CVE-2026-11826 — OpenPLC_v3 Heap-Based Buffer Overflow in Modbus Master getData()
OpenPLC_v3 contains a heap-based buffer overflow in the getData() function in webserver/core/modbus_master.cpp. getData() reads characters between two delimiters into a caller-supplied buffer with no size parameter and no bounds check. In parseConfig() the function is invoked with the 100-byte heap-allocated MB_device.dev_name field. An authenticated attacker with access to the OpenPLC web interface can send a crafted HTTP POST to the /modbus endpoint with an oversized device_name value; the value is persisted to mbconfig.cfg and parsed on load, overflowing dev_name and overwriting adjacent struct fields (protocol at offset 108, dev_address at offset 109, ip_port at offset 210). A 200-byte payload writes 100 bytes past the allocation. The result is heap corruption leading to runtime crash and denial of service of the PLC process control loop, with attacker-controlled overwrite of adjacent configuration fields. The upstream repository was archived on 2026-04-04 and no fix is expected; the vendor has confirmed the issue does not affect OpenPLC Runtime v4.
Who exploits it and how urgent it is
A 0–100 score combining confirmed exploitation, ransomware and APT use, public exploits, EPSS and severity.
How the score was calculated
- Technical severity (high)+6
The score orders the patch queue; it does not replace your asset context (internet exposure, criticality, compensating controls).
Triage
Is it exploited, how likely is exploitation, what does it touch, and how severe do the sources call it.
CISA SSVC assessment CISA
Three decision points CISA publishes for the CVEs it assesses (SSVC 2.0.3). A stakeholder decision, not a severity score.
Remediation
Fixes and mitigations documented by the sources — linked to the original advisory.
No fix documented by the sources we poll. That does not mean none exists: check the vendor advisory.
First 24 hours
Ordered from the record’s own fields — exposure first, because you cannot patch what you have not found. A rule-generated starting point.
- Identify exposed assets running the affected vendor/product/version combinations (Openplcproject OpenPLC v3).
- No fix documented in the sources: reduce exposure and monitor the vendor advisory.
- Search available logs for exploit probes matching the vulnerability class (memory corruption), errors and authentication anomalies.
Affected scope
Vendor, product and versions as the sources word them.
| Vendor | Product | Versions | Status | Source |
|---|---|---|---|---|
| Openplcproject | OpenPLC v3 | ≤ b470206 | Vulnerable | CVE Program (cve.org) e CISA ADP |
Attack characteristics
The CVSS vector, decoded. It describes the attack, not your exposure to it.
Every base score collected
Sources score independently and may disagree; each row says who scored it and under which version.
| Score | Version | Severity | Expl. | Impact | Scored by |
|---|---|---|---|---|---|
| 8.7 | CVSS 4.0 | High | — | — | disclosure@vulncheck.com via NIST National Vulnerability Database |
| 8.7 | CVSS 4.0 | High | — | — | VulnCheck via CVE Program (cve.org) e CISA ADP |
| 8.8 | CVSS 3.1 | High | 2.8 | 5.9 | disclosure@vulncheck.com via NIST National Vulnerability Database |
| 8.8 | CVSS 3.1 | High | — | — | VulnCheck via CVE Program (cve.org) e CISA ADP |
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H (score shown at the top: disclosure@vulncheck.com) Weakness MITRE
Weakness class according to MITRE’s CWE catalog.
Detection
Read off the CVSS vector and the weakness class. Starting points, not tested rules.
- Prioritize edge telemetry for the network-reachable component (proxy, WAF, IDS/IPS).
- Correlate service crashes/restarts with inbound traffic; repeated crashes may indicate attempts.
Timeline
What happened to this CVE, newest first.
- 2026
- Affected products added · openplcproject/openplc v3
- SSVC assessment updated
- Record published
- CVSS changed · 8.8
- Source status changed · → Deferred
- Record created in this database
- CVE published
Source activity
Repeated readings are counted rather than listed.
- 1× Official description updated · Oct 15, 2026 – Oct 15, 2026
References
4 on the record
Elsewhere on this site
Not in any source we poll
Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.
- No FIRST EPSS score.
- No fixed version, patch or mitigation documented.
- No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
- No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
- No exploit packet captures, log samples, or incident case IDs supplied.
Answered from this record
Text assembled only from the fields above — no additional claims.
What should defenders know first?
CVE-2026-11826 is "OpenPLC_v3 Heap-Based Buffer Overflow in Modbus Master getData()", rated High. It affects OpenPLC v3 (Openplcproject); versions are in the scope table. It is not in CISA KEV, which does not rule out exploitation. CVSS 8.8 describes technical severity. First verify whether exposed or business-critical assets run the affected versions, apply vendor fixes or mitigations, and preserve logs for review.
Comments
Moderated technical discussion. Read the community guidelines.
No comments yet.