CVE Intelligence
Home / CVEs

CVE Database

Published vulnerabilities with severity, known exploitation and official sources.

Severity
Clear

1.617 result(s)

Export this search: RSS · CSV · STIX
CVE-2025-11549 Critical · 9.8 CWE-119 Oct 9, 2025
Tenda W12 HTTP Request modules wifiMacFilterSet stack-based overflow
A vulnerability has been found in Tenda W12 3.0.0.6(3948). The affected element is the function wifiMacFilterSet of the file /goform/modules of the component HTTP Request Handler. The manipulation of the argument mac leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-11528 High · 8.8 CWE-119 Oct 9, 2025
Tenda AC7 saveAutoQos stack-based overflow
A vulnerability was identified in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/saveAutoQos. The manipulation of the argument enable leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
CVE-2025-11527 High · 8.8 CWE-119 Oct 9, 2025
Tenda AC7 fast_setting_pppoe_set stack-based overflow
A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing a manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.
CVE-2025-11526 High · 8.8 CWE-119 Oct 9, 2025
Tenda AC7 WifiMacFilterSet stack-based overflow
A vulnerability was found in Tenda AC7 15.03.06.44. The affected element is an unknown function of the file /goform/WifiMacFilterSet. Performing a manipulation of the argument wifi_chkHz results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used.
CVE-2025-11525 High · 8.8 CWE-119 Oct 8, 2025
Tenda AC7 SetUpnpCfg stack-based overflow
A vulnerability has been found in Tenda AC7 15.03.06.44. Impacted is an unknown function of the file /goform/SetUpnpCfg. Such manipulation of the argument upnpEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-11524 High · 8.8 CWE-119 Oct 8, 2025
Tenda AC7 SetDDNSCfg stack-based overflow
A flaw has been found in Tenda AC7 15.03.06.44. This issue affects some unknown processing of the file /goform/SetDDNSCfg. This manipulation of the argument ddnsEn causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been published and may be used.
CVE-2025-11495 Medium · 5.5 CWE-119 Oct 8, 2025
GNU Binutils Linker elf64-x86-64.c elf_x86_64_relocate_section heap-based overflow
A vulnerability was determined in GNU Binutils 2.45. The affected element is the function elf_x86_64_relocate_section of the file elf64-x86-64.c of the component Linker. This manipulation causes heap-based buffer overflow. The attack can only be executed locally. The exploit has been publicly disclosed and may be utilized. Patch name: 6b21c8b2ecfef5c95142cbc2c32f185cb1c26ab0. To fix this issue, it is recommended to deploy a patch.
CVE-2025-11444 High · 8.8 CWE-119 Oct 8, 2025
TOTOLINK N600R HTTP Request cstecgi.cgi setWiFiBasicConfig buffer overflow
A security vulnerability has been detected in TOTOLINK N600R up to 4.3.0cu.7866_B20220506. This impacts the function setWiFiBasicConfig of the file /cgi-bin/cstecgi.cgi of the component HTTP Request Handler. Such manipulation of the argument wepkey leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed publicly and may be used.
CVE-2025-11423 Critical · 9.8 CWE-119 Oct 7, 2025
Tenda CH22 SafeEmailFilter formSafeEmailFilter memory corruption
A vulnerability was found in Tenda CH22 1.0.0.1. This affects the function formSafeEmailFilter of the file /goform/SafeEmailFilter. Performing a manipulation of the argument page results in memory corruption. The attack is possible to be carried out remotely. The exploit has been made public and could be used.
CVE-2025-11418 Critical · 9.8 CWE-119 Oct 7, 2025
Tenda CH22 HTTP Request AdvSetWrlsafeset formWrlsafeset stack-based overflow
A security vulnerability has been detected in Tenda CH22 up to 1.0.0.1. This issue affects the function formWrlsafeset of the file /goform/AdvSetWrlsafeset of the component HTTP Request Handler. The manipulation of the argument mit_ssid_index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used.
CVE-2025-11408 Critical · 9.8 CWE-119 Oct 7, 2025
D-Link DI-7001 MINI dbsrv.asp buffer overflow
A security vulnerability has been detected in D-Link DI-7001 MINI 24.04.18B1. The affected element is an unknown function of the file /dbsrv.asp. Such manipulation of the argument str leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used.
CVE-2025-36156 High · 7.8 CWE-119 Oct 7, 2025
IBM InfoSphere Data Replication VSAM for z/OS Remote Source code execution
IBM InfoSphere Data Replication VSAM for z/OS Remote Source 11.4 is vulnerable to a stack-based buffer overflow, caused by improper bounds checking. A local user with access to the files storing CECSUB or CECRM on the container could overflow the buffer and execute arbitrary code on the system.
