CVE-2025-40945 — Untrusted Search Path in Siemens COMOS V10.4.5
A vulnerability has been identified in COMOS V10.4.5 (All versions < V10.4.5.0.2), COMOS V10.6 (All versions < V10.6.1), Designcenter NX (All versions < V2512.7000), Simcenter 3D (All versions < V2512.7000), Simcenter Femap V2506 (All versions < V2506.0003), Simcenter Femap V2512 (All versions < V2512.0002), Simcenter Nastran (All versions < V2606), Simcenter STAR-CCM+ (All versions < V2606), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Teamcenter Visualization V2412 (All versions < V2412.0012), Teamcenter Visualization V2506 (All versions < V2506.0009), Teamcenter Visualization V2512 (All versions < V2512.2605), Tecnomatix Plant Simulation V2404 (All versions < V2404.0022), Tecnomatix Plant Simulation V2504 (All versions < V2504.0010), Tecnomatix Process Simulate (All versions < V2606). Untrusted search path in IAM Client SDK may allow an authenticated user to potentially enable escalation of privilege via local access.
Who exploits it and how urgent it is
A 0–100 score combining confirmed exploitation, ransomware and APT use, public exploits, EPSS and severity.
How the score was calculated
- Technical severity (medium)+3
The score orders the patch queue; it does not replace your asset context (internet exposure, criticality, compensating controls).
Triage
Is it exploited, how likely is exploitation, what does it touch, and how severe do the sources call it.
CISA SSVC assessment CISA
Three decision points CISA publishes for the CVEs it assesses (SSVC 2.0.3). A stakeholder decision, not a severity score.
Remediation
Fixes and mitigations documented by the sources — linked to the original advisory.
No fix documented by the sources we poll. That does not mean none exists: check the vendor advisory.
First 24 hours
Ordered from the record’s own fields — exposure first, because you cannot patch what you have not found. A rule-generated starting point.
- Identify exposed assets running the affected vendor/product/version combinations (Siemens COMOS V10.4.5, Siemens COMOS V10.6, Siemens Designcenter NX…).
- No fix documented in the sources: reduce exposure and monitor the vendor advisory.
- Search available logs for exploit probes matching the vulnerability class (file handling), errors and authentication anomalies.
Affected scope
Vendor, product and versions as the sources word them.
| Vendor | Product | Versions | Status | Source |
|---|---|---|---|---|
| Siemens | COMOS V10.4.5 | < V10.4.5.0.2 | Vulnerable | CVE Program (cve.org) e CISA ADP |
| Siemens | COMOS V10.6 | < V10.6.1 | Vulnerable | CVE Program (cve.org) e CISA ADP |
| Siemens | Designcenter NX | < V2512.7000 | Vulnerable | CVE Program (cve.org) e CISA ADP |
| Siemens | Simcenter 3d | < V2512.7000 | Vulnerable | CVE Program (cve.org) e CISA ADP |
| Siemens | Simcenter Femap V2506 | < V2506.0003 | Vulnerable | CVE Program (cve.org) e CISA ADP |
| Siemens | Simcenter Femap V2512 | < V2512.0002 | Vulnerable | CVE Program (cve.org) e CISA ADP |
| Siemens | Simcenter Nastran | < V2606 | Vulnerable | CVE Program (cve.org) e CISA ADP |
| Siemens | Simcenter STAR-CCM+ | < V2606 | Vulnerable | CVE Program (cve.org) e CISA ADP |
| Siemens | Solid Edge Se2025 | < V225.0 Update 13 | Vulnerable | CVE Program (cve.org) e CISA ADP |
| Siemens | Solid Edge Se2026 | < V226.0 Update 04 | Vulnerable | CVE Program (cve.org) e CISA ADP |
| Siemens | Teamcenter Visualization V2412 | < V2412.0012 | Vulnerable | CVE Program (cve.org) e CISA ADP |
| Siemens | Teamcenter Visualization V2506 | < V2506.0009 | Vulnerable | CVE Program (cve.org) e CISA ADP |
| Siemens | Teamcenter Visualization V2512 | < V2512.2605 | Vulnerable | CVE Program (cve.org) e CISA ADP |
| Siemens | Tecnomatix Plant Simulation V2404 | < V2404.0022 | Vulnerable | CVE Program (cve.org) e CISA ADP |
| Siemens | Tecnomatix Plant Simulation V2504 | < V2504.0010 | Vulnerable | CVE Program (cve.org) e CISA ADP |
| Siemens | Tecnomatix Process Simulate | < V2606 | Vulnerable | CVE Program (cve.org) e CISA ADP |
Attack characteristics
The CVSS vector, decoded. It describes the attack, not your exposure to it.
