CVE-2025-14097 — Remote Code Execution Vulnerability in Radiometer Products

A vulnerability in the application software of multiple Radiometer products may allow remote code execution and unauthorized device management when specific internal conditions are met. Exploitation requires that a remote connection is established with additional information obtained through other means. The issue is caused by a weakness in the analyzer’s application software.                                                                                                                                                                                                Other related CVE's are CVE-2025-14095 & CVE-2025-14096.                                                                                                      Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency. Required Configuration for Exposure: Affected application software version is in use and remote support feature is enabled in the analyzer.                                                                                                                                                                        Temporary work Around: If the network is not considered secure, please remove the analyzer from the network.                         Permanent solution: Customers should ensure the following: • The network is secure, and access follows best practices. Local Radiometer representatives will contact all affected customers to discuss a permanent solution.                                                      Exploit Status: Researchers have provided working proof-of-concept (PoC). Radiometer is not aware of any publicly available exploits at the time of this publication.

Descrição oficial em inglês (tradução ainda não revisada).

Publicada em 17/12/2025 · Atualizada em 13/10/2026 · Fontes: NIST National Vulnerability Database, CVE Program (cve.org) e CISA ADP · CNA: Radiometer

Quem explora e qual a prioridade

Nota de 0 a 100 que combina exploração confirmada, uso por ransomware e grupos APT, exploits públicos, EPSS e severidade.

Nenhum sinal de exploração nas fontes consultadas até agora.
Como a nota foi calculada
  • EPSS 0.5% (probabilidade de exploração em 30 dias)+6
  • Severidade técnica (high)+6

A nota ordena a fila de correção; não substitui o contexto dos seus ativos (exposição à internet, criticidade, compensações).

Triagem

Está sendo explorada, qual a probabilidade de exploração, o que afeta e qual a severidade segundo as fontes.

Exploração
Não confirmada
Fora da CISA KEV — ausência de registro, não prova de que não é explorada.
EPSS FIRST
0,47%
à frente de 39% das CVEs pontuadas · 14/10/2026
Afeta
Radiometer Medical Aps
ABL800 BASIC and ABL800 FLEX analyzers e mais 2
CVSS base
7.2
Alta · 2 fonte(s)

Avaliação SSVC da CISA CISA

Três pontos de decisão que a CISA publica para as CVEs que avalia (SSVC 2.0.3). Uma decisão de priorização, não uma nota de severidade.

Exploração
Nenhuma
nenhuma · prova de conceito · ativa
Automatizável
Não
se um atacante consegue automatizar as etapas da cadeia de ataque
Impacto técnico
Total
parcial · controle total do componente vulnerável

Remediação

Correções e mitigações documentadas pelas fontes — com link para o aviso original.

Nenhuma correção documentada pelas fontes consultadas. Isso não significa que não exista: verifique o aviso do fabricante.

Primeiras 24 horas

Ordenado a partir dos próprios campos do registro — exposição primeiro, porque não se corrige o que não se encontrou. Ponto de partida, gerado por regras.

  1. Identifique ativos expostos que executam as combinações de fabricante/produto/versão afetadas (Radiometer Medical Aps ABL800 BASIC and ABL800 FLEX analyzers, Radiometer Medical Aps ABL90 FLEX and ABL90 FLEX PLUS Analyzers, Radiometer Medical Aps AQT90 FLEX Analyzers).
  2. Nenhuma correção documentada nas fontes: reduza a exposição e monitore o aviso do fabricante.
  3. Procure nos logs disponíveis sinais de tentativa de exploração compatíveis com a classe da falha (autenticação), erros e anomalias de autenticação.

Escopo afetado

Fabricante, produto e versões como as fontes os descrevem.

FabricanteProdutoVersõesStatusFonte
Radiometer Medical Aps ABL800 BASIC and ABL800 FLEX analyzers versão Application software versions < 6.20MR2 with Windows 7, Windows XP operating sys Vulnerável CVE Program (cve.org) e CISA ADP
Radiometer Medical Aps ABL90 FLEX and ABL90 FLEX PLUS Analyzers versão Application software versions < 3.5MR11 with Windows 7, Windows XP operating sys Vulnerável CVE Program (cve.org) e CISA ADP
Radiometer Medical Aps AQT90 FLEX Analyzers versão Application software versions <= 8.13 MR2 with Windows 7, Windows XP operating s Vulnerável CVE Program (cve.org) e CISA ADP

Características do ataque

O vetor CVSS decodificado. Descreve o ataque, não a sua exposição a ele.