CVE-2025-11389 High · 8.8 CWE-119 Oct 7, 2025
Tenda AC15 saveAutoQos stack-based overflow
A security flaw has been discovered in Tenda AC15 15.03.05.18. Affected is an unknown function of the file /goform/saveAutoQos. Performing a manipulation of the argument enable results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks.
CVE-2025-11388 High · 8.8 CWE-119 Oct 7, 2025
Tenda AC15 setNotUpgrade stack-based overflow
A vulnerability was identified in Tenda AC15 15.03.05.18. This impacts an unknown function of the file /goform/setNotUpgrade. Such manipulation of the argument newVersion leads to stack-based buffer overflow. The attack may be launched remotely. The exploit is publicly available and might be used.
CVE-2025-11387 High · 8.8 CWE-119 Oct 7, 2025
Tenda AC15 fast_setting_pppoe_set stack-based overflow
A vulnerability was determined in Tenda AC15 15.03.05.18. This affects an unknown function of the file /goform/fast_setting_pppoe_set. This manipulation of the argument Password causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.
CVE-2025-11386 High · 8.8 CWE-119 Oct 7, 2025
Tenda AC15 POST Parameter SetDDNSCfg stack-based overflow
A vulnerability was found in Tenda AC15 15.03.05.18. The impacted element is an unknown function of the file /goform/SetDDNSCfg of the component POST Parameter Handler. The manipulation of the argument ddnsEn results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.
CVE-2025-11385 High · 8.8 CWE-119 Oct 7, 2025
Tenda AC20 fast_setting_wifi_set sscanf buffer overflow
A vulnerability has been found in Tenda AC20 up to 16.03.08.12. The affected element is the function sscanf of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-11356 High · 8.8 CWE-119 Oct 7, 2025
Tenda AC23 SetStaticRouteCfg sscanf buffer overflow
A vulnerability was found in Tenda AC23 up to 16.03.07.52. Affected by this issue is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. It is possible to launch the attack remotely. The exploit has been made public and could be used.
CVE-2025-11355 High · 8.8 CWE-119 Oct 7, 2025
UTT 1250GW aspChangeChannel strcpy buffer overflow
A vulnerability has been found in UTT 1250GW up to v2v3.2.2-200710. Affected by this vulnerability is the function strcpy of the file /goform/aspChangeChannel. The manipulation of the argument pvid leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-11339 High · 8.8 CWE-119 Oct 6, 2025
D-Link DI-7100G C1 jhttpd hi_block.asp sub_4BD4F8 buffer overflow
A vulnerability has been found in D-Link DI-7100G C1 up to 20250928. This issue affects the function sub_4BD4F8 of the file /webchat/hi_block.asp of the component jhttpd. The manipulation of the argument popupId leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-11338 Critical · 9.8 CWE-119 Oct 6, 2025
D-Link DI-7100G C1 jhttpd login.cgi sub_4C0990 buffer overflow
A flaw has been found in D-Link DI-7100G C1 up to 20250928. This vulnerability affects the function sub_4C0990 of the file /webchat/login.cgi of the component jhttpd. Executing manipulation of the argument openid can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used.
CVE-2025-11328 High · 8.8 CWE-119 Oct 6, 2025
Tenda AC18 SetDDNSCfg stack-based overflow
A vulnerability was detected in Tenda AC18 15.03.05.19(6318). This issue affects some unknown processing of the file /goform/SetDDNSCfg. The manipulation of the argument ddnsEn results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is now public and may be used.
CVE-2025-11327 High · 8.8 CWE-119 Oct 6, 2025
Tenda AC18 SetUpnpCfg stack-based overflow
A security vulnerability has been detected in Tenda AC18 15.03.05.19(6318). This vulnerability affects unknown code of the file /goform/SetUpnpCfg. The manipulation of the argument upnpEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used.
CVE-2025-11326 High · 8.8 CWE-119 Oct 6, 2025
Tenda AC18 WifiMacFilterSet stack-based overflow
A weakness has been identified in Tenda AC18 15.03.05.19(6318). This affects an unknown part of the file /goform/WifiMacFilterSet. Executing a manipulation of the argument wifi_chkHz can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been made available to the public and could be used for attacks.
CVE-2025-11325 High · 8.8 CWE-119 Oct 6, 2025
Tenda AC18 fast_setting_pppoe_set stack-based overflow
A security flaw has been discovered in Tenda AC18 15.03.05.19(6318). Affected by this issue is some unknown functionality of the file /goform/fast_setting_pppoe_set. Performing a manipulation of the argument Username results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks.