Schneider Electric vulnerabilities
Published CVEs affecting Schneider Electric products: 49 record(s), with severity, exploitation and fixes.
Powerchute Serial Shutdown 11EcoStruxure™ IT Data Center Expert (Formerly known as StruxureWare Data Center Expert) 3Powerlogic P7 Firmware 3PowerLogic™ P7 3Saitel DP Remote Terminal Unit & Controller 3EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller 3Struxureware Data Center Expert 2EcoStruxure Building Operation Workstation 2Ecostruxure Power Build - Rapsody 2Easylogic T150 Firmware 2Saitel Dp Firmware 2PowerLogic™ T300 2SCADAPack 47x 2SCADAPack 47xi 2SCADAPack 57x 2NetBotz 5 - 750/755 2Saitel DR RTU 2Saitel DP RTU 2EcoStruxure Building Operation Webstation 2Modicon M251 Firmware 2Modicon M241 Firmware 2Ecostruxure Power Operation 2Easergy MiCOM P443, P445, P446, P543, P544, P545, P546 1Easergy MiCOM P849 1Easergy MiCOM P841 1Easergy MiCOM P746 1Easergy MiCOM P741, P742, P743 1Easergy MiCOM P643 1Easergy MiCOM P642, P645 1PowerLogic™ T500 1Easergy MiCOM P442, P444 1Easergy MiCOM P342, P343, P344, P345 1Easergy MiCOM P341 1Easergy MiCOM P24x 1Easergy MiCOM P14x 1EasyLogic T150 (formerly Saitel DR) 1Saitel DP 1Modicon M262 Firmware 1Modicon Controllers M241/M251 1Modicon Controllers M258/LMC058 1
CVE-2026-2404
Medium · 5.3
CWE-116 Apr 14, 2026
Improper Encoding or Escaping of Output in Schneider Electric Powerchute Serial Shutdown
CWE-116 Improper Encoding or Escaping of Output vulnerability exists that could cause log injection and forged log when an attacker alters the POST /j_security check request payload.
CVE-2026-2403
Medium · 4.3
CWE-1284 Apr 14, 2026
CWE-1284 Improper Validation of Specified Quantity in Input vulnerability exists that…
CWE-1284 Improper Validation of Specified Quantity in Input vulnerability exists that could cause Event and Data Log truncation impacting log integrity when a Web Admin user alters the POST /logsettings request payload.
CVE-2026-2402
Medium · 5.3
CWE-307 Apr 14, 2026
Improper Restriction of Excessive Authentication Attempts in Schneider Electric Powerchute Serial Shutdown
CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on a sequence of requests to multiple endpoints.
CVE-2026-2401
Medium · 5.0
CWE-532 Apr 14, 2026
Insertion of Sensitive Information into Log File in Schneider Electric Powerchute Serial Shutdown
CWE-532 Insertion of Sensitive Information into Log File vulnerability exists that could cause confidential information to be exposed when a Web Admin user executes a malicious file provided by an attacker.
CVE-2026-2400
Medium · 4.3
CWE-93 Apr 14, 2026
CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection') vulnerability exists…
CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection') vulnerability exists that could cause application user credentials to reset when a Web Admin user alters the POST /setPCBEDesc request payload.
CVE-2026-2399
Medium · 6.1
CWE-22 Apr 14, 2026
Path Traversal in Schneider Electric Powerchute Serial Shutdown
CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause critical files overwritten with text data when a Web Admin user alters the POST /REST/upssleep request payload.
CVE-2026-2273
High · 8.2
CWE-94 Mar 10, 2026
Code Injection in Schneider Electric Ecostruxure Automation Expert
CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the workstation and a potential loss of Confidentiality, Integrity and Availability of the subsequent system when an authenticated user opens a malicious project file.
CVE-2026-1286
Medium · 6.5
CWE-502 Mar 10, 2026
Deserialization of Untrusted Data in Schneider Electric Ecostruxure Foxboro Dcs Control Software
CWE-502: Deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on workstation when an admin authenticated user opens a malicious project file.
CVE-2025-13957
High · 7.5
CWE-798 Mar 10, 2026
Use of Hard-coded Credentials in Schneider Electric EcoStruxure™ IT Data Center Expert (Formerly known as StruxureWare Data Center Expert)
CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator credentials and PostgreSQL database credentials are known. SOCKS Proxy is disabled by default.
CVE-2025-13902
Medium · 5.4
CWE-79 Mar 10, 2026
Cross-site Scripting (XSS) in Schneider Electric Modicon M258 Firmware
CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload.
CVE-2025-13901
Medium · 5.3
CWE-404 Mar 10, 2026
Improper Resource Shutdown or Release in Schneider Electric Modicon M241 Firmware
CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels.
CVE-2025-11739
High · 7.8
CWE-502 Mar 10, 2026
Deserialization of Untrusted Data in Schneider Electric Ecostruxure Power Monitoring Expert
CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization.
CVE-2026-1227
High · 7.0
CWE-611 Feb 11, 2026
XML External Entity (XXE) in Schneider Electric EcoStruxure Building Operation Workstation
CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized disclosure of local files, interaction within the EBO system, or denial of service conditions when a local user uploads a specially crafted TGML graphics file to the EBO server from Workstation.
CVE-2026-1226
High · 7.0
CWE-94 Feb 11, 2026
Code Injection in Schneider Electric EcoStruxure Building Operation Workstation
CWE‑94: Improper Control of Generation of Code vulnerability exists that could cause execution of untrusted or unintended code within the application when maliciously crafted design content is processed through a TGML graphics file.
CVE-2025-13905
High · 7.0
CWE-276 Jan 29, 2026
Incorrect Default Permissions in Schneider Electric EcoStruxure™ Process Expert
CWE-276: Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse shell when one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart.
CVE-2025-13845
High · 7.8
CWE-416 Jan 15, 2026
Use After Free in Schneider Electric Ecostruxure Power Build - Rapsody
CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody.
CVE-2025-13844
Medium · 5.3
CWE-415 Jan 15, 2026
Double Free in Schneider Electric Ecostruxure Power Build - Rapsody
CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker into Rapsody.
CVE-2025-11567
High · 7.3
CWE-276 Nov 12, 2025
CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system...
CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured.
CVE-2025-11566
Medium · 6.9
CWE-307 Nov 12, 2025
CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that...
CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on the local network to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on the /REST/shutdownnow endpoint.
CVE-2025-11565
High · 7.3
CWE-22 Nov 12, 2025
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')...
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause elevated system access when a Web Admin user on the local network tampers with the POST /REST/UpdateJRE request payload.
CVE-2025-9997
Medium · 5.8
CWE-78 Sep 9, 2025
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'...
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session.
CVE-2025-9996
Medium · 5.8
CWE-78 Sep 9, 2025
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'...
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause the execution of any shell command when executing a netstat command using BLMon Console in an SSH session.
CVE-2018-7841
Critical · 9.8
KEV Urgent · 75 Public exploit CWE-89 May 22, 2019
Schneider Electric U.motion Builder SQL Injection Vulnerability
A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an improper set of characters is entered.
CVE-2018-2811
High · 7.7
Apr 18, 2018
Vulnerability in the Java SE component of Oracle Java SE (subcomponent: Install). Supported...
Vulnerability in the Java SE component of Oracle Java SE (subcomponent: Install). Supported versions that are affected are Java SE: 8u162 and 10. Difficult to exploit vulnerability allows unauthenticated attacker with logon to the infrastructure where Java SE executes to compromise Java SE. Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Java SE, attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Java SE. Note: Applies to installation process on client deployment of Java. CVSS 3.0 Base Score 7.7 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H).