Every base score collected
Sources score independently and may disagree; each row says who scored it and under which version.
| Score | Version | Severity | Expl. | Impact | Scored by |
|---|---|---|---|---|---|
| 8.5 | CVSS 4.0 | High | — | — | productcert@siemens.com via NIST National Vulnerability Database |
| 8.5 | CVSS 4.0 | High | — | — | siemens via CVE Program (cve.org) e CISA ADP |
| 6.7 | CVSS 3.1 | Medium | 0.8 | 5.9 | productcert@siemens.com via NIST National Vulnerability Database |
| 6.7 | CVSS 3.1 | Medium | — | — | siemens via CVE Program (cve.org) e CISA ADP |
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H (score shown at the top: productcert@siemens.com) Weakness MITRE
Weakness class according to MITRE’s CWE catalog.
Detection
Read off the CVSS vector and the weakness class. Starting points, not tested rules.
- Local/physical vector: focus on endpoint telemetry (EDR) from affected hosts.
- Monitor file creation in web directories and paths with traversal sequences (../).
Timeline
What happened to this CVE, newest first.
- 2026
- Affected products added · siemens/comos v10.4.5, siemens/comos v10.6, siemens/designcenter nx, siemens/simcenter 3d, siemens/simcenter femap v2506
- SSVC assessment updated
- Record published
- CVSS changed · 6.7
- Source status changed · → Deferred
- Record created in this database
- CVE published
Source activity
Repeated readings are counted rather than listed.
- 1× Official description updated · Oct 15, 2026 – Oct 15, 2026
References
1 on the record
Elsewhere on this site
Related CVEs (same products)
- High CVE-2026-59086 Stack-based Buffer Overflow in Siemens Simcenter Femap Aug 11, 2026
- High CVE-2026-50058 Out-of-bounds Read in Siemens Solid Edge Se2025 Aug 11, 2026
- High CVE-2026-50061 Use After Free in Siemens Solid Edge Se2025 Aug 11, 2026
- High CVE-2026-50060 Use After Free in Siemens Solid Edge Se2025 Aug 11, 2026
- High CVE-2026-50062 Out-of-bounds Read in Siemens Solid Edge Se2025 Aug 11, 2026
- High CVE-2026-50059 Out-of-bounds Write in Siemens Solid Edge Se2025 Aug 11, 2026
Not in any source we poll
Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.
- No FIRST EPSS score.
- No fixed version, patch or mitigation documented.
- No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
- No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
- No exploit packet captures, log samples, or incident case IDs supplied.
Answered from this record
Text assembled only from the fields above — no additional claims.
What should defenders know first?
CVE-2025-40945 is "Untrusted Search Path in Siemens COMOS V10.4.5", rated Medium. It affects COMOS V10.4.5 (Siemens); versions are in the scope table. It is not in CISA KEV, which does not rule out exploitation. CVSS 6.7 describes technical severity. First verify whether exposed or business-critical assets run the affected versions, apply vendor fixes or mitigations, and preserve logs for review.
Comments
Moderated technical discussion. Read the community guidelines.
No comments yet.
Sign in or create an account to comment and suggest corrections.