CVE-2025-70329 — OS Command Injection in Totolink X5000r Firmware
TOTOLink X5000R v9.1.0cu_2415_B20250515 contains an OS command injection vulnerability in the setIptvCfg handler of the /usr/sbin/lighttpd executable. The vlanVidLan1 (and other vlanVidLanX) parameters are retrieved via Uci_Get_Str and passed to the CsteSystem function without adequate validation or filtering. This allows an authenticated attacker to execute arbitrary shell commands with root privileges by injecting shell metacharacters into the affected parameters.
Who exploits it and how urgent it is
A 0–100 score combining confirmed exploitation, ransomware and APT use, public exploits, EPSS and severity.
How the score was calculated
- EPSS 3.2% (30-day exploitation probability)+13
- Technical severity (high)+6
- CISA SSVC: exploitation "poc"+5
The score orders the patch queue; it does not replace your asset context (internet exposure, criticality, compensating controls).
Triage
Is it exploited, how likely is exploitation, what does it touch, and how severe do the sources call it.
CISA SSVC assessment CISA
Three decision points CISA publishes for the CVEs it assesses (SSVC 2.0.3). A stakeholder decision, not a severity score.
Remediation
Fixes and mitigations documented by the sources — linked to the original advisory.
No fix documented by the sources we poll. That does not mean none exists: check the vendor advisory.
First 24 hours
Ordered from the record’s own fields — exposure first, because you cannot patch what you have not found. A rule-generated starting point.
- Identify exposed assets running the affected vendor/product/version combinations (Totolink X5000r Firmware).
- No fix documented in the sources: reduce exposure and monitor the vendor advisory.
- Search available logs for exploit probes matching the vulnerability class (injection), errors and authentication anomalies.
Affected scope
Vendor, product and versions as the sources word them.
| Vendor | Product | Versions | Status | Source |
|---|---|---|---|---|
| Totolink | X5000r Firmware | version 9.1.0cu.2415_b20250515 | Vulnerable | NIST National Vulnerability Database |
Attack characteristics
The CVSS vector, decoded. It describes the attack, not your exposure to it.
Every base score collected
Sources score independently and may disagree; each row says who scored it and under which version.
| Score | Version | Severity | Expl. | Impact | Scored by |
|---|---|---|---|---|---|
| 8.0 | CVSS 3.1 | High | 2.1 | 5.9 | 134c704f-9b21-4f2e-91b3-4a467353bcc0 via NIST National Vulnerability Database |
| 8.0 | CVSS 3.1 | High | — | — | CISA-ADP via CVE Program (cve.org) e CISA ADP |
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H (score shown at the top: 134c704f-9b21-4f2e-91b3-4a467353bcc0) Weakness MITRE
Weakness class according to MITRE’s CWE catalog.
EPSS over time FIRST
Oct 13, 2026 → Oct 14, 2026 · 2 reading(s) · max 3.17%
Detection
Read off the CVSS vector and the weakness class. Starting points, not tested rules.
- Look for parameters with command/query metacharacters and unexpected child processes of the service.
Timeline
What happened to this CVE, newest first.
- 2026
- SSVC assessment updated
- Record published
- CVSS changed · 8.0
- Source status changed · → Analyzed
- Record created in this database
- CVE published
Source activity
Repeated readings are counted rather than listed.
- 1× Official description updated · Oct 13, 2026 – Oct 13, 2026
References
2 on the record
Elsewhere on this site
Related CVEs (same products)
- High CVE-2025-67445 Uncontrolled Resource Consumption in Totolink X5000r Firmware Feb 24, 2026
- Critical CVE-2025-70327 Argument Injection in Totolink X5000r Firmware Feb 23, 2026
- Critical CVE-2025-14586 TOTOLINK X5000R cstecgi.cgi snprintf os command injection Dec 13, 2025
- Critical CVE-2025-13184 Unauthenticated Telnet enablement via cstecgi.cgi (auth bypass) leading to unauthenticated root login with a blank password Dec 10, 2025
Not in any source we poll
Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.
- No fixed version, patch or mitigation documented.
- No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
- No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
- No exploit packet captures, log samples, or incident case IDs supplied.
Answered from this record
Text assembled only from the fields above — no additional claims.
What should defenders know first?
CVE-2025-70329 is "OS Command Injection in Totolink X5000r Firmware", rated High. It affects X5000r Firmware (Totolink); versions are in the scope table. It is not in CISA KEV, which does not rule out exploitation. CVSS 8.0 describes technical severity. EPSS 3.17% estimates the probability of exploitation in 30 days; neither replaces your asset context. First verify whether exposed or business-critical assets run the affected versions, apply vendor fixes or mitigations, and preserve logs for review.
Comments
Moderated technical discussion. Read the community guidelines.
No comments yet.
Sign in or create an account to comment and suggest corrections.