CVE-2026-2273 — Code Injection in Schneider Electric Ecostruxure Automation Expert

CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the workstation and a potential loss of Confidentiality, Integrity and Availability of the subsequent system when an authenticated user opens a malicious project file.

Published Mar 10, 2026 · Updated Oct 13, 2026 · Sources: NIST National Vulnerability Database, CVE Program (cve.org) e CISA ADP · CNA: schneider

Who exploits it and how urgent it is

A 0–100 score combining confirmed exploitation, ransomware and APT use, public exploits, EPSS and severity.

No exploitation signal in the sources consulted so far.
How the score was calculated
  • EPSS 0.2% (30-day exploitation probability)+2
  • Technical severity (high)+6

The score orders the patch queue; it does not replace your asset context (internet exposure, criticality, compensating controls).

Triage

Is it exploited, how likely is exploitation, what does it touch, and how severe do the sources call it.

Exploitation
Not confirmed
Not in CISA KEV — an absence of record, not proof it is unexploited.
EPSS FIRST
0.24%
ahead of 13% of scored CVEs · Oct 14, 2026
Affects
Schneider Electric
Ecostruxure Automation Expert
CVSS base
8.2
High · 3 source(s)

CISA SSVC assessment CISA

Three decision points CISA publishes for the CVEs it assesses (SSVC 2.0.3). A stakeholder decision, not a severity score.

Exploitation
None
none · proof-of-concept · active
Automatable
No
can an attacker script the kill-chain steps
Technical impact
Total
partial · total control of the vulnerable component

Remediation

Fixes and mitigations documented by the sources — linked to the original advisory.

No fix documented by the sources we poll. That does not mean none exists: check the vendor advisory.

First 24 hours

Ordered from the record’s own fields — exposure first, because you cannot patch what you have not found. A rule-generated starting point.

  1. Identify exposed assets running the affected vendor/product/version combinations (Schneider Electric Ecostruxure Automation Expert).
  2. No fix documented in the sources: reduce exposure and monitor the vendor advisory.
  3. Exploitation requires user interaction: tighten email/web filtering and warn affected users.
  4. Search available logs for exploit probes matching the vulnerability class (injection), errors and authentication anomalies.

Affected scope

Vendor, product and versions as the sources word them.

VendorProductVersionsStatusSource
Schneider Electric Ecostruxure Automation Expert < 25.0.1 Vulnerable NIST National Vulnerability Database
Schneider Electric Ecostruxure Automation Expert version Versions prior to v25.0.1 Vulnerable CVE Program (cve.org) e CISA ADP

Attack characteristics

The CVSS vector, decoded. It describes the attack, not your exposure to it.

Attack vector
Local
Attack complexity
Low
Privileges required
Low
User interaction
Required
Scope
Changed
Confidentiality
High
Integrity
High
Availability
High

Every base score collected

Sources score independently and may disagree; each row says who scored it and under which version.

ScoreVersionSeverityExpl.ImpactScored by
7.2 CVSS 4.0 High — — cybersecurity@se.com via NIST National Vulnerability Database
7.2 CVSS 4.0 High — — schneider via CVE Program (cve.org) e CISA ADP
8.2 CVSS 3.1 High 1.5 6.0 nvd@nist.gov via NIST National Vulnerability Database
CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H (score shown at the top: nvd@nist.gov)

Weakness MITRE

Weakness class according to MITRE’s CWE catalog.

CWE-94 · Code Injection

Other CVEs with this weakness →

EPSS over time FIRST

Oct 13, 2026 → Oct 14, 2026 · 2 reading(s) · max 0.24%

Detection

Read off the CVSS vector and the weakness class. Starting points, not tested rules.

  • Local/physical vector: focus on endpoint telemetry (EDR) from affected hosts.
  • Look for parameters with command/query metacharacters and unexpected child processes of the service.
endpoint telemetry (EDR)application logs

Timeline

What happened to this CVE, newest first.

  • 2026
  • Affected products added · schneider electric/ecostruxure™ automation expert
    Oct 13, 2026 · CVE Program (cve.org) e CISA ADP
  • SSVC assessment updated
    Oct 13, 2026 · CVE Program (cve.org) e CISA ADP
  • Record published
    Oct 13, 2026
  • CVSS changed · 8.2
    Oct 13, 2026 · NIST National Vulnerability Database
  • Source status changed · → Analyzed
    Oct 13, 2026 · NIST National Vulnerability Database
  • Record created in this database
    Oct 13, 2026 · NIST National Vulnerability Database
  • CVE published
    Mar 10, 2026 · schneider

Source activity

Repeated readings are counted rather than listed.

  • 1× Official description updated · Oct 13, 2026 – Oct 13, 2026

References

1 on the record

Elsewhere on this site

Schneider Electric
every CVE for this vendor
Injection
same class
CWE-94
other pages naming this weakness

Not in any source we poll

Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.

  • No fixed version, patch or mitigation documented.
  • No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
  • No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
  • No exploit packet captures, log samples, or incident case IDs supplied.

Answered from this record

Text assembled only from the fields above — no additional claims.

What should defenders know first?

CVE-2026-2273 is "Code Injection in Schneider Electric Ecostruxure Automation Expert", rated High. It affects Ecostruxure Automation Expert (Schneider Electric); versions are in the scope table. It is not in CISA KEV, which does not rule out exploitation. CVSS 8.2 describes technical severity. EPSS 0.24% estimates the probability of exploitation in 30 days; neither replaces your asset context. First verify whether exposed or business-critical assets run the affected versions, apply vendor fixes or mitigations, and preserve logs for review.

Comments

Moderated technical discussion. Read the community guidelines.

No comments yet.

Sign in or create an account to comment and suggest corrections.