CVE-2021-22681 — Rockwell Multiple Products Insufficient Protected Credentials Vulnerability
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.
Who exploits it and how urgent it is
A 0–100 score combining confirmed exploitation, ransomware and APT use, public exploits, EPSS and severity.
How the score was calculated
- Confirmed exploitation (CISA KEV)+35
- Public exploit/PoC (github)+6
- EPSS 63.6% (30-day exploitation probability)+15
- Technical severity (critical)+10
- Automatable exploitation (SSVC)+3
The score orders the patch queue; it does not replace your asset context (internet exposure, criticality, compensating controls).
Triage
Is it exploited, how likely is exploitation, what does it touch, and how severe do the sources call it.
CISA SSVC assessment CISA
Three decision points CISA publishes for the CVEs it assesses (SSVC 2.0.3). A stakeholder decision, not a severity score.
Remediation
Fixes and mitigations documented by the sources — linked to the original advisory.
No fix documented by the sources we poll. That does not mean none exists: check the vendor advisory.
CISA required action CISA
Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.
US federal deadline: Mar 26, 2026 — passed 203 day(s) ago
First 24 hours
Ordered from the record’s own fields — exposure first, because you cannot patch what you have not found. A rule-generated starting point.
- Identify exposed assets running the affected vendor/product/version combinations (Rockwell Automation Factorytalk Services Platform, Rockwell Automation Rslogix 5000, Rockwell Automation Studio 5000 Logix Designer).
- Treat as emergency remediation: the CVE is in CISA KEV (confirmed exploitation).
- The attack is network-based and needs no privileges: restrict exposure (ACLs, VPN, WAF) until patched.
- No fix documented in the sources: reduce exposure and monitor the vendor advisory.
- EPSS ahead of 99% of scored CVEs: prioritize it in the patch queue.
- Search available logs for exploit probes matching the vulnerability class (authentication), errors and authentication anomalies.
Affected scope
Vendor, product and versions as the sources word them.
| Vendor | Product | Versions | Status | Source |
|---|---|---|---|---|
| Rockwell Automation | Factorytalk Services Platform | ≥ 2.10 | Vulnerable | NIST National Vulnerability Database |
| Rockwell Automation | Rslogix 5000 | ≥ 16 and ≤ 20 | Vulnerable | NIST National Vulnerability Database |
| Rockwell Automation | Studio 5000 Logix Designer | ≥ 21.0 | Vulnerable | NIST National Vulnerability Database |
Attack characteristics
The CVSS vector, decoded. It describes the attack, not your exposure to it.
Every base score collected
Sources score independently and may disagree; each row says who scored it and under which version.
| Score | Version | Severity | Expl. | Impact | Scored by |
|---|---|---|---|---|---|
| 9.8 | CVSS 3.1 | Critical | 3.9 | 5.9 | nvd@nist.gov via NIST National Vulnerability Database |
| 9.8 | CVSS 3.1 | Critical | 3.9 | 5.9 | 134c704f-9b21-4f2e-91b3-4a467353bcc0 via NIST National Vulnerability Database |
| 9.8 | CVSS 3.1 | Critical | — | — | GitHub, Inc. via GitHub Security Advisories |
| 9.8 | CVSS 3.1 | Critical | — | — | CISA-ADP via CVE Program (cve.org) e CISA ADP |
| 7.5 | CVSS 2.0 | High | 10.0 | 6.4 | nvd@nist.gov via NIST National Vulnerability Database |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H (score shown at the top: nvd@nist.gov) Weakness MITRE
Weakness class according to MITRE’s CWE catalog.
CISA KEV details CISA
CISA lists a CVE once it has evidence of exploitation against real targets.
CISA records ransomware use only for campaigns it has confirmed, so “Unknown” means unrecorded, not ruled out. The deadline binds US federal agencies; for everyone else it is a reference date.
Public exploits, PoCs and detection templates
Public code that demonstrates or tests the flaw raises the odds of mass exploitation — and Nuclei templates help find vulnerable assets in your environment.
Warning: public PoCs are sometimes disguised malware. Use them only for authorized testing in an isolated environment. This portal does not host exploit code — it only points to the sources.
EPSS over time FIRST
Oct 12, 2026 → Oct 14, 2026 · 3 reading(s) · max 63.63%
Detection
Read off the CVSS vector and the weakness class. Starting points, not tested rules.
- Prioritize edge telemetry for the network-reachable component (proxy, WAF, IDS/IPS).
- Review authentication logs: logins without MFA, anomalous sessions and recently created accounts.
- Hunt retroactively in logs from before Mar 5, 2026 (KEV listing): exploitation may have started earlier.
Timeline
What happened to this CVE, newest first.
- 2026
- SSVC assessment updated
- Record published
- Affected products added · rockwellautomation/factorytalk services platform, rockwellautomation/rslogix 5000, rockwellautomation/studio 5000 logix
- CVSS changed · 9.8
- Source status changed · → Analyzed
- Added to CISA KEV (detected)
- Record created in this database
- Added to CISA KEV catalog
- 2021
- CVE published
Source activity
Repeated readings are counted rather than listed.
- 2× References added · Oct 13, 2026 – Oct 13, 2026
- 1× Official description updated · Oct 13, 2026 – Oct 13, 2026
References
4 on the record
Elsewhere on this site
Related CVEs (same products)
- High CVE-2026-9108 Studio 5000 Logix Designer® – Multiple Vulnerabilities Jul 14, 2026
- High CVE-2026-9127 Studio 5000 Logix Designer® – Multiple Vulnerabilities Jul 14, 2026
- High CVE-2026-9128 Studio 5000 Logix Designer® – Multiple Vulnerabilities Jul 14, 2026
- High CVE-2026-10714 Rockwell Automation FactoryTalk® Services Platform FTSP - Weak Authentication via JWT Validation Bypass Jul 14, 2026
Not in any source we poll
Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.
- No fixed version, patch or mitigation documented.
- No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
- No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
- No exploit packet captures, log samples, or incident case IDs supplied.
Answered from this record
Text assembled only from the fields above — no additional claims.
What should defenders know first?
CVE-2021-22681 is "Rockwell Multiple Products Insufficient Protected Credentials Vulnerability", rated Critical. It affects Factorytalk Services Platform (Rockwell Automation); versions are in the scope table. It is in CISA KEV: there is evidence of real-world exploitation. CVSS 9.8 describes technical severity. EPSS 63.63% estimates the probability of exploitation in 30 days; neither replaces your asset context. First verify whether exposed or business-critical assets run the affected versions, apply vendor fixes or mitigations, and preserve logs for review.
Comments
Moderated technical discussion. Read the community guidelines.
No comments yet.
Sign in or create an account to comment and suggest corrections.