Vetor de ataque
Rede
Complexidade
Baixa
Privilégios exigidos
Altos
Interação do usuário
Nenhuma
Escopo
Inalterado
Confidencialidade
Alto
Integridade
Alto
Disponibilidade
Alto

Todas as pontuações coletadas

As fontes pontuam de forma independente e podem discordar; cada linha diz quem pontuou e em qual versão.

NotaVersãoSeveridadeExplor.ImpactoPontuado por
7.2 CVSS 3.1 Alta 1.2 5.9 46b595e9-1acc-41cb-9398-adaf98d37a9b via NIST National Vulnerability Database
7.2 CVSS 3.1 Alta — — Radiometer via CVE Program (cve.org) e CISA ADP
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H (nota exibida no topo: 46b595e9-1acc-41cb-9398-adaf98d37a9b)

Fraqueza MITRE

Classe de fraqueza segundo o catálogo CWE do MITRE.

CWE-287 · Improper Authentication

Outras CVEs com esta fraqueza →

EPSS ao longo do tempo FIRST

13/10/2026 → 14/10/2026 · 2 leitura(s) · máximo 0.47%

Detecção

Derivado do vetor CVSS e da classe da fraqueza. Pontos de partida, não regras testadas.

  • Priorize telemetria de borda para o componente exposto na rede (proxy, WAF, IDS/IPS).
  • Revise logs de autenticação: logins sem MFA, sessões anômalas e contas criadas recentemente.
logs web/proxy/WAFIDS/IPS de redelogs de autenticação

Linha do tempo

O que aconteceu com esta CVE, do mais recente ao mais antigo.

  • 2026
  • Produtos afetados adicionados · radiometer medical aps/abl90 flex and abl90 flex plus analyzers, radiometer medical aps/abl800 basic and abl800 flex ana
    13/10/2026 · CVE Program (cve.org) e CISA ADP
  • Avaliação SSVC atualizada
    13/10/2026 · CVE Program (cve.org) e CISA ADP
  • Ficha publicada
    13/10/2026
  • CVSS alterado · 7.2
    13/10/2026 · NIST National Vulnerability Database
  • Status na fonte alterado · → Deferred
    13/10/2026 · NIST National Vulnerability Database
  • Registro criado nesta base
    13/10/2026 · NIST National Vulnerability Database
  • 2025
  • CVE publicada
    17/12/2025 · Radiometer

Atividade das fontes

Leituras que se repetem foram contadas em vez de listadas.

  • 1× Descrição oficial atualizada · 13/10/2026 – 13/10/2026

Referências

1 no registro

Em outras páginas do site

Radiometer Medical Aps
todas as CVEs deste fabricante
Autenticação
mesma classe
CWE-287
outras páginas com esta fraqueza

CVEs relacionadas (mesmos produtos)

  • Alta CVE-2025-14096 Credential Disclosure vulnerability in Radiometer Products 17/12/2025
  • Média CVE-2025-14095 Privilege boundary violation in Radiometer Products 17/12/2025

Não consta em nenhuma fonte consultada

Listado em vez de deixado em branco: um campo vazio e um não medido parecem iguais na tela, e só um deles é motivo para procurar em outro lugar.

  • Nenhuma versão corrigida, patch ou mitigação documentada.
  • Nenhum IOC confirmado (IPs, domínios, hashes ou artefatos de malware) fornecido.
  • Nenhum inventário de ativos, controle compensatório ou evidência de implantação de patch da sua organização.
  • Nenhuma captura de tráfego de exploração, amostra de log ou caso de incidente.

Respondido a partir deste registro

Texto montado apenas com os campos acima — sem afirmações adicionais.

O que os defensores devem saber primeiro?

CVE-2025-14097 é "Remote Code Execution Vulnerability in Radiometer Products", de severidade Alta. Afeta ABL800 BASIC and ABL800 FLEX analyzers (Radiometer Medical Aps); as versões estão na tabela de escopo. Não está na CISA KEV, o que não exclui exploração. CVSS 7.2 descreve a severidade técnica. EPSS 0.47% estima a probabilidade de exploração em 30 dias; nenhum dos dois substitui o contexto dos seus ativos. Verifique primeiro se ativos expostos ou críticos executam as versões afetadas, aplique as correções ou mitigações do fabricante e preserve logs para análise.