CVE-2026-78327 — OS Command Injection in Sonicwall Network Security Manager (NSM)
An Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in the SonicWall Network Security Manager (NSM) On-Prem Management interface allows an authenticated attacker with SuperAdmin privileges to inject arbitrary commands that are executed on the underlying host, resulting in remote code execution.
Who exploits it and how urgent it is
A 0–100 score combining confirmed exploitation, ransomware and APT use, public exploits, EPSS and severity.
How the score was calculated
- Technical severity (critical)+10
The score orders the patch queue; it does not replace your asset context (internet exposure, criticality, compensating controls).
Triage
Is it exploited, how likely is exploitation, what does it touch, and how severe do the sources call it.
CISA SSVC assessment CISA
Three decision points CISA publishes for the CVEs it assesses (SSVC 2.0.3). A stakeholder decision, not a severity score.
Remediation
Fixes and mitigations documented by the sources — linked to the original advisory.
No fix documented by the sources we poll. That does not mean none exists: check the vendor advisory.
First 24 hours
Ordered from the record’s own fields — exposure first, because you cannot patch what you have not found. A rule-generated starting point.
- Identify exposed assets running the affected vendor/product/version combinations (Sonicwall Network Security Manager (NSM)).
- No fix documented in the sources: reduce exposure and monitor the vendor advisory.
- Search available logs for exploit probes matching the vulnerability class (injection), errors and authentication anomalies.
Affected scope
Vendor, product and versions as the sources word them.
| Vendor | Product | Versions | Status | Source |
|---|---|---|---|---|
| Sonicwall | Network Security Manager (NSM) | version 4.3.0 and earlier versions | Vulnerable | CVE Program (cve.org) e CISA ADP |
Attack characteristics
The CVSS vector, decoded. It describes the attack, not your exposure to it.
Every base score collected
Sources score independently and may disagree; each row says who scored it and under which version.
| Score | Version | Severity | Expl. | Impact | Scored by |
|---|---|---|---|---|---|
| 9.1 | CVSS 3.1 | Critical | 2.3 | 6.0 | 134c704f-9b21-4f2e-91b3-4a467353bcc0 via NIST National Vulnerability Database |
| 9.1 | CVSS 3.1 | Critical | — | — | CISA-ADP via CVE Program (cve.org) e CISA ADP |
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H (score shown at the top: 134c704f-9b21-4f2e-91b3-4a467353bcc0) Weakness MITRE
Weakness class according to MITRE’s CWE catalog.
Detection
Read off the CVSS vector and the weakness class. Starting points, not tested rules.
- Prioritize edge telemetry for the network-reachable component (proxy, WAF, IDS/IPS).
- Look for parameters with command/query metacharacters and unexpected child processes of the service.
Timeline
What happened to this CVE, newest first.
- 2026
- Affected products added · sonicwall/network security manager (nsm)
- SSVC assessment updated
- Record published
- CVSS changed · 9.1
- Source status changed · → Awaiting Analysis
- Record created in this database
- CVE published
Source activity
Repeated readings are counted rather than listed.
- 1× Official description updated · Oct 15, 2026 – Oct 15, 2026
References
1 on the record
Elsewhere on this site
Related CVEs (same products)
- High CVE-2026-96540 An improper access control vulnerability has been identified in the SonicWall Network Security... 1d
- High CVE-2026-100232 Post-authentication Improper Neutralization of Special Elements used in an OS Command ('OS... 1d
- Critical CVE-2026-81939 Path Traversal in Sonicwall Network Security Manager (NSM) Sep 4, 2026
- Critical CVE-2026-78328 Missing Authorization in Sonicwall Network Security Manager (NSM) Sep 4, 2026
Not in any source we poll
Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.
- No FIRST EPSS score.
- No fixed version, patch or mitigation documented.
- No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
- No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
- No exploit packet captures, log samples, or incident case IDs supplied.
Answered from this record
Text assembled only from the fields above — no additional claims.
What should defenders know first?
CVE-2026-78327 is "OS Command Injection in Sonicwall Network Security Manager (NSM)", rated Critical. It affects Network Security Manager (NSM) (Sonicwall); versions are in the scope table. It is not in CISA KEV, which does not rule out exploitation. CVSS 9.1 describes technical severity. First verify whether exposed or business-critical assets run the affected versions, apply vendor fixes or mitigations, and preserve logs for review.