CVE-2026-42804 — Stack-based Buffer Overflow in Bosch Sensortec BHI360 SensorAPI (C-Library)
A stack-based buffer overflow vulnerability exists in the Bosch Sensortec BHI360 SensorAPI(C-Library) in versions up to and including commit d6b200416a. The vulnerability is located within the FIFO parsing and debug logging subsystem inside the function bhi360_parse_debug_message() in bhi360_parse.c (lines 1852-1875). The parser trusts the first payload byte of a debug frame as the message length (msg_length) and copies that many bytes into a fixed-size 17-byte stack buffer (debug_msg) via memcpy without performing any bounds checking. A locally or physically positioned attacker (e.g., via a malicious sensor, counterfeit hardware module, or a Man-in-the-Middle on the communication bus) can exploit this vulnerability by injecting a crafted debug frame with a length byte exceeding 16. This corrupts adjacent stack data, including the saved return address. Furthermore, because the overflowed buffer is subsequently passed to a printf-style logging sink, the attacker can supply format string specifiers (e.g., %n) to execute arbitrary code on the host microcontroller/SoC or cause a reliable system crash (Denial of Service).
Who exploits it and how urgent it is
A 0–100 score combining confirmed exploitation, ransomware and APT use, public exploits, EPSS and severity.
How the score was calculated
- Technical severity (high)+6
The score orders the patch queue; it does not replace your asset context (internet exposure, criticality, compensating controls).
Triage
Is it exploited, how likely is exploitation, what does it touch, and how severe do the sources call it.
CISA SSVC assessment CISA
Three decision points CISA publishes for the CVEs it assesses (SSVC 2.0.3). A stakeholder decision, not a severity score.
Remediation
Fixes and mitigations documented by the sources — linked to the original advisory.
No fix documented by the sources we poll. That does not mean none exists: check the vendor advisory.
First 24 hours
Ordered from the record’s own fields — exposure first, because you cannot patch what you have not found. A rule-generated starting point.
- Identify exposed assets running the affected vendor/product/version combinations (Bosch Sensortec BHI360 SensorAPI (C-Library)).
- No fix documented in the sources: reduce exposure and monitor the vendor advisory.
- Search available logs for exploit probes matching the vulnerability class (memory corruption), errors and authentication anomalies.
Affected scope
Vendor, product and versions as the sources word them.
| Vendor | Product | Versions | Status | Source |
|---|---|---|---|---|
| Bosch Sensortec | BHI360 SensorAPI (C-Library) | ≥ 2.1.0 and ≤ 2.2.0 | Vulnerable | CVE Program (cve.org) e CISA ADP |
Attack characteristics
The CVSS vector, decoded. It describes the attack, not your exposure to it.
Every base score collected
Sources score independently and may disagree; each row says who scored it and under which version.
| Score | Version | Severity | Expl. | Impact | Scored by |
|---|---|---|---|---|---|
| 7.6 | CVSS 3.1 | High | 0.9 | 6.0 | psirt@bosch.com via NIST National Vulnerability Database |
| 7.6 | CVSS 3.1 | High | — | — | bosch via CVE Program (cve.org) e CISA ADP |
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H (score shown at the top: psirt@bosch.com) Weakness MITRE
Weakness class according to MITRE’s CWE catalog.
Detection
Read off the CVSS vector and the weakness class. Starting points, not tested rules.
- Local/physical vector: focus on endpoint telemetry (EDR) from affected hosts.
- Correlate service crashes/restarts with inbound traffic; repeated crashes may indicate attempts.
Timeline
What happened to this CVE, newest first.
- 2026
- Affected products added · bosch sensortec/bhi360 sensorapi (c-library)
- SSVC assessment updated
- Record published
- CVSS changed · 7.6
- Source status changed · → Awaiting Analysis
- Record created in this database
- CVE published
Source activity
Repeated readings are counted rather than listed.
- 1× Official description updated · Oct 15, 2026 – Oct 15, 2026
References
1 on the record
Elsewhere on this site
Not in any source we poll
Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.
- No FIRST EPSS score.
- No fixed version, patch or mitigation documented.
- No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
- No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
- No exploit packet captures, log samples, or incident case IDs supplied.
Answered from this record
Text assembled only from the fields above — no additional claims.
What should defenders know first?
CVE-2026-42804 is "Stack-based Buffer Overflow in Bosch Sensortec BHI360 SensorAPI (C-Library)", rated High. It affects BHI360 SensorAPI (C-Library) (Bosch Sensortec); versions are in the scope table. It is not in CISA KEV, which does not rule out exploitation. CVSS 7.6 describes technical severity. First verify whether exposed or business-critical assets run the affected versions, apply vendor fixes or mitigations, and preserve logs for review.
Comments
Moderated technical discussion. Read the community guidelines.
No comments yet.
Sign in or create an account to comment and suggest corrections.