CVE Intelligence
Medium Memory corruption

CVE-2026-42806 — Out-of-bounds Read in Bosch Sensortec BME690 SensorAPI (C)

An out-of-bounds read vulnerability was discovered in the Bosch BME690 SensorAPI (C-driver) in version v1.0.3 and prior, specifically within the field data parsing logic in read_all_field_data (bme69x.c). The driver prefetches heater configuration registers into a contiguous 30-byte stack buffer (set_val) mapping IDAC, RES_HEAT, and GAS_WAIT tables. When parsing sensor field data, the gas_index is extracted using a 4-bit mask (0..15) but lacks boundary verification against the valid range (0..9). An attacker or a compromised peripheral mimicking a sensor on the I2C/SPI bus could return a payload with a gas index value of 10 or higher. This causes the driver to perform an out-of-bounds array access (set_val[20 + gas_index]), reading up to 6 bytes past the stack buffer. The leaked out-of-bounds byte is then written into the public gas_wait field, which may lead to measurement corruption or leak adjacent stack memory when telemetered or logged.

Published Sep 10, 2026 · Updated Oct 15, 2026 · Sources: NIST National Vulnerability Database, CVE Program (cve.org) e CISA ADP · CNA: bosch

Who exploits it and how urgent it is

A 0–100 score combining confirmed exploitation, ransomware and APT use, public exploits, EPSS and severity.

No exploitation signal in the sources consulted so far.
How the score was calculated
  • Technical severity (medium)+3

The score orders the patch queue; it does not replace your asset context (internet exposure, criticality, compensating controls).

Triage

Is it exploited, how likely is exploitation, what does it touch, and how severe do the sources call it.

Exploitation
Not confirmed
Not in CISA KEV — an absence of record, not proof it is unexploited.
EPSS FIRST
—
No EPSS score.
Affects
Bosch Sensortec
BME690 SensorAPI (C)
CVSS base
4.3
Medium · 2 source(s)

CISA SSVC assessment CISA

Three decision points CISA publishes for the CVEs it assesses (SSVC 2.0.3). A stakeholder decision, not a severity score.

Exploitation
None
none · proof-of-concept · active
Automatable
No
can an attacker script the kill-chain steps
Technical impact
Partial
partial · total control of the vulnerable component

Remediation

Fixes and mitigations documented by the sources — linked to the original advisory.

No fix documented by the sources we poll. That does not mean none exists: check the vendor advisory.

First 24 hours

Ordered from the record’s own fields — exposure first, because you cannot patch what you have not found. A rule-generated starting point.

  1. Identify exposed assets running the affected vendor/product/version combinations (Bosch Sensortec BME690 SensorAPI (C)).
  2. No fix documented in the sources: reduce exposure and monitor the vendor advisory.
  3. Search available logs for exploit probes matching the vulnerability class (memory corruption), errors and authentication anomalies.

Affected scope

Vendor, product and versions as the sources word them.

VendorProductVersionsStatusSource
Bosch Sensortec BME690 SensorAPI (C) ≥ 1.0.1 and ≤ 1.0.3 Vulnerable CVE Program (cve.org) e CISA ADP

Attack characteristics

The CVSS vector, decoded. It describes the attack, not your exposure to it.

Attack vector
Physical
Attack complexity
Low
Privileges required
None
User interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
Low
Availability
Low

Every base score collected

Sources score independently and may disagree; each row says who scored it and under which version.

ScoreVersionSeverityExpl.ImpactScored by
4.3 CVSS 3.1 Medium 0.9 3.4 psirt@bosch.com via NIST National Vulnerability Database
4.3 CVSS 3.1 Medium — — bosch via CVE Program (cve.org) e CISA ADP
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L (score shown at the top: psirt@bosch.com)

Weakness MITRE

Weakness class according to MITRE’s CWE catalog.

CWE-125 · Out-of-bounds Read

Other CVEs with this weakness →

Detection

Read off the CVSS vector and the weakness class. Starting points, not tested rules.

  • Local/physical vector: focus on endpoint telemetry (EDR) from affected hosts.
  • Correlate service crashes/restarts with inbound traffic; repeated crashes may indicate attempts.
endpoint telemetry (EDR)crash dumps

Timeline

What happened to this CVE, newest first.

  • 2026
  • Affected products added · bosch sensortec/bme690 sensorapi (c)
    Oct 15, 2026 · CVE Program (cve.org) e CISA ADP
  • SSVC assessment updated
    Oct 15, 2026 · CVE Program (cve.org) e CISA ADP
  • Record published
    Oct 15, 2026
  • CVSS changed · 4.3
    Oct 15, 2026 · NIST National Vulnerability Database
  • Source status changed · → Awaiting Analysis
    Oct 15, 2026 · NIST National Vulnerability Database
  • Record created in this database
    Oct 15, 2026 · NIST National Vulnerability Database
  • CVE published
    Sep 10, 2026 · bosch

Source activity

Repeated readings are counted rather than listed.

  • 1× Official description updated · Oct 15, 2026 – Oct 15, 2026

References

1 on the record

Elsewhere on this site

Bosch Sensortec
every CVE for this vendor
CWE-125
other pages naming this weakness

Not in any source we poll

Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.

  • No FIRST EPSS score.
  • No fixed version, patch or mitigation documented.
  • No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
  • No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
  • No exploit packet captures, log samples, or incident case IDs supplied.

Answered from this record

Text assembled only from the fields above — no additional claims.

What should defenders know first?

CVE-2026-42806 is "Out-of-bounds Read in Bosch Sensortec BME690 SensorAPI (C)", rated Medium. It affects BME690 SensorAPI (C) (Bosch Sensortec); versions are in the scope table. It is not in CISA KEV, which does not rule out exploitation. CVSS 4.3 describes technical severity. First verify whether exposed or business-critical assets run the affected versions, apply vendor fixes or mitigations, and preserve logs for review.

Comments

Moderated technical discussion. Read the community guidelines.

No comments yet.