Schneider Electric Modicon M241 Firmware
CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels.
CVE-2025-11739 Alta · 7.8 CWE-502 10/03/2026
Deserialization of Untrusted Data em Schneider Electric Ecostruxure Power Monitoring Expert
CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization.
CVE-2026-1227 Alta · 7.0 CWE-611 11/02/2026
XML External Entity (XXE) em Schneider Electric EcoStruxure Building Operation Workstation
CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized disclosure of local files, interaction within the EBO system, or denial of service conditions when a local user uploads a specially crafted TGML graphics file to the EBO server from Workstation.
CVE-2026-1226 Alta · 7.0 CWE-94 11/02/2026
Code Injection em Schneider Electric EcoStruxure Building Operation Workstation
CWE‑94: Improper Control of Generation of Code vulnerability exists that could cause execution of untrusted or unintended code within the application when maliciously crafted design content is processed through a TGML graphics file.
CVE-2025-13905 Alta · 7.0 CWE-276 29/01/2026
Incorrect Default Permissions em Schneider Electric EcoStruxure™ Process Expert
CWE-276: Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse shell when one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart.
CVE-2025-13845 Alta · 7.8 CWE-416 15/01/2026
Use After Free em Schneider Electric Ecostruxure Power Build - Rapsody
CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody.
CVE-2025-13844 Média · 5.3 CWE-415 15/01/2026
Double Free em Schneider Electric Ecostruxure Power Build - Rapsody
CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker into Rapsody.
CVE-2025-11567 Alta · 7.3 CWE-276 12/11/2025
Incorrect Default Permissions em Schneider Electric Powerchute Serial Shutdown
CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured.
CVE-2025-11566 Média · 6.9 CWE-307 12/11/2025
Improper Restriction of Excessive Authentication Attempts em Schneider Electric Powerchute Serial Shutdown
CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on the local network to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on the /REST/shutdownnow endpoint.
CVE-2025-11565 Alta · 7.3 CWE-22 12/11/2025
Path Traversal em Schneider Electric Powerchute Serial Shutdown
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause elevated system access when a Web Admin user on the local network tampers with the POST /REST/UpdateJRE request payload.
CVE-2018-7841 Crítica · 9.8 KEV Urgente · 75 Exploit público CWE-89 22/05/2019
Schneider Electric U.motion Builder SQL Injection Vulnerability
A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an improper set of characters is entered.
CVE-2018-2811 Alta · 7.7 18/04/2018
Vulnerability in the Java SE component of Oracle Java SE (subcomponent: Install). Supported...
Vulnerability in the Java SE component of Oracle Java SE (subcomponent: Install). Supported versions that are affected are Java SE: 8u162 and 10. Difficult to exploit vulnerability allows unauthenticated attacker with logon to the infrastructure where Java SE executes to compromise Java SE. Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Java SE, attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Java SE. Note: Applies to installation process on client deployment of Java. CVSS 3.0 Base Score 7.7 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H).