Vulnerabilidades de Shenzhen Tenda Technology Co., Ltd.
CVEs publicadas que afetam produtos de Shenzhen Tenda Technology Co., Ltd.: 21 registro(s), com severidade, exploração e correções.
CVE-2026-27514
Média · 6.5
CWE-201 23/02/2026
Tenda F3 Plaintext Credential Exposure in Configuration Download
Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a sensitive information exposure vulnerability in the configuration download functionality. The configuration download response includes the router password and administrative password in plaintext. The endpoint also omits appropriate Cache-Control directives, which can allow the response to be stored in client-side caches and recovered by other local users or processes with access to cached browser data.
CVE-2026-27513
Média · 4.3
CWE-352 23/02/2026
Tenda F3 CSRF in Web Management Interface
Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a cross-site request forgery (CSRF) vulnerability in the web-based administrative interface. The interface does not implement anti-CSRF protections, allowing an attacker to induce an authenticated administrator to submit state-changing requests, which can result in unauthorized configuration changes.
CVE-2026-27512
Média · 6.1
CWE-79 23/02/2026
Tenda F3 Reflected Script Execution via Missing nosniff Header
Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a content-type confusion vulnerability in the administrative interface. Responses omit the X-Content-Type-Options: nosniff header and include attacker-influenced content that can be reflected into the response body. Under affected browser behaviors, MIME sniffing may cause the response to be interpreted as active HTML, enabling script execution in the context of the administrative interface.
CVE-2026-27511
Média · 4.3
CWE-1021 23/02/2026
Tenda F3 Clickjacking in Web Management Interface
Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a clickjacking vulnerability in the web-based administrative interface. The interface does not set the X-Frame-Options header, allowing attacker-controlled sites to embed administrative pages in an iframe and trick an authenticated administrator into unintended interactions that may result in unauthorized configuration changes.
CVE-2026-25857
Alta · 8.8
CWE-78 07/02/2026
Tenda G300-F Command Injection via formSetWanDiag
Tenda G300-F router firmware version 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality (formSetWanDiag). The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without adequate neutralization. As a result, a remote attacker with access to the affected management interface can inject additional shell syntax and execute arbitrary commands on the device with the privileges of the management process.
CVE-2026-24441
Média · 5.9
CWE-319 03/02/2026
Tenda AC7 Transmits Admin Credentials Without HTTPS Protection
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose account credentials in plaintext within HTTP responses, allowing an on-path attacker to obtain sensitive authentication material.
CVE-2026-24434
Média · 6.5
CWE-352 03/02/2026
Tenda AC7 Web Interface Lacks CSRF Protections for Admin Actions
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior does not implement CSRF protections for administrative functions in the web management interface. The interface does not enforce anti-CSRF tokens or robust origin validation, which can allow an attacker to induce a logged-in administrator to perform unintended state-changing requests and modify router settings.
CVE-2026-24427
Média · 5.5
CWE-201 03/02/2026
Tenda AC7 Exposes Admin Credentials in Configuration Responses
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose sensitive information in web management responses. Administrative credentials, including the router and/or admin panel password, are included in plaintext within configuration response bodies. In addition, responses lack appropriate Cache-Control directives, which may permit web browsers to cache pages containing these credentials and enable subsequent disclosure to an attacker with access to the client system or browser profile.
CVE-2026-24426
Média · 6.1
CWE-79 03/02/2026
Tenda AC7 Reflected XSS via Web Interface Output Encoding
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior contain an improper output encoding vulnerability in the web management interface. User-supplied input is reflected in HTTP responses without adequate escaping, allowing injection of arbitrary HTML or JavaScript in a victim’s browser context.
CVE-2026-24440
Alta · 8.8
CWE-620 26/01/2026
Tenda W30E V2 Allows Password Changes Without Verifying Current Password
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) allow account passwords to be changed through the maintenance interface without requiring verification of the existing password. This enables unauthorized password changes when access to the affected endpoint is obtained.
CVE-2026-24439
Média · 6.5
CWE-116 26/01/2026
Tenda W30E V2 Lacks X-Content-Type-Options Header
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) fail to include the X-Content-Type-Options: nosniff response header on web management interfaces. As a result, browsers that perform MIME sniffing may incorrectly interpret attacker-influenced responses as executable script.
CVE-2026-24437
Média · 5.5
CWE-525 26/01/2026
Tenda W30E V2 Missing Cache Controls for Credential-bearing Pages
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) serve sensitive administrative content without appropriate cache-control directives. As a result, browsers may store credential-bearing responses locally, exposing them to subsequent unauthorized access.
CVE-2026-24436
Crítica · 9.8
CWE-307 26/01/2026
Tenda W30E V2 Lacks Rate Limiting on Authentication
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) do not enforce rate limiting or account lockout mechanisms on authentication endpoints. This allows attackers to perform unrestricted brute-force attempts against administrative credentials.
CVE-2026-24435
Média · 6.5
CWE-942 26/01/2026
Tenda W30E V2 Permissive CORS Allows Cross-origin Data Access
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) implement an insecure Cross-Origin Resource Sharing (CORS) policy on authenticated administrative endpoints. The device sets Access-Control-Allow-Origin: * in combination with Access-Control-Allow-Credentials: true, allowing attacker-controlled origins to issue credentialed cross-origin requests.
CVE-2026-24433
Média · 5.4
CWE-79 26/01/2026
Tenda W30E V2 Stored XSS via Username Field
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) contain a stored cross-site scripting vulnerability in the user creation functionality. Insufficient input validation allows attacker-controlled script content to be stored and later executed when administrative users access the affected management pages.
CVE-2026-24432
Média · 4.3
CWE-352 26/01/2026
Tenda W30E V2 Missing CSRF Protections for Administrative Actions
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) lack cross-site request forgery (CSRF) protections on administrative endpoints, including those used to change administrator account credentials. As a result, an attacker can craft malicious requests that, when triggered by an authenticated user’s browser, modify administrative passwords and other configuration settings.
CVE-2026-24431
Média · 6.5
CWE-317 26/01/2026
Tenda W30E V2 Web UI Reveals Passwords in Cleartext
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) display stored user account passwords in plaintext within the administrative web interface. Any user with access to the affected management pages can directly view credentials.
CVE-2026-24430
Alta · 7.5
CWE-201 26/01/2026
Tenda W30E V2 HTTP Responses Expose Plaintext Credentials
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) disclose sensitive account credentials in cleartext within HTTP responses generated by the maintenance interface. Because the management interface is accessible over unencrypted HTTP by default, credentials may be exposed to network-based interception.
CVE-2026-24429
Crítica · 9.8
CWE-1393 26/01/2026
Tenda W30E V2 Hardcoded Default Password for Built-in Account
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) ship with a predefined default password for a built-in authentication account that is not required to be changed during initial configuration. An attacker can leverage these default credentials to gain authenticated access to the management interface.
CVE-2026-24428
Alta · 8.8
CWE-863 26/01/2026
Tenda W30E V2 Incorrect Authorization Allows Administrator Password Change
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) contain an authorization flaw in the user management API that allows a low-privileged authenticated user to change the administrator account password. By sending a crafted request directly to the backend endpoint, an attacker can bypass role-based restrictions enforced by the web interface and obtain full administrative privileges.
CVE-2021-47802
Alta · 7.5
CWE-306 21/01/2026
Tenda D151 & D301 - Configuration Download
Tenda D151 and D301 routers contain an unauthenticated configuration download vulnerability that allows remote attackers to retrieve router configuration files. Attackers can send a request to /goform/getimage endpoint to download configuration data including admin credentials without authentication.