Hitachi Energy vulnerabilities
Published CVEs affecting Hitachi Energy products: 20 record(s), with severity, exploitation and fixes.
RTU500 series CMU firmware 7TropOS 4th Gen 3Microscada X Sys600 3MicroSCADA SYS600 3Rtu520 Firmware 2Rtu530 Firmware 2Rtu540 Firmware 2Rtu560 Firmware 2Reb500 Firmware 2Relion REB500 2Asset Suite 2SuprOS 1PROMOD V 1MACH HiDraw 1
CVE-2026-8067
Medium · 6.5
CWE-862 Sep 29, 2026
Missing Authorization in Hitachi Energy RTU500 series CMU firmware
An improper authorization vulnerability in the end-of-life versions of RTU500’s web application allows an authenticated user to trigger the RTU500 to reboot through the reset endpoint. Successful exploitation could cause temporary device unavailability and disruption of its intended operation.
CVE-2026-8066
Critical · 9.1
CWE-23 Sep 29, 2026
Relative Path Traversal in Hitachi Energy RTU500 series CMU firmware
A directory traversal vulnerability in the file upload functionality of Hitachi Energy RTU500 end-of-life versions allows an unauthenticated attacker to write or overwrite arbitrary files on the device file system. Depending on the files affected, successful exploitation could result in unauthorized modification of device data or disruption of the device’s intended operation.
CVE-2026-8065
Critical · 9.1
CWE-306 Sep 29, 2026
Missing Authentication for Critical Function in Hitachi Energy RTU500 series CMU firmware
An authentication bypass vulnerability in the firmware update endpoint of Hitachi Energy RTU500 end-of-life versions allows an unauthenticated attacker to upload arbitrary firmware through a crafted POST request. Successful exploitation could allow the attacker to modify device functionality or compromise the integrity or availability of the device.
CVE-2026-7395
High · 8.5
CWE-306 Sep 29, 2026
Missing Authentication for Critical Function in Hitachi Energy Asset Suite
Asset Suite allows unauthenticated users to access HTTPPublishAdapterTestServlet that can be used for configuration file upload, leading to information disclosure and integrity compromise. The HTTPPublishAdapterTestServlet is specifically meant for testing purposes to be used in a non-production environment.
CVE-2026-11796
Medium · 5.1
CWE-306 Sep 29, 2026
Missing Authentication for Critical Function in Hitachi Energy Asset Suite
Asset Suite allows unauthenticated users to access PropertiesReloadServlet, CacheFlushServlet, MetadataCacheFlushServlet and ResourceBundleReloadServlet, which could result in denial-of-service conditions affecting application availability. These servlets are designed to perform specific functions within production environment depending on how the Asset Suite application is configured.
CVE-2026-9854
High · 7.8
CWE-303 Sep 3, 2026
A vulnerability exists in SYS600 RBAC mechanism where users having access to the…
A vulnerability exists in SYS600 RBAC mechanism where users having access to the engineering tools could elevate their privileges to administrator level on the underlying Windows host, granting themselves full control over the host machine.
CVE-2026-9853
High · 7.8
CWE-303 Sep 3, 2026
A vulnerability exists in SYS600 which allows any user authenticated to the operating…
A vulnerability exists in SYS600 which allows any user authenticated to the operating system of the server hosting the application to read and modify application objects without being authenticated to the SYS600 system itself.
Only the SYS600 system users should be permitted to view and modify application objects.
CVE-2026-9852
High · 7.8
CWE-1236 Sep 3, 2026
CSV Injection in Hitachi Energy Microscada X Sys600
A CSV injection vulnerability exists in SYS600. Injected malicious formulas can add or modify data to the spreadsheet, insert links, exfiltrate data, and in some cases, depending on how the user has their environment configured, execute malicious code on the user’s machine. To exploit this issue attackers would need a way to create arbitrary log messages. This could be achieved through normal functionality via SCIL scripts, a log injection vulnerability, or via the SYS600 broker. This vulnerability affects all Windows users regardless of their privilege level who can run the Notify service and export the log.
CVE-2026-17539
Medium · 5.9
CWE-476 Sep 3, 2026
NULL Pointer Dereference in Hitachi Energy RTU500 series CMU firmware
RTU500 has a vulnerability, where high-load scenarios, such as sending GI requests at short intervals, may cause a NULL pointer dereference in the last entry of the enhanced message queue. This can cause a BCI_IEC104 fatal write error, resulting in connection interruption and restart, and ultimately a denial of service for bidirectional IEC 60870-5-104 communication.
