CVE-2026-52866 — Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT Missing Authorization
An attacker within BLE communication range can monopolize the device's only available BLE connection slot, preventing legitimate users or applications from establishing a connection.
Who exploits it and how urgent it is
A 0–100 score combining confirmed exploitation, ransomware and APT use, public exploits, EPSS and severity.
How the score was calculated
- EPSS 0.3% (30-day exploitation probability)+4
- Technical severity (medium)+3
The score orders the patch queue; it does not replace your asset context (internet exposure, criticality, compensating controls).
Triage
Is it exploited, how likely is exploitation, what does it touch, and how severe do the sources call it.
CISA SSVC assessment CISA
Three decision points CISA publishes for the CVEs it assesses (SSVC 2.0.3). A stakeholder decision, not a severity score.
Remediation
Fixes and mitigations documented by the sources — linked to the original advisory.
No fix documented by the sources we poll. That does not mean none exists: check the vendor advisory.
First 24 hours
Ordered from the record’s own fields — exposure first, because you cannot patch what you have not found. A rule-generated starting point.
- Identify exposed assets running the affected vendor/product/version combinations (Apollo Pharmacy Blood Glucose Monitoring System (Model No. APG-01 BT)).
- No fix documented in the sources: reduce exposure and monitor the vendor advisory.
- Search available logs for exploit probes matching the vulnerability class (access control), errors and authentication anomalies.
Affected scope
Vendor, product and versions as the sources word them.
| Vendor | Product | Versions | Status | Source |
|---|---|---|---|---|
| Apollo Pharmacy | Blood Glucose Monitoring System (Model No. APG-01 BT) | version 0x0110_v1.1.0 | Vulnerable | CVE Program (cve.org) e CISA ADP |
Attack characteristics
The CVSS vector, decoded. It describes the attack, not your exposure to it.
Every base score collected
Sources score independently and may disagree; each row says who scored it and under which version.
| Score | Version | Severity | Expl. | Impact | Scored by |
|---|---|---|---|---|---|
| 7.1 | CVSS 4.0 | High | — | — | ics-cert@hq.dhs.gov via NIST National Vulnerability Database |
| 7.1 | CVSS 4.0 | High | — | — | icscert via CVE Program (cve.org) e CISA ADP |
| 6.5 | CVSS 3.1 | Medium | 2.8 | 3.6 | ics-cert@hq.dhs.gov via NIST National Vulnerability Database |
| 6.5 | CVSS 3.1 | Medium | — | — | icscert via CVE Program (cve.org) e CISA ADP |
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (score shown at the top: ics-cert@hq.dhs.gov) Weakness MITRE
Weakness class according to MITRE’s CWE catalog.
EPSS over time FIRST
Oct 13, 2026 → Oct 14, 2026 · 2 reading(s) · max 0.35%
Detection
Read off the CVSS vector and the weakness class. Starting points, not tested rules.
- Audit administrative actions and access to resources outside each user’s normal pattern.
Timeline
What happened to this CVE, newest first.
- 2026
- Affected products added · apollo pharmacy/blood glucose monitoring system (model no. apg-01 bt)
- SSVC assessment updated
- Record published
- CVSS changed · 6.5
- Source status changed · → Awaiting Analysis
- Record created in this database
- CVE published
Source activity
Repeated readings are counted rather than listed.
- 1× Official description updated · Oct 13, 2026 – Oct 13, 2026
References
4 on the record
Elsewhere on this site
Related CVEs (same products)
- Medium CVE-2026-50034 Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT Cleartext Transmission of Sensitive Information Jun 18, 2026
Not in any source we poll
Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.
- No fixed version, patch or mitigation documented.
- No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
- No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
- No exploit packet captures, log samples, or incident case IDs supplied.
Answered from this record
Text assembled only from the fields above — no additional claims.
What should defenders know first?
CVE-2026-52866 is "Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT Missing Authorization", rated Medium. It affects Blood Glucose Monitoring System (Model No. APG-01 BT) (Apollo Pharmacy); versions are in the scope table. It is not in CISA KEV, which does not rule out exploitation. CVSS 6.5 describes technical severity. EPSS 0.35% estimates the probability of exploitation in 30 days; neither replaces your asset context. First verify whether exposed or business-critical assets run the affected versions, apply vendor fixes or mitigations, and preserve logs for review.
Comments
Moderated technical discussion. Read the community guidelines.
No comments yet.
Sign in or create an account to comment and suggest corrections.