CVE Intelligence
Medium Cryptography

CVE-2026-24441 — Tenda AC7 Transmits Admin Credentials Without HTTPS Protection

Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose account credentials in plaintext within HTTP responses, allowing an on-path attacker to obtain sensitive authentication material.

Published Feb 3, 2026 · Updated Oct 13, 2026 · Sources: NIST National Vulnerability Database, CVE Program (cve.org) e CISA ADP · CNA: VulnCheck

Who exploits it and how urgent it is

A 0–100 score combining confirmed exploitation, ransomware and APT use, public exploits, EPSS and severity.

No exploitation signal in the sources consulted so far.
How the score was calculated
  • EPSS 0.2% (30-day exploitation probability)+2
  • Technical severity (medium)+3

The score orders the patch queue; it does not replace your asset context (internet exposure, criticality, compensating controls).

Triage

Is it exploited, how likely is exploitation, what does it touch, and how severe do the sources call it.

Exploitation
Not confirmed
Not in CISA KEV — an absence of record, not proof it is unexploited.
EPSS FIRST
0.23%
ahead of 13% of scored CVEs · Oct 14, 2026
Affects
Shenzhen Tenda Technology Co., Ltd.
Tenda AC7 and 1 more
CVSS base
5.9
Medium · 3 source(s)

CISA SSVC assessment CISA

Three decision points CISA publishes for the CVEs it assesses (SSVC 2.0.3). A stakeholder decision, not a severity score.

Exploitation
None
none · proof-of-concept · active
Automatable
No
can an attacker script the kill-chain steps
Technical impact
Partial
partial · total control of the vulnerable component

Remediation

Fixes and mitigations documented by the sources — linked to the original advisory.

No fix documented by the sources we poll. That does not mean none exists: check the vendor advisory.

First 24 hours

Ordered from the record’s own fields — exposure first, because you cannot patch what you have not found. A rule-generated starting point.

  1. Identify exposed assets running the affected vendor/product/version combinations (Shenzhen Tenda Technology Co., Ltd. Tenda AC7, Tenda Ac7 Firmware).
  2. The attack is network-based and needs no privileges: restrict exposure (ACLs, VPN, WAF) until patched.
  3. No fix documented in the sources: reduce exposure and monitor the vendor advisory.
  4. Search available logs for exploit probes matching the vulnerability class (cryptography), errors and authentication anomalies.

Affected scope

Vendor, product and versions as the sources word them.

VendorProductVersionsStatusSource
Shenzhen Tenda Technology Co., Ltd. Tenda AC7 ≤ 03.03.03.01_cn Vulnerable CVE Program (cve.org) e CISA ADP
Tenda Ac7 Firmware ≤ 03.03.03.01 Vulnerable NIST National Vulnerability Database

Attack characteristics

The CVSS vector, decoded. It describes the attack, not your exposure to it.

Attack vector
Network
Attack complexity
High
Privileges required
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

Every base score collected

Sources score independently and may disagree; each row says who scored it and under which version.

ScoreVersionSeverityExpl.ImpactScored by
8.2 CVSS 4.0 High — — disclosure@vulncheck.com via NIST National Vulnerability Database
8.2 CVSS 4.0 High — — VulnCheck via CVE Program (cve.org) e CISA ADP
5.9 CVSS 3.1 Medium 2.2 3.6 nvd@nist.gov via NIST National Vulnerability Database
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N (score shown at the top: nvd@nist.gov)

Weakness MITRE

Weakness class according to MITRE’s CWE catalog.

CWE-319 · Cleartext Transmission of Sensitive Information

Other CVEs with this weakness →

EPSS over time FIRST

Oct 13, 2026 → Oct 14, 2026 · 2 reading(s) · max 0.23%

Detection

Read off the CVSS vector and the weakness class. Starting points, not tested rules.

  • Prioritize edge telemetry for the network-reachable component (proxy, WAF, IDS/IPS).
  • Check TLS negotiations and unexpected certificates in the component’s traffic.
web/proxy/WAF logsnetwork IDS/IPS

Timeline

What happened to this CVE, newest first.

  • 2026
  • Affected products added · shenzhen tenda technology co., ltd./tenda ac7
    Oct 13, 2026 · CVE Program (cve.org) e CISA ADP
  • SSVC assessment updated
    Oct 13, 2026 · CVE Program (cve.org) e CISA ADP
  • Record published
    Oct 13, 2026
  • CVSS changed · 5.9
    Oct 13, 2026 · NIST National Vulnerability Database
  • Source status changed · → Analyzed
    Oct 13, 2026 · NIST National Vulnerability Database
  • Record created in this database
    Oct 13, 2026 · NIST National Vulnerability Database
  • CVE published
    Feb 3, 2026 · VulnCheck

Source activity

Repeated readings are counted rather than listed.

  • 1× Official description updated · Oct 13, 2026 – Oct 13, 2026

References

2 on the record

Elsewhere on this site

Shenzhen Tenda Technology Co., Ltd.
every CVE for this vendor
Cryptography
same class
CWE-319
other pages naming this weakness

Related CVEs (same products)

  • Critical CVE-2026-51846 Tenda AC7 Firmware Stack Buffer Overflow in wanSpeed Parameter (CVE-2026-51846) Jun 19, 2026
  • Critical CVE-2026-51844 Tenda AC7 Stack Buffer Overflow in AdvSetMacMtuWan via cloneType Jun 19, 2026
  • Critical CVE-2026-51843 Tenda AC7 firmware stack buffer overflow in wanMTU handler Jun 19, 2026
  • Critical CVE-2026-51845 Tenda AC7 Stack-based Buffer Overflow in AdvSetMacMtuWan Interface Jun 19, 2026
  • High CVE-2026-4974 Tenda AC7 POST Request SetSysTimeCfg fromSetSysTime memory corruption Mar 27, 2026
  • Medium CVE-2026-24434 Tenda AC7 Web Interface Lacks CSRF Protections for Admin Actions Feb 3, 2026

Not in any source we poll

Listed rather than left blank: an empty field and an unmeasured one look identical on screen, and only one is a reason to look elsewhere.

  • No fixed version, patch or mitigation documented.
  • No confirmed IOCs, IP addresses, domains, file hashes, or malware artifacts supplied.
  • No organization-specific asset inventory, compensating-control status, or patch deployment evidence supplied.
  • No exploit packet captures, log samples, or incident case IDs supplied.

Answered from this record

Text assembled only from the fields above — no additional claims.

What should defenders know first?

CVE-2026-24441 is "Tenda AC7 Transmits Admin Credentials Without HTTPS Protection", rated Medium. It affects Tenda AC7 (Shenzhen Tenda Technology Co., Ltd.); versions are in the scope table. It is not in CISA KEV, which does not rule out exploitation. CVSS 5.9 describes technical severity. EPSS 0.23% estimates the probability of exploitation in 30 days; neither replaces your asset context. First verify whether exposed or business-critical assets run the affected versions, apply vendor fixes or mitigations, and preserve logs for review.

Comments

Moderated technical discussion. Read the community guidelines.

No comments yet.

Sign in or create an account to comment and suggest corrections.