CVE Intelligence
High Authentication

CVE-2026-14354 — Insufficiently Protected Credentials in Schneider Electric EcoStruxure™ Cybersecurity Admin Expert

CWE-522 Insufficiently Protected Credentials vulnerability exists that could cause authentication bypass and unauthorized credential modification, potentially leading to compromise of managed devices, when a local privileged attacker leverages weaknesses in the handling and protection of stored credentials within the application.

Published Jul 29, 2026 · Updated Oct 15, 2026 · Sources: NIST National Vulnerability Database, CVE Program (cve.org) e CISA ADP · CNA: schneider

Who exploits it and how urgent it is

A 0–100 score combining confirmed exploitation, ransomware and APT use, public exploits, EPSS and severity.

No exploitation signal in the sources consulted so far.
How the score was calculated
  • EPSS 0.2% (30-day exploitation probability)+1
  • Technical severity (high)+6

The score orders the patch queue; it does not replace your asset context (internet exposure, criticality, compensating controls).

Triage

Is it exploited, how likely is exploitation, what does it touch, and how severe do the sources call it.

Exploitation
Not confirmed
Not in CISA KEV — an absence of record, not proof it is unexploited.
EPSS FIRST
0.16%
ahead of 4% of scored CVEs · Oct 15, 2026
Affects
Schneider Electric
EcoStruxure™ Cybersecurity Admin Expert
CVSS base
8.7
High · 2 source(s)

CISA SSVC assessment CISA

Three decision points CISA publishes for the CVEs it assesses (SSVC 2.0.3). A stakeholder decision, not a severity score.

Exploitation
None
none · proof-of-concept · active
Automatable
No
can an attacker script the kill-chain steps
Technical impact
Total
partial · total control of the vulnerable component

Remediation

Fixes and mitigations documented by the sources — linked to the original advisory.

No fix documented by the sources we poll. That does not mean none exists: check the vendor advisory.

First 24 hours

Ordered from the record’s own fields — exposure first, because you cannot patch what you have not found. A rule-generated starting point.

  1. Identify exposed assets running the affected vendor/product/version combinations (Schneider Electric EcoStruxure™ Cybersecurity Admin Expert).
  2. No fix documented in the sources: reduce exposure and monitor the vendor advisory.
  3. Search available logs for exploit probes matching the vulnerability class (authentication), errors and authentication anomalies.

Affected scope

Vendor, product and versions as the sources word them.

VendorProductVersionsStatusSource
Schneider Electric EcoStruxure™ Cybersecurity Admin Expert version v4.2.0 and prior Vulnerable CVE Program (cve.org) e CISA ADP

Attack characteristics

The CVSS vector, decoded. It describes the attack, not your exposure to it.

Attack vector
Local
Attack complexity
High
Attack requirements
None
Privileges required
High
User interaction
None
Scope
X
Confidentiality (vulnerable system)
High
Integrity (vulnerable system)
High
Availability (vulnerable system)
High
Confidentiality (subsequent)
High
Integrity (subsequent)
High
Availability (subsequent)
High

Every base score collected

Sources score independently and may disagree; each row says who scored it and under which version.

ScoreVersionSeverityExpl.ImpactScored by
8.7 CVSS 4.0 High — — cybersecurity@se.com via NIST National Vulnerability Database
8.7 CVSS 4.0 High — — schneider via CVE Program (cve.org) e CISA ADP
CVSS:4.0/AV:L/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X (score shown at the top: cybersecurity@se.com)

Weakness MITRE

Weakness class according to MITRE’s CWE catalog.

CWE-522 · Insufficiently Protected Credentials

Other CVEs with this weakness →

Detection

Read off the CVSS vector and the weakness class. Starting points, not tested rules.

  • Local/physical vector: focus on endpoint telemetry (EDR) from affected hosts.
  • Review authentication logs: logins without MFA, anomalous sessions and recently created accounts.
endpoint telemetry (EDR)authentication logs

Timeline

What happened to this CVE, newest first.

  • 2026
  • Affected products added · schneider electric/ecostruxure™ cybersecurity admin expert
    Oct 15, 2026 · CVE Program (cve.org) e CISA ADP
  • SSVC assessment updated
    Oct 15, 2026 · CVE Program (cve.org) e CISA ADP
  • Record published
    Oct 15, 2026
  • CVSS changed · 8.7
    Oct 15, 2026 · NIST National Vulnerability Database
  • Source status changed · → Awaiting Analysis
    Oct 15, 2026 · NIST National Vulnerability Database
  • Record created in this database
    Oct 15, 2026 · NIST National Vulnerability Database
  • CVE published
    Jul 29, 2026 · schneider

Source activity

Repeated readings are counted rather than listed.

  • 1× Official description updated · Oct 15, 2026 – Oct 15, 2026

References

1 on the record

Elsewhere on this site

Schneider Electric
every CVE for this vendor
Authentication
same class
CWE-522
other pages naming this weakness

Not in any source we poll

Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.

  • No fixed version, patch or mitigation documented.
  • No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
  • No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
  • No exploit packet captures, log samples, or incident case IDs supplied.

Answered from this record

Text assembled only from the fields above — no additional claims.

What should defenders know first?

CVE-2026-14354 is "Insufficiently Protected Credentials in Schneider Electric EcoStruxure™ Cybersecurity Admin Expert", rated High. It affects EcoStruxure™ Cybersecurity Admin Expert (Schneider Electric); versions are in the scope table. It is not in CISA KEV, which does not rule out exploitation. CVSS 8.7 describes technical severity. EPSS 0.16% estimates the probability of exploitation in 30 days; neither replaces your asset context. First verify whether exposed or business-critical assets run the affected versions, apply vendor fixes or mitigations, and preserve logs for review.

Comments

Moderated technical discussion. Read the community guidelines.

No comments yet.

Sign in or create an account to comment and suggest corrections.