CVE Intelligence
Critical Access control

CVE-2025-40805 — Authorization Bypass Through User-Controlled Key (IDOR) in Siemens Industrial Edge Cloud Device (IECD)

Affected devices do not properly enforce user authentication on specific API endpoints. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has learned the identity of a legitimate user.

Published Jan 13, 2026 · Updated Oct 13, 2026 · Sources: NIST National Vulnerability Database, CVE Program (cve.org) e CISA ADP · CNA: siemens

Who exploits it and how urgent it is

A 0–100 score combining confirmed exploitation, ransomware and APT use, public exploits, EPSS and severity.

No exploitation signal in the sources consulted so far.
How the score was calculated
  • EPSS 0.7% (30-day exploitation probability)+8
  • Technical severity (critical)+10
  • Automatable exploitation (SSVC)+3

The score orders the patch queue; it does not replace your asset context (internet exposure, criticality, compensating controls).

Triage

Is it exploited, how likely is exploitation, what does it touch, and how severe do the sources call it.

Exploitation
Not confirmed
Not in CISA KEV — an absence of record, not proof it is unexploited.
EPSS FIRST
0.65%
ahead of 50% of scored CVEs · Oct 14, 2026
Affects
Siemens
Industrial Edge Cloud Device (IECD) and 106 more
CVSS base
10.0
Critical · 2 source(s)

CISA SSVC assessment CISA

Three decision points CISA publishes for the CVEs it assesses (SSVC 2.0.3). A stakeholder decision, not a severity score.

Exploitation
None
none · proof-of-concept · active
Automatable
Yes
can an attacker script the kill-chain steps
Technical impact
Total
partial · total control of the vulnerable component

Remediation

Fixes and mitigations documented by the sources — linked to the original advisory.

No fix documented by the sources we poll. That does not mean none exists: check the vendor advisory.

First 24 hours

Ordered from the record’s own fields — exposure first, because you cannot patch what you have not found. A rule-generated starting point.

  1. Identify exposed assets running the affected vendor/product/version combinations (Siemens Industrial Edge Cloud Device (IECD), Siemens Industrial Edge Device Kit - arm64 V1.10, Siemens Industrial Edge Device Kit - arm64 V1.11…).
  2. The attack is network-based and needs no privileges: restrict exposure (ACLs, VPN, WAF) until patched.
  3. No fix documented in the sources: reduce exposure and monitor the vendor advisory.
  4. Search available logs for exploit probes matching the vulnerability class (access control), errors and authentication anomalies.

Affected scope

Vendor, product and versions as the sources word them.

VendorProductVersionsStatusSource
Siemens Industrial Edge Cloud Device (IECD) < V1.24.2 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.10 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.11 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.12 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.13 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.14 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.15 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.16 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.17 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.18 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.19 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.20 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.21 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.22 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.23 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.24 < V1.24.2 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.25 < V1.25.1 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.5 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.6 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.7 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.8 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - arm64 V1.9 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.10 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.11 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.12 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.13 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.14 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.15 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.16 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.17 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.18 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.19 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.20 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.21 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.22 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.23 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.24 < V1.24.2 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.25 < V1.25.1 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.5 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.6 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.7 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.8 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Device Kit - x86-64 V1.9 versions not specified by the source Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Own Device (IEOD) < V1.24.2 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens Industrial Edge Virtual Device (IEVD) < V1.24.2 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SCALANCE LPE9413 < V2.2 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SCALANCE LPE9433 < V2.2 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC Automation Workstation 19" < V1.3 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC Automation Workstation 24" < V1.3 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1000 Unified Comfort Panel < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1000 Unified Comfort Panel hygienic < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1000, Unified Comfort Panel neutral < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom) < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unit < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1200 Comfort Pro for support arm (not extendable, flange on top) < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1200 Comfort Pro neutral design for stand (expandable, flange at the bottom) < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (expandable, round tube) and extensio < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (not extendable, flange on top) < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1200 Unified Comfort Panel < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1200 Unified Comfort Panel hygienic < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1200 Unified Comfort Panel hygienic neutral design < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1200 Unified Comfort Panel neutral design < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1500 Comfort Pro for stand (expandable, flange at the bottom) < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1500 Comfort Pro for support arm (expandable, round tube) and extension unit < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1500 Comfort Pro for support arm (not extendable, flange on top) < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1500 Comfort Pro neutral design for stand (expandable, flange at the bottom) < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (expandable, round tube) and extensio < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (not extendable, flange on top) < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1500 Unified Comfort Panel < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1500 Unified Comfort Panel hygienic < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1500 Unified Comfort Panel hygienic neutral design < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1500 Unified Comfort Panel neutral design < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1900 Comfort Pro for stand (expandable, flange at the bottom) < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1900 Comfort Pro for support arm (expandable, round tube) and extension unit < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1900 Comfort Pro for support arm (not extendable, flange on top) < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1900 Comfort Pro neutral design for stand (expandable, flange at the bottom) < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm (expandable, round tube) and extensio < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm (not extendable, flange on top) < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1900 Unified Comfort Panel < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1900 Unified Comfort Panel hygienic < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1900 Unified Comfort Panel hygienic neutral design < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP1900 Unified Comfort Panel neutral design < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP2200 Comfort Pro for stand (expandable, flange at the bottom) < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP2200 Comfort Pro for support arm (expandable, round tube) and extension unit < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP2200 Comfort Pro for support arm (not extendable, flange on top) < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP2200 Comfort Pro neutral design for stand (expandable, flange at the bottom) < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm (expandable, round tube) and extensio < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm (not extendable, flange on top) < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP2200 Unified Comfort Hygienic < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP2200 Unified Comfort Hygienic neutral design < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP2200 Unified Comfort Panel < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP2200 Unified Comfort Panel neutral design < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP700 Unified Comfort Panel < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP700 Unified Comfort Panel hygienic neutral design < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC HMI MTP700, Unified Comfort Panel neutral design < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC IOT2050 < V1.25.1 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC IPC BX-39A Industrial Edge Device < V3.1 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC IPC BX-59A Industrial Edge Device < V3.1 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC IPC127E Industrial Edge Device < V3.1 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC IPC227E Industrial Edge Device < V3.1 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC IPC227G Industrial Edge Device < V3.1 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC IPC427E Industrial Edge Device < V3.1 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIMATIC IPC847E Industrial Edge Device < V3.1 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIPLUS HMI MTP1000 Unified Comfort < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIPLUS HMI MTP1200 Unified Comfort < V21 Vulnerable CVE Program (cve.org) e CISA ADP
Siemens SIPLUS HMI MTP700 Unified Comfort < V21 Vulnerable CVE Program (cve.org) e CISA ADP

