CVE-2025-59693 — Improper Privilege Management in Entrust Nshield 5c Firmware

The Chassis Management Board in Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allows a physically proximate attacker to obtain debug access and escalate privileges by bypassing the tamper label and opening the chassis without leaving evidence, and accessing the JTAG connector. This is called F02.

Published Dec 2, 2025 · Updated Oct 13, 2026 · Sources: NIST National Vulnerability Database, CVE Program (cve.org) e CISA ADP · CNA: mitre

Who exploits it and how urgent it is

A 0–100 score combining confirmed exploitation, ransomware and APT use, public exploits, EPSS and severity.

No exploitation signal in the sources consulted so far.
How the score was calculated
  • EPSS 0.9% (30-day exploitation probability)+9
  • Technical severity (critical)+10
  • CISA SSVC: exploitation "poc"+5
  • Automatable exploitation (SSVC)+3

The score orders the patch queue; it does not replace your asset context (internet exposure, criticality, compensating controls).

Triage

Is it exploited, how likely is exploitation, what does it touch, and how severe do the sources call it.

Exploitation
Not confirmed
Not in CISA KEV — an absence of record, not proof it is unexploited.
EPSS FIRST
0.9%
ahead of 59% of scored CVEs · Oct 14, 2026
Affects
Entrust
Nshield 5c Firmware and 4 more
CVSS base
9.8
Critical · 2 source(s)

CISA SSVC assessment CISA

Three decision points CISA publishes for the CVEs it assesses (SSVC 2.0.3). A stakeholder decision, not a severity score.

Exploitation
Proof of concept
none · proof-of-concept · active
Automatable
Yes
can an attacker script the kill-chain steps
Technical impact
Total
partial · total control of the vulnerable component

Remediation

Fixes and mitigations documented by the sources — linked to the original advisory.

No fix documented by the sources we poll. That does not mean none exists: check the vendor advisory.

First 24 hours

Ordered from the record’s own fields — exposure first, because you cannot patch what you have not found. A rule-generated starting point.

  1. Identify exposed assets running the affected vendor/product/version combinations (Entrust Nshield 5c Firmware, Entrust Nshield Connect Xc Base Firmware, Entrust Nshield Connect Xc High Firmware…).
  2. The attack is network-based and needs no privileges: restrict exposure (ACLs, VPN, WAF) until patched.
  3. No fix documented in the sources: reduce exposure and monitor the vendor advisory.
  4. Search available logs for exploit probes matching the vulnerability class (privilege escalation), errors and authentication anomalies.

Affected scope

Vendor, product and versions as the sources word them.

VendorProductVersionsStatusSource
Entrust Nshield 5c Firmware < 13.6.12≥ 13.7.3 and < 13.9.0 Vulnerable NIST National Vulnerability Database
Entrust Nshield Connect Xc Base Firmware < 13.6.12≥ 13.7.3 and < 13.9.0 Vulnerable NIST National Vulnerability Database
Entrust Nshield Connect Xc High Firmware < 13.6.12≥ 13.7.3 and < 13.9.0 Vulnerable NIST National Vulnerability Database
Entrust Nshield Connect Xc Mid Firmware < 13.6.12≥ 13.7.3 and < 13.9.0 Vulnerable NIST National Vulnerability Database
Entrust Nshield Hsmi Firmware < 13.6.12≥ 13.7.3 and < 13.9.0 Vulnerable NIST National Vulnerability Database

Attack characteristics

The CVSS vector, decoded. It describes the attack, not your exposure to it.

Attack vector
Network
Attack complexity
Low
Privileges required
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Every base score collected

Sources score independently and may disagree; each row says who scored it and under which version.

ScoreVersionSeverityExpl.ImpactScored by
9.8 CVSS 3.1 Critical 3.9 5.9 134c704f-9b21-4f2e-91b3-4a467353bcc0 via NIST National Vulnerability Database
9.8 CVSS 3.1 Critical — — CISA-ADP via CVE Program (cve.org) e CISA ADP
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H (score shown at the top: 134c704f-9b21-4f2e-91b3-4a467353bcc0)

Weakness MITRE

Weakness class according to MITRE’s CWE catalog.

CWE-269 · Improper Privilege Management

Other CVEs with this weakness →

EPSS over time FIRST

Oct 13, 2026 → Oct 14, 2026 · 2 reading(s) · max 0.90%

Detection

Read off the CVSS vector and the weakness class. Starting points, not tested rules.

  • Prioritize edge telemetry for the network-reachable component (proxy, WAF, IDS/IPS).
web/proxy/WAF logsnetwork IDS/IPS

Timeline

What happened to this CVE, newest first.

  • 2026
  • SSVC assessment updated
    Oct 13, 2026 · CVE Program (cve.org) e CISA ADP
  • Record published
    Oct 13, 2026
  • CVSS changed · 9.8
    Oct 13, 2026 · NIST National Vulnerability Database
  • Source status changed · → Modified
    Oct 13, 2026 · NIST National Vulnerability Database
  • Record created in this database
    Oct 13, 2026 · NIST National Vulnerability Database
  • 2025
  • CVE published
    Dec 2, 2025 · mitre

Source activity

Repeated readings are counted rather than listed.

  • 1× Official description updated · Oct 13, 2026 – Oct 13, 2026

References

4 on the record

Elsewhere on this site

Entrust
every CVE for this vendor
CWE-269
other pages naming this weakness

Related CVEs (same products)

  • Critical CVE-2025-59703 Improper Access Control in Entrust Nshield 5c Firmware Dec 2, 2025
  • Medium CVE-2025-59704 Improper Authentication in Entrust Nshield 5c Firmware Dec 2, 2025
  • Medium CVE-2025-59705 Improper Privilege Management in Entrust Nshield 5c Firmware Dec 2, 2025
  • Critical CVE-2025-59695 Missing Authentication for Critical Function in Entrust Nshield 5c Firmware Dec 2, 2025
  • Low CVE-2025-59696 Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7… Dec 2, 2025
  • High CVE-2025-59697 Improper Privilege Management in Entrust Nshield 5c Firmware Dec 2, 2025

Not in any source we poll

Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.

  • No fixed version, patch or mitigation documented.
  • No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
  • No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
  • No exploit packet captures, log samples, or incident case IDs supplied.

Answered from this record

Text assembled only from the fields above — no additional claims.

What should defenders know first?

CVE-2025-59693 is "Improper Privilege Management in Entrust Nshield 5c Firmware", rated Critical. It affects Nshield 5c Firmware (Entrust); versions are in the scope table. It is not in CISA KEV, which does not rule out exploitation. CVSS 9.8 describes technical severity. EPSS 0.90% estimates the probability of exploitation in 30 days; neither replaces your asset context. First verify whether exposed or business-critical assets run the affected versions, apply vendor fixes or mitigations, and preserve logs for review.

Comments

Moderated technical discussion. Read the community guidelines.

No comments yet.

Sign in or create an account to comment and suggest corrections.