CVE-2023-23080 — Certain Tenda products are vulnerable to command injection. This affects Tenda CP7 Tenda CP7<=V11...
Certain Tenda products are vulnerable to command injection. This affects Tenda CP7 Tenda CP7<=V11.10.00.2211041403 and Tenda CP3 v.10 Tenda CP3 v.10<=V20220906024_2025 and Tenda IT7-PCS Tenda IT7-PCS<=V2209020914 and Tenda IT7-LCS Tenda IT7-LCS<=V2209020914 and Tenda IT7-PRS Tenda IT7-PRS<=V2209020908.
Who exploits it and how urgent it is
A 0–100 score combining confirmed exploitation, ransomware and APT use, public exploits, EPSS and severity.
How the score was calculated
- EPSS 2.5% (30-day exploitation probability)+13
- Technical severity (critical)+10
- CISA SSVC: exploitation "poc"+5
- Automatable exploitation (SSVC)+3
The score orders the patch queue; it does not replace your asset context (internet exposure, criticality, compensating controls).
Triage
Is it exploited, how likely is exploitation, what does it touch, and how severe do the sources call it.
CISA SSVC assessment CISA
Three decision points CISA publishes for the CVEs it assesses (SSVC 2.0.3). A stakeholder decision, not a severity score.
Remediation
Fixes and mitigations documented by the sources — linked to the original advisory.
No fix documented by the sources we poll. That does not mean none exists: check the vendor advisory.
First 24 hours
Ordered from the record’s own fields — exposure first, because you cannot patch what you have not found. A rule-generated starting point.
- Identify exposed assets running the affected vendor/product/version combinations (Tenda Cp3 Firmware, Tenda Cp7 Firmware, Tenda It7-lcs Firmware…).
- The attack is network-based and needs no privileges: restrict exposure (ACLs, VPN, WAF) until patched.
- No fix documented in the sources: reduce exposure and monitor the vendor advisory.
- Search available logs for exploit probes matching the vulnerability class (injection), errors and authentication anomalies.
Affected scope
Vendor, product and versions as the sources word them.
| Vendor | Product | Versions | Status | Source |
|---|---|---|---|---|
| Tenda | Cp3 Firmware | ≤ 20220906024_2025 | Vulnerable | NIST National Vulnerability Database |
| Tenda | Cp7 Firmware | ≤ 1.10.00.2211041403 | Vulnerable | NIST National Vulnerability Database |
| Tenda | It7-lcs Firmware | ≤ 2209020914 | Vulnerable | NIST National Vulnerability Database |
| Tenda | It7-pcs Firmware | ≤ 2209020914 | Vulnerable | NIST National Vulnerability Database |
| Tenda | It7-prs Firmware | ≤ 2209020908 | Vulnerable | NIST National Vulnerability Database |
Attack characteristics
The CVSS vector, decoded. It describes the attack, not your exposure to it.
Every base score collected
Sources score independently and may disagree; each row says who scored it and under which version.
| Score | Version | Severity | Expl. | Impact | Scored by |
|---|---|---|---|---|---|
| 9.8 | CVSS 3.1 | Critical | 3.9 | 5.9 | nvd@nist.gov via NIST National Vulnerability Database |
| 9.8 | CVSS 3.1 | Critical | — | — | GitHub, Inc. via GitHub Security Advisories |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H (score shown at the top: nvd@nist.gov) Weakness MITRE
Weakness class according to MITRE’s CWE catalog.
EPSS over time FIRST
Oct 23, 2026 → Oct 24, 2026 · 2 reading(s) · max 2.46%
Detection
Read off the CVSS vector and the weakness class. Starting points, not tested rules.
- Prioritize edge telemetry for the network-reachable component (proxy, WAF, IDS/IPS).
- Look for parameters with command/query metacharacters and unexpected child processes of the service.
Timeline
What happened to this CVE, newest first.
- 2026
- SSVC assessment updated
- Record published
- Affected products added · tenda/it7-lcs firmware, tenda/it7-pcs firmware, tenda/it7-prs firmware, tenda/cp3 firmware, tenda/cp7 firmware
- CVSS changed · 9.8
- Source status changed · → Modified
- Record created in this database
- 2023
- CVE published
Source activity
Repeated readings are counted rather than listed.
- 2× References added · Oct 24, 2026 – Oct 24, 2026
- 1× Official description updated · Oct 24, 2026 – Oct 24, 2026
References
3 on the record
Elsewhere on this site
Not in any source we poll
Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.
- No fixed version, patch or mitigation documented.
- No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
- No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
- No exploit packet captures, log samples, or incident case IDs supplied.
Answered from this record
Text assembled only from the fields above — no additional claims.
What should defenders know first?
CVE-2023-23080 is "Certain Tenda products are vulnerable to command injection. This affects Tenda CP7 Tenda CP7<=V11...", rated Critical. It affects Cp3 Firmware (Tenda); versions are in the scope table. It is not in CISA KEV, which does not rule out exploitation. CVSS 9.8 describes technical severity. EPSS 2.46% estimates the probability of exploitation in 30 days; neither replaces your asset context. First verify whether exposed or business-critical assets run the affected versions, apply vendor fixes or mitigations, and preserve logs for review.
Comments
Moderated technical discussion. Read the community guidelines.
No comments yet.