Attack characteristics

The CVSS vector, decoded. It describes the attack, not your exposure to it.

Attack vector
Network
Attack complexity
Low
Privileges required
None
User interaction
None
Scope
Changed
Confidentiality
High
Integrity
High
Availability
High

Every base score collected

Sources score independently and may disagree; each row says who scored it and under which version.

ScoreVersionSeverityExpl.ImpactScored by
10.0 CVSS 4.0 Critical — — productcert@siemens.com via NIST National Vulnerability Database
10.0 CVSS 4.0 Critical — — siemens via CVE Program (cve.org) e CISA ADP
10.0 CVSS 3.1 Critical 3.9 6.0 productcert@siemens.com via NIST National Vulnerability Database
10.0 CVSS 3.1 Critical — — siemens via CVE Program (cve.org) e CISA ADP
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H (score shown at the top: productcert@siemens.com)

Weakness MITRE

Weakness class according to MITRE’s CWE catalog.

CWE-639 · Authorization Bypass Through User-Controlled Key (IDOR)

Other CVEs with this weakness →

EPSS over time FIRST

Oct 13, 2026 → Oct 14, 2026 · 2 reading(s) · max 0.65%

Detection

Read off the CVSS vector and the weakness class. Starting points, not tested rules.

  • Prioritize edge telemetry for the network-reachable component (proxy, WAF, IDS/IPS).
  • Audit administrative actions and access to resources outside each user’s normal pattern.
web/proxy/WAF logsnetwork IDS/IPSauthentication logsapplication logs

Timeline

What happened to this CVE, newest first.

  • 2026
  • Affected products added · siemens/industrial edge cloud device (iecd), siemens/industrial edge device kit - arm64 v1.10, siemens/industrial edge d
    Oct 13, 2026 · CVE Program (cve.org) e CISA ADP
  • SSVC assessment updated
    Oct 13, 2026 · CVE Program (cve.org) e CISA ADP
  • Record published
    Oct 13, 2026
  • CVSS changed · 10.0
    Oct 13, 2026 · NIST National Vulnerability Database
  • Source status changed · → Deferred
    Oct 13, 2026 · NIST National Vulnerability Database
  • Record created in this database
    Oct 13, 2026 · NIST National Vulnerability Database
  • CVE published
    Jan 13, 2026 · siemens

Source activity

Repeated readings are counted rather than listed.

  • 1× Official description updated · Oct 13, 2026 – Oct 13, 2026

References

2 on the record

Elsewhere on this site

Siemens
every CVE for this vendor
Access control
same class
CWE-639
other pages naming this weakness

Related CVEs (same products)

  • Critical CVE-2026-44415 Affected systems do not properly restrict access to internal APIs and paths for authenticated... 2d
  • High CVE-2026-27662 Insecure Default Initialization of Resource in Siemens SIMATIC HMI MTP1000 Unified Comfort Panel May 12, 2026

Not in any source we poll

Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.

  • No fixed version, patch or mitigation documented.
  • No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
  • No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
  • No exploit packet captures, log samples, or incident case IDs supplied.

Answered from this record

Text assembled only from the fields above — no additional claims.

What should defenders know first?

CVE-2025-40805 is "Authorization Bypass Through User-Controlled Key (IDOR) in Siemens Industrial Edge Cloud Device (IECD)", rated Critical. It affects Industrial Edge Cloud Device (IECD) (Siemens); versions are in the scope table. It is not in CISA KEV, which does not rule out exploitation. CVSS 10.0 describes technical severity. EPSS 0.65% estimates the probability of exploitation in 30 days; neither replaces your asset context. First verify whether exposed or business-critical assets run the affected versions, apply vendor fixes or mitigations, and preserve logs for review.

Comments

Moderated technical discussion. Read the community guidelines.

No comments yet.

Sign in or create an account to comment and suggest corrections.