CVE-2026-10763
High · 7.0
Jun 30, 2026
PROMOD V is using insecure HTTP communication instead of HTTPS. The vulnerability is due…
PROMOD V is using insecure HTTP communication instead of HTTPS. The vulnerability is due to the lack of HTTPS support from 3rd party Digipede server.
CVE-2026-8479
Medium · 6.9
CWE-476 May 26, 2026
NULL Pointer Dereference in Hitachi Energy RTU500 series CMU firmware
IEC 60870-5-104 used in bidirectional mode in RTU500 is vulnerable
for a NULL pointer dereferencing, if a specially crafted
sequence of messages is sent for a certain time, causing
Denial of Service impact.
Product is only affected if IEC 60870-5-104 functionality in
bidirectional mode (BCI) is configured.
CVE-2026-7310
Medium · 4.4
CWE-122 May 26, 2026
Heap-based Buffer Overflow in Hitachi Energy MACH HiDraw
A heap-based buffer overflow vulnerability exists in XML
parser functionality in the HiDraw. An authenticated
malicious user with local access can exploit this
vulnerability using a specially crafted XML file which may
lead to memory corruption and potential arbitrary code
execution. Successful exploitation could result in
application crashes (denial of service) and compromise the
confidentiality and integrity of the affected system.
CVE-2026-2460
High · 8.1
CWE-267 Feb 24, 2026
A vulnerability exists in REB500 for an authenticated user with low-level privileges to…
A vulnerability exists in REB500 for an authenticated user with low-level privileges to access and alter the content of directories by using the DAC protocol that the user is not authorized to do so.
CVE-2026-2459
High · 8.1
CWE-267 Feb 24, 2026
A vulnerability exists in REB500 for an authenticated user with Installer role to access…
A vulnerability exists in REB500 for an authenticated user with Installer role to access and alter the contents of directories that the role is not authorized to do so.
CVE-2026-1773
High · 7.5
CWE-184 Feb 24, 2026
IEC 60870-5-104 used in RTU500: Potential Denial of Service impact on reception of…
IEC 60870-5-104 used in RTU500: Potential Denial of Service impact on reception of invalid U-format frame. Product is only affected if IEC 60870-5-104 bi-directional functionality is configured. Enabling secure communication following IEC 62351-3 does not remediate the vulnerability but mitigates the risk of exploitation.
CVE-2026-1772
Medium · 5.3
CWE-280 Feb 24, 2026
RTU500 web interface: An unprivileged user can read user management information. The…
RTU500 web interface: An unprivileged user can read user management information. The information cannot be accessed via the RTU500 web user interface but requires further tools like browser development utilities to access them without required privileges.
CVE-2025-7740
High · 8.8
CWE-1392 Jan 28, 2026
Use of default credentials vulnerability in Hitachi Energy SuprOS product
Default credentials vulnerability exists in SuprOS
product. If exploited, this could allow an authenticated
local attacker to use an admin account created during
product deployment.
CVE-2025-1038
High · 7.5
CWE-78 Oct 28, 2025
OS Command Injection in Hitachi Energy TropOS 4th Gen
The “Diagnostics Tools” page of the web-based configuration utility does not properly validate user-controlled input, allowing an authenticated user with high privileges to inject commands into the command shell of the TropOS 4th Gen device. The injected commands can be exploited to execute several set-uid (SUID) applications to ultimately gain root access to the TropOS device.
CVE-2025-1037
High · 7.5
CWE-269 Oct 28, 2025
Improper Privilege Management in Hitachi Energy TropOS 4th Gen
By making minor configuration changes to the TropOS 4th Gen device, an authenticated user with the ability to run user level shell commands can enable access via secure shell (SSH) to an unrestricted root shell. This is possible through abuse of a particular set of scripts and executables that allow for certain commands to be run as root from an unprivileged context.
CVE-2025-1036
High · 8.7
CWE-78 Oct 28, 2025
OS Command Injection in Hitachi Energy TropOS 4th Gen
Command injection vulnerability exists in the “Logging” page of the web-based configuration utility. An authenticated user with low privileged network access for the configuration utility can execute arbitrary commands on the underlying OS to obtain root SSH access to the TropOS 4th Gen device.