Vivotek vulnerabilities
Published CVEs affecting Vivotek products: 12 record(s), with severity, exploitation and fixes.
Fd8136 Firmware 6Ip7137 Firmware 4IP7137 4Affected device model numbers are FD7131-VVTK,FD7131-VVTK,FD7131-VVTK,FD7141-VVTK,IP7131-VVTK,IP7133-VVTK,IP7133-VVTK,IP7133-VVTK,IP7134-VVTK,IP7135-VVTK,IP7135 1Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381 1
CVE-2026-35718
Medium · 6.5
CWE-22 Jun 2, 2026
Path Traversal in Vivotek Fd8136 Firmware
A path traversal vulnerability in the /admin/downloadMedias.cgi endpoint of VIVOTEK INC FD8136-VVTK firmware 0300a allows authenticated attackers to read any file on the device via sending a crafted request.
CVE-2026-35716
Medium · 6.3
CWE-121 Jun 2, 2026
Stack-based Buffer Overflow in Vivotek Fd8136 Firmware
A stack-based buffer overflow in the motion_privacy.cgi binary in VIVOTEK FD8136 firmware FD8136-VVTK-0300a allows authenticated remote attackers to execute arbitrary code as root via an oversized n1 parameter in a POST request to the /cgi-bin/admin/setpm.cgi, /cgi-bin/admin/setmd.cgi, or /cgi-bin/admin/setmd_profile.cgi endpoint (all symlinks to the same binary). The parameter value is copied into a fixed-size 0xa4-byte stack buffer without bounds checking, overwriting the saved link register. The binary is compiled without stack canaries.
CVE-2026-30652
High · 8.8
CWE-120 Jun 2, 2026
Classic Buffer Overflow in Vivotek Fd8136 Firmware
A remote buffer overflow vulnerability exists in the /cgi-bin/dido/setdo.cgi endpoint of the admin interface of Vivotek FD8136 cameras running firmware version FD8136-VVTK-0300a. This flaw allows an authenticated attacker to execute arbitrary code as root on the device.
CVE-2026-30650
High · 8.8
CWE-120 Jun 2, 2026
Classic Buffer Overflow in Vivotek Fd8136 Firmware
A post-authentication remote buffer overflow vulnerability exists in the /cgi-bin/admin/eventtask.cgi endpoint of the admin interface of Vivotek FD8136 cameras running firmware version FD8136-VVTK-0300a. This flaw allows an authenticated attacker to execute arbitrary code as root on the device remotely.
CVE-2026-30649
High · 7.3
CWE-121 Jun 2, 2026
Stack-based Buffer Overflow in Vivotek Fd8136 Firmware
Buffer Overflow vulnerability in VIVOTEK INC FD8136-VVTK-0300a allows a remote attacker to execute arbitrary code via the set_getparam.cgi component
CVE-2026-35717
Medium · 6.3
CWE-121 Jun 2, 2026
Stack-based Buffer Overflow in Vivotek Fd8136 Firmware
A stack-based buffer overflow in the export_language.cgi binary in VIVOTEK FD8136 firmware FD8136-VVTK-0300a allows authenticated remote attackers to execute arbitrary code as root via a crafted POST request to the /cgi-bin/admin/export_language.cgi endpoint. The handler passes the attacker-controlled Content-Length value directly to fread() as the read size into a fixed-size 0x60-byte stack buffer, overwriting the saved link register. The binary is compiled without stack canaries.
CVE-2026-22755
Critical · 9.3
CWE-77 Jan 13, 2026
Legacy Vivotek Camera Firmware Command Injection in upload_map.cgi
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330 (Firmware modules) allows OS Command Injection.This issue affects Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330: 0100a, 0106a, 0106b, 0107a, 0107b_1, 0109a, 0112a, 0113a, 0113d, 0117b, 0119e, 0120b, 0121, 0121d, 0121d_48573_1, 0122e, 0124d_48573_1, 012501, 012502, 0125c.
CVE-2025-66052
High · 7.2
CWE-78 Jan 9, 2026
Command injection in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,
The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
CVE-2025-66051
Medium · 6.5
CWE-22 Jan 9, 2026
Path traversal in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default.
The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
CVE-2025-66050
Critical · 9.8
CWE-1393 Jan 9, 2026
No password set for administrative account in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need.
The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
CVE-2025-66049
High · 7.5
CWE-306 Jan 9, 2026
Unprotected RTSP stream in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security.
The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
CVE-2025-12592
Critical · 9.3
CWE-1392 Nov 19, 2025
Use of default login credentials in Legacy Vivotek Devices
Legacy Vivotek Device firmware uses default credetials for the root and user login accounts.