CVE-2026-89472 — power: supply: charger-manager: register regulators before exposing sysfs
In the Linux kernel, the following vulnerability has been resolved: power: supply: charger-manager: register regulators before exposing sysfs charger_manager_remove() and the err_reg_extcon probe error path free each charger regulator with regulator_put() before tearing down the power_supply sysfs entries (power_supply_unregister()). charger_manager_remove() also calls try_charger_enable(cm, false) after the regulator_put() loop. A concurrent write to a charger's externally_control sysfs attribute that lands between regulator_put() and power_supply_unregister() can run charger_externally_control_store() and call try_charger_enable(), which, when charging is enabled, dereferences the already-freed consumer handle. When charging is enabled, try_charger_enable(cm, false) in .remove() also dereferences the freed handles directly. Both leave use-after-free windows. Symmetrically, probe registers the sysfs entries (power_supply_register) before acquiring the regulators (regulator_get, inside charger_manager_register_extcon), so userspace can reach externally_control before the regulators are available. Split charger_manager_register_extcon() on the sync/async boundary: charger_manager_get_regulators() (regulator_get only, no async producer) now runs before power_supply_register() so sysfs is not live before regulators are available, and charger_manager_register_extcon() keeps only the extcon notifier/work setup, still after power_supply_register() so a power_supply_register() failure cannot reach extcon setup. This keeps the sysfs setup/teardown ordering symmetric without introducing an asynchronous producer on the earlier probe-error path. Move power_supply_unregister() and try_charger_enable(cm, false) ahead of the regulator_put() loop on both teardown paths, and adjust err_reg_extcon (power_supply_unregister() then fall through err_regulator for regulator_put(); get_regulators self-rolls back on its own failure). This does not address the separate extcon-notifier-driven deref of the same handles, which needs its own synchronization design. Found by an in-house static analysis tool.
Who exploits it and how urgent it is
A 0–100 score combining confirmed exploitation, ransomware and APT use, public exploits, EPSS and severity.
How the score was calculated
- Technical severity (high)+6
The score orders the patch queue; it does not replace your asset context (internet exposure, criticality, compensating controls).
Triage
Is it exploited, how likely is exploitation, what does it touch, and how severe do the sources call it.
Remediation
Fixes and mitigations documented by the sources — linked to the original advisory.
No fix documented by the sources we poll. That does not mean none exists: check the vendor advisory.
First 24 hours
Ordered from the record’s own fields — exposure first, because you cannot patch what you have not found. A rule-generated starting point.
- Identify exposed assets running the affected vendor/product/version combinations (Linux Linux).
- No fix documented in the sources: reduce exposure and monitor the vendor advisory.
- Search available logs for exploit probes, errors and authentication anomalies.
Affected scope
Vendor, product and versions as the sources word them.
| Vendor | Product | Versions | Status | Source |
|---|---|---|---|---|
| Linux | Linux | ≥ 3950c7865cd7c963982a2c94457182b96732f4c9 and < af3ce383ba0d0d48957a22ac7058ff5698775898≥ 3950c7865cd7c963982a2c94457182b96732f4c9 and < 86e4fa65368f3bbb506dddba8c9eedc75bd603b2≥ 3950c7865cd7c963982a2c94457182b96732f4c9 and < 6d532582ff3c420598f02945b13184c738cc1581≥ 3950c7865cd7c963982a2c94457182b96732f4c9 and < c57cb36f76eb7ced45f57af1a890d8f3a6d76342version 3.7 | Vulnerable | CVE Program (cve.org) e CISA ADP |
Attack characteristics
The CVSS vector, decoded. It describes the attack, not your exposure to it.
Every base score collected
Sources score independently and may disagree; each row says who scored it and under which version.
| Score | Version | Severity | Expl. | Impact | Scored by |
|---|---|---|---|---|---|
| 7.8 | CVSS 3.1 | High | 1.8 | 5.9 | 416baaa9-dc9f-4396-8d5f-8c081fb06d67 via NIST National Vulnerability Database |
| 7.8 | CVSS 3.1 | High | — | — | Linux via CVE Program (cve.org) e CISA ADP |
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H (score shown at the top: 416baaa9-dc9f-4396-8d5f-8c081fb06d67) Detection
Read off the CVSS vector and the weakness class. Starting points, not tested rules.
- Local/physical vector: focus on endpoint telemetry (EDR) from affected hosts.
Timeline
What happened to this CVE, newest first.
- 2026
- Affected products added · linux/linux
- Record published
- CVSS changed · 7.8
- Source status changed · → Received
- Record created in this database
- CVE published
Source activity
Repeated readings are counted rather than listed.
- 1× Official description updated · Oct 15, 2026 – Oct 15, 2026
References
4 on the record
Elsewhere on this site
Related CVEs (same products)
- Critical CVE-2026-99999 ipv4: validate checksum_start before completing checksum 14h
- Unknown CVE-2026-98432 ipv4: free inet_opt and ireq_opt after an RCU grace period 14h
- Unknown CVE-2026-98424 wifi: cfg80211: undo netns switch if renaming the wiphy fails 1d
- Unknown CVE-2026-98425 wifi: mac80211: don't warn when an IBSS has no channel to scan 1d
- Unknown CVE-2026-98426 wifi: mwifiex: fix IRQ leak using wrong index in MSI-X error path 1d
- Unknown CVE-2026-98427 net/sched: codel: bound the dropping loop per dequeue call 1d
Not in any source we poll
Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.
- No FIRST EPSS score.
- No fixed version, patch or mitigation documented.
- No CISA SSVC assessment.
- No CWE classification.
- No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
- No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
- No exploit packet captures, log samples, or incident case IDs supplied.
Answered from this record
Text assembled only from the fields above — no additional claims.
What should defenders know first?
CVE-2026-89472 is "power: supply: charger-manager: register regulators before exposing sysfs", rated High. It affects Linux (Linux); versions are in the scope table. It is not in CISA KEV, which does not rule out exploitation. CVSS 7.8 describes technical severity. First verify whether exposed or business-critical assets run the affected versions, apply vendor fixes or mitigations, and preserve logs for review.
Comments
Moderated technical discussion. Read the community guidelines.
No comments yet.
Sign in or create an account to comment and suggest corrections.