CVE-2025-14095 — Privilege boundary violation in Radiometer Products
A "Privilege boundary violation" vulnerability is identified affecting multiple Radiometer Products. Exploitation of this vulnerability gives a user with physical access to the analyzer, the possibility to gain unauthorized access to functionalities outside the restricted environment. The vulnerability is due to weakness in the design of access control implementation in application software. Other related CVE's are CVE-2025-14096 & CVE-2025-14097. Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency. Required configuration for Exposure: Physical access to the analyzer is needed. Temporary work Around: Only authorized people can physically access the analyzer. Permanent solution: Local Radiometer representatives will contact all affected customers to discuss a permanent solution. Exploit Status: Researchers have provided working proof-of-concept. Radiometer is not aware of any publicly available exploit at the time of publication. Note: CVSS score 6.8 when underlying OS is Windows 7 or Windows XP Operating systems and CVSS score 5.7 when underlying OS is Windows 8 or Windows 10 operating systems.
Who exploits it and how urgent it is
A 0–100 score combining confirmed exploitation, ransomware and APT use, public exploits, EPSS and severity.
How the score was calculated
- EPSS 0.2% (30-day exploitation probability)+1
- Technical severity (medium)+3
The score orders the patch queue; it does not replace your asset context (internet exposure, criticality, compensating controls).
Triage
Is it exploited, how likely is exploitation, what does it touch, and how severe do the sources call it.
CISA SSVC assessment CISA
Three decision points CISA publishes for the CVEs it assesses (SSVC 2.0.3). A stakeholder decision, not a severity score.
Remediation
Fixes and mitigations documented by the sources — linked to the original advisory.
No fix documented by the sources we poll. That does not mean none exists: check the vendor advisory.
First 24 hours
Ordered from the record’s own fields — exposure first, because you cannot patch what you have not found. A rule-generated starting point.
- Identify exposed assets running the affected vendor/product/version combinations (Radiometer Medical Aps ABL800 BASIC and ABL800 FLEX analyzers, Radiometer Medical Aps ABL9 Analyzers, Radiometer Medical Aps ABL90 FLEX and ABL90 FLEX PLUS Analyzers…).
- No fix documented in the sources: reduce exposure and monitor the vendor advisory.
- Search available logs for exploit probes matching the vulnerability class (access control), errors and authentication anomalies.
Affected scope
Vendor, product and versions as the sources word them.
| Vendor | Product | Versions | Status | Source |
|---|---|---|---|---|
| Radiometer Medical Aps | ABL800 BASIC and ABL800 FLEX analyzers | version Application software versions < 6.20 MR2 with Windows 7, Windows XP as underlyinversion Application software versions < 6.20 MR2 with Windows 10 as underlying OS | Vulnerable | CVE Program (cve.org) e CISA ADP |
| Radiometer Medical Aps | ABL9 Analyzers | version Application software versions < 1.5.0 | Vulnerable | CVE Program (cve.org) e CISA ADP |
| Radiometer Medical Aps | ABL90 FLEX and ABL90 FLEX PLUS Analyzers | version All application software versions with Windows 7, Windows XP as underlying OSversion Application software versions < 3.5MR11 with Windows 10 as underlying OS | Vulnerable | CVE Program (cve.org) e CISA ADP |
| Radiometer Medical Aps | AQT90 FLEX Analyzers | version All Application software versions <= 8.13 MR2 | Vulnerable | CVE Program (cve.org) e CISA ADP |
Attack characteristics
The CVSS vector, decoded. It describes the attack, not your exposure to it.
Every base score collected
Sources score independently and may disagree; each row says who scored it and under which version.
| Score | Version | Severity | Expl. | Impact | Scored by |
|---|---|---|---|---|---|
| 6.8 | CVSS 3.1 | Medium | 0.9 | 5.9 | 46b595e9-1acc-41cb-9398-adaf98d37a9b via NIST National Vulnerability Database |
| 6.8 | CVSS 3.1 | Medium | — | — | Radiometer via CVE Program (cve.org) e CISA ADP |
| 5.7 | CVSS 3.1 | Medium | — | — | Radiometer via CVE Program (cve.org) e CISA ADP |
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H (score shown at the top: 46b595e9-1acc-41cb-9398-adaf98d37a9b) Weakness MITRE
Weakness class according to MITRE’s CWE catalog.
EPSS over time FIRST
Oct 13, 2026 → Oct 15, 2026 · 3 reading(s) · max 0.17%
Detection
Read off the CVSS vector and the weakness class. Starting points, not tested rules.
- Local/physical vector: focus on endpoint telemetry (EDR) from affected hosts.
- Audit administrative actions and access to resources outside each user’s normal pattern.
Timeline
What happened to this CVE, newest first.
- 2026
- Affected products added · radiometer medical aps/abl90 flex and abl90 flex plus analyzers, radiometer medical aps/aqt90 flex analyzers, radiometer
- SSVC assessment updated
- Record published
- CVSS changed · 6.8
- Source status changed · → Deferred
- Record created in this database
- 2025
- CVE published
Source activity
Repeated readings are counted rather than listed.
- 1× Official description updated · Oct 13, 2026 – Oct 13, 2026
References
1 on the record
Elsewhere on this site
Related CVEs (same products)
- High CVE-2025-14097 Remote Code Execution Vulnerability in Radiometer Products Dec 17, 2025
- High CVE-2025-14096 Credential Disclosure vulnerability in Radiometer Products Dec 17, 2025
Not in any source we poll
Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.
- No fixed version, patch or mitigation documented.
- No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
- No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
- No exploit packet captures, log samples, or incident case IDs supplied.
Answered from this record
Text assembled only from the fields above — no additional claims.
What should defenders know first?
CVE-2025-14095 is "Privilege boundary violation in Radiometer Products", rated Medium. It affects ABL800 BASIC and ABL800 FLEX analyzers (Radiometer Medical Aps); versions are in the scope table. It is not in CISA KEV, which does not rule out exploitation. CVSS 6.8 describes technical severity. EPSS 0.17% estimates the probability of exploitation in 30 days; neither replaces your asset context. First verify whether exposed or business-critical assets run the affected versions, apply vendor fixes or mitigations, and preserve logs for review.