Tenda Ac7 Firmware vulnerabilities
🔔 Create alert RSS Version checker
Published CVEs affecting Tenda Ac7 Firmware: 17 record(s), with affected versions and fixes.cpe:2.3:o:tenda:ac7_firmware
CVE-2026-51846
Critical · 9.8
CWE-121 Jun 19, 2026
Tenda AC7 Firmware Stack Buffer Overflow in wanSpeed Parameter (CVE-2026-51846)
In Tenda AC7 v15.03.06.44, the wanSpeed parameter of the route /goform/AdvSetMacMtuWan has a stack buffer overflow vulnerability that can lead to remote arbitrary code execution.
CVE-2026-51845
Critical · 9.8
CWE-121 Jun 19, 2026
Tenda AC7 Stack-based Buffer Overflow in AdvSetMacMtuWan Interface
Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the /goform/AdvSetMacMtuWan interface via the mac parameter.
CVE-2026-51844
Critical · 9.8
CWE-121 Jun 19, 2026
Tenda AC7 Stack Buffer Overflow in AdvSetMacMtuWan via cloneType
Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the /goform/AdvSetMacMtuWan interface via the cloneType parameter.
CVE-2026-51843
Critical · 9.8
CWE-121 Jun 19, 2026
Tenda AC7 firmware stack buffer overflow in wanMTU handler
Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the /goform/AdvSetMacMtuWan interface via the wanMTU parameter.
CVE-2026-4974
High · 8.8
CWE-787 Mar 27, 2026
Tenda AC7 POST Request SetSysTimeCfg fromSetSysTime memory corruption
A flaw has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg of the component POST Request Handler. Executing a manipulation of the argument Time can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used.
CVE-2026-24441
Medium · 5.9
CWE-319 Feb 3, 2026
Tenda AC7 Transmits Admin Credentials Without HTTPS Protection
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose account credentials in plaintext within HTTP responses, allowing an on-path attacker to obtain sensitive authentication material.
CVE-2026-24434
Medium · 6.5
CWE-352 Feb 3, 2026
Tenda AC7 Web Interface Lacks CSRF Protections for Admin Actions
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior does not implement CSRF protections for administrative functions in the web management interface. The interface does not enforce anti-CSRF tokens or robust origin validation, which can allow an attacker to induce a logged-in administrator to perform unintended state-changing requests and modify router settings.
CVE-2026-24427
Medium · 5.5
CWE-201 Feb 3, 2026
Tenda AC7 Exposes Admin Credentials in Configuration Responses
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose sensitive information in web management responses. Administrative credentials, including the router and/or admin panel password, are included in plaintext within configuration response bodies. In addition, responses lack appropriate Cache-Control directives, which may permit web browsers to cache pages containing these credentials and enable subsequent disclosure to an attacker with access to the client system or browser profile.
CVE-2026-24426
Medium · 6.1
CWE-79 Feb 3, 2026
Tenda AC7 Reflected XSS via Web Interface Output Encoding
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior contain an improper output encoding vulnerability in the web management interface. User-supplied input is reflected in HTTP responses without adequate escaping, allowing injection of arbitrary HTML or JavaScript in a victim’s browser context.
CVE-2025-11586
Critical · 9.8
CWE-119 Oct 10, 2025
Tenda AC7 setNotUpgrade stack-based overflow
A vulnerability was determined in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/setNotUpgrade. This manipulation of the argument newVersion causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.
CVE-2025-11528
High · 8.8
CWE-119 Oct 9, 2025
Tenda AC7 saveAutoQos stack-based overflow
A vulnerability was identified in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/saveAutoQos. The manipulation of the argument enable leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
CVE-2025-11527
High · 8.8
CWE-119 Oct 9, 2025
Tenda AC7 fast_setting_pppoe_set stack-based overflow
A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing a manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.
CVE-2025-11526
High · 8.8
CWE-119 Oct 9, 2025
Tenda AC7 WifiMacFilterSet stack-based overflow
A vulnerability was found in Tenda AC7 15.03.06.44. The affected element is an unknown function of the file /goform/WifiMacFilterSet. Performing a manipulation of the argument wifi_chkHz results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used.
CVE-2025-11525
High · 8.8
CWE-119 Oct 8, 2025
Tenda AC7 SetUpnpCfg stack-based overflow
A vulnerability has been found in Tenda AC7 15.03.06.44. Impacted is an unknown function of the file /goform/SetUpnpCfg. Such manipulation of the argument upnpEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-11524
High · 8.8
CWE-119 Oct 8, 2025
Tenda AC7 SetDDNSCfg stack-based overflow
A flaw has been found in Tenda AC7 15.03.06.44. This issue affects some unknown processing of the file /goform/SetDDNSCfg. This manipulation of the argument ddnsEn causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been published and may be used.
CVE-2025-11523
High · 8.8
CWE-77 Oct 8, 2025
Tenda AC7 AdvSetLanip command injection
A vulnerability was detected in Tenda AC7 15.03.06.44. This vulnerability affects unknown code of the file /goform/AdvSetLanip. The manipulation of the argument lanIp results in command injection. It is possible to launch the attack remotely. The exploit is now public and may be used.
CVE-2018-14558
Critical · 9.8
KEV High · 62 CWE-78 Oct 30, 2018
Tenda AC7, AC9, and AC10 Routers Command Injection Vulnerability
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input.