CVE Intelligence
High File handling

CVE-2026-14946 — Frauscher Sensortechnik: FDS102 for FAdC/FAdCi R2 is vulnerable to Remote Code Execution via malicious configuration file.

A high privileged remote attacker can upload a .php file and then request it directly from /uploads/<filename>.php to achieve arbitrary code execution due to improper file type validation which could result in full system compromise.

Published Aug 20, 2026 · Updated Oct 15, 2026 · Sources: NIST National Vulnerability Database, CVE Program (cve.org) e CISA ADP · CNA: CERTVDE

Who exploits it and how urgent it is

A 0–100 score combining confirmed exploitation, ransomware and APT use, public exploits, EPSS and severity.

No exploitation signal in the sources consulted so far.
How the score was calculated
  • Technical severity (high)+6

The score orders the patch queue; it does not replace your asset context (internet exposure, criticality, compensating controls).

Triage

Is it exploited, how likely is exploitation, what does it touch, and how severe do the sources call it.

Exploitation
Not confirmed
Not in CISA KEV — an absence of record, not proof it is unexploited.
EPSS FIRST
—
No EPSS score.
Affects
Frauscher Sensortechnik
FDS 102
CVSS base
7.2
High · 2 source(s)

CISA SSVC assessment CISA

Three decision points CISA publishes for the CVEs it assesses (SSVC 2.0.3). A stakeholder decision, not a severity score.

Exploitation
None
none · proof-of-concept · active
Automatable
No
can an attacker script the kill-chain steps
Technical impact
Partial
partial · total control of the vulnerable component

Remediation

Fixes and mitigations documented by the sources — linked to the original advisory.

No fix documented by the sources we poll. That does not mean none exists: check the vendor advisory.

First 24 hours

Ordered from the record’s own fields — exposure first, because you cannot patch what you have not found. A rule-generated starting point.

  1. Identify exposed assets running the affected vendor/product/version combinations (Frauscher Sensortechnik FDS 102).
  2. No fix documented in the sources: reduce exposure and monitor the vendor advisory.
  3. Search available logs for exploit probes matching the vulnerability class (file handling), errors and authentication anomalies.

Affected scope

Vendor, product and versions as the sources word them.

VendorProductVersionsStatusSource
Frauscher Sensortechnik FDS 102 ≥ 2.8.0 and ≤ 2.13.3 Vulnerable CVE Program (cve.org) e CISA ADP

Attack characteristics

The CVSS vector, decoded. It describes the attack, not your exposure to it.

Attack vector
Network
Attack complexity
Low
Privileges required
High
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Every base score collected

Sources score independently and may disagree; each row says who scored it and under which version.

ScoreVersionSeverityExpl.ImpactScored by
8.6 CVSS 4.0 High — — info@cert.vde.com via NIST National Vulnerability Database
8.6 CVSS 4.0 High — — CERTVDE via CVE Program (cve.org) e CISA ADP
7.2 CVSS 3.1 High 1.2 5.9 info@cert.vde.com via NIST National Vulnerability Database
7.2 CVSS 3.1 High — — CERTVDE via CVE Program (cve.org) e CISA ADP
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H (score shown at the top: info@cert.vde.com)

Weakness MITRE

Weakness class according to MITRE’s CWE catalog.

CWE-434 · Unrestricted Upload of File with Dangerous Type

Other CVEs with this weakness →

Detection

Read off the CVSS vector and the weakness class. Starting points, not tested rules.

  • Prioritize edge telemetry for the network-reachable component (proxy, WAF, IDS/IPS).
  • Monitor file creation in web directories and paths with traversal sequences (../).
web/proxy/WAF logsnetwork IDS/IPSfile integrity (FIM)endpoint telemetry (EDR)

Timeline

What happened to this CVE, newest first.

  • 2026
  • Affected products added · frauscher sensortechnik/fds 102
    Oct 15, 2026 · CVE Program (cve.org) e CISA ADP
  • SSVC assessment updated
    Oct 15, 2026 · CVE Program (cve.org) e CISA ADP
  • Record published
    Oct 15, 2026
  • CVSS changed · 7.2
    Oct 15, 2026 · NIST National Vulnerability Database
  • Source status changed · → Deferred
    Oct 15, 2026 · NIST National Vulnerability Database
  • Record created in this database
    Oct 15, 2026 · NIST National Vulnerability Database
  • CVE published
    Aug 20, 2026 · CERTVDE

Source activity

Repeated readings are counted rather than listed.

  • 1× Official description updated · Oct 15, 2026 – Oct 15, 2026

References

1 on the record

Elsewhere on this site

Frauscher Sensortechnik
every CVE for this vendor
File handling
same class
CWE-434
other pages naming this weakness

Related CVEs (same products)

  • High CVE-2026-14948 Frauscher Sensortechnik: FDS102 for FAdC/FAdCi R2 is vulnerable to Insertion of Sensitive Information into Log File via error log archives Aug 20, 2026
  • Medium CVE-2026-14949 Frauscher Sensortechnik: FDS102 for FAdC/FAdCi R2 is vulnerable to Incorrect Authorization due to improper enforcement of role-based access control Aug 20, 2026
  • High CVE-2026-14951 Frauscher Sensortechnik: FDS102 for FAdC/FAdCi R2 is vulnerable to Cross-Site Request Forgery due to missing CSFR protection headers Aug 20, 2026
  • High CVE-2026-14952 Frauscher Sensortechnik: FDS102 for FAdC/FAdCi R2 is offering files with sensitive information for download without requiring authentication Aug 20, 2026
  • Medium CVE-2026-14953 Frauscher Sensortechnik: FDS102 for FAdC/FAdCi R2 is Missing Authorization due to improper enforcement of role-based access control Aug 20, 2026
  • High CVE-2026-14947 Frauscher Sensortechnik: FDS102 for FAdC/FAdCi R2 is vulnerable to Remote Code Execution via malicious ZIP file Aug 20, 2026

Not in any source we poll

Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.

  • No FIRST EPSS score.
  • No fixed version, patch or mitigation documented.
  • No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
  • No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
  • No exploit packet captures, log samples, or incident case IDs supplied.

Answered from this record

Text assembled only from the fields above — no additional claims.

What should defenders know first?

CVE-2026-14946 is "Frauscher Sensortechnik: FDS102 for FAdC/FAdCi R2 is vulnerable to Remote Code Execution via malicious configuration file.", rated High. It affects FDS 102 (Frauscher Sensortechnik); versions are in the scope table. It is not in CISA KEV, which does not rule out exploitation. CVSS 7.2 describes technical severity. First verify whether exposed or business-critical assets run the affected versions, apply vendor fixes or mitigations, and preserve logs for review.

Comments

Moderated technical discussion. Read the community guidelines.

No comments yet.

Sign in or create an account to comment and suggest